Development and preliminary evaluation of an ultrasonic motor actuated needle guide for 3T MRI-guided transperineal prostate interventions

Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.

[1]  Alexandru Patriciu,et al.  “MRI Stealth” robot for prostate interventions , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[2]  C. N. Coleman,et al.  System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner , 2004, Magnetic resonance in medicine.

[3]  Gabor Fichtinger,et al.  An MRI-Compatible Robotic System With Hybrid Tracking for MRI-Guided Prostate Intervention , 2011, IEEE Transactions on Biomedical Engineering.

[4]  Jan J W Lagendijk,et al.  MRI-guided robotic system for transperineal prostate interventions: proof of principle , 2010, Physics in medicine and biology.

[5]  Hao Su,et al.  Real-time MRI-guided needle placement robot with integrated fiber optic force sensing , 2011, 2011 IEEE International Conference on Robotics and Automation.

[6]  Jurgen J Fütterer,et al.  Imaging modalities for prostate cancer , 2009, Expert review of anticancer therapy.

[7]  Gabor Fichtinger,et al.  Integrated system for robot-assisted in prostate biopsy in closed MRI scanner , 2008, 2008 IEEE International Conference on Robotics and Automation.

[8]  A. D'Amico,et al.  Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer. , 1998, International journal of radiation oncology, biology, physics.

[9]  Katarzyna J Macura,et al.  MR-guided biopsy of the prostate: an overview of techniques and a systematic review. , 2008, European urology.

[10]  C. N. Coleman,et al.  Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner. , 2006, The Journal of urology.

[11]  H. Hricak,et al.  Imaging of prostate cancer. , 2007, Radiologic clinics of North America.

[12]  Gabor Fichtinger,et al.  Integrated navigation and control software system for MRI-guided robotic prostate interventions , 2010, Comput. Medical Imaging Graph..

[13]  A. D'Amico,et al.  Transperineal magnetic resonance image guided prostate biopsy. , 2000, The Journal of urology.

[14]  R Kikinis,et al.  Robot-assisted needle placement in open MRI: System architecture, integration and validation , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[15]  Gabor Fichtinger,et al.  Design of a novel MRI compatible manipulator for image guided prostate interventions , 2005, IEEE Transactions on Biomedical Engineering.

[16]  C. N. Coleman,et al.  MRI-guided HDR prostate brachytherapy in standard 1.5T scanner. , 2004, International journal of radiation oncology, biology, physics.

[17]  Tom W J Scheenen,et al.  Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidance. , 2011, Radiology.

[18]  A.A. Goldenberg,et al.  Robotic System for Closed-Bore MRI-Guided Prostatic Interventions , 2008, IEEE/ASME Transactions on Mechatronics.

[19]  G.S. Fischer,et al.  MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement , 2008, IEEE/ASME Transactions on Mechatronics.

[20]  Gabor Fichtinger,et al.  Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches , 2010, 2010 IEEE International Conference on Robotics and Automation.

[21]  J C Presti,et al.  Prostate cancer: assessment of risk using digital rectal examination, tumor grade, prostate-specific antigen, and systematic biopsy. , 2000, Radiologic clinics of North America.

[22]  Gabor Fichtinger,et al.  A preliminary analysis and model of prostate injection distributions , 2006, The Prostate.

[23]  B. Kiefer,et al.  Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device , 2006, European Radiology.

[24]  Thomas Hambrock,et al.  Thirty-Two-Channel Coil 3T Magnetic Resonance-Guided Biopsies of Prostate Tumor Suspicious Regions Identified on Multimodality 3T Magnetic Resonance Imaging: Technique and Feasibility , 2008, Investigative radiology.

[25]  Gabor Fichtinger,et al.  Preliminary evaluation of a MRI-compatible modular robotic system for MRI-guided prostate interventions , 2010, 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[26]  J. Blasko,et al.  Brachytherapy for carcinoma of the prostate: techniques, patient selection, and clinical outcomes. , 2002, Seminars in radiation oncology.

[27]  J Kurhanewicz,et al.  Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology. , 2000, The Journal of urology.