A Fault Detection and Protection Scheme for Three-Level DC–DC Converters Based on Monitoring Flying Capacitor Voltage

Fault detection and protection is an important design aspect for any power converter, especially in high-power high-voltage applications, where cost of failure can be high. The three-level dc-dc converter and its varied derivatives are attractive topologies in high-voltage high-power converter applications. The protection method can not only prevent the system failure against unbalanced voltage stresses on the switches, but also provide a remedy for the system as faults occur and save the remaining components. The three-level converter is subject to voltage unbalance in certain abnormal conditions, which can result in switch overvoltage and system failure. The reasons for the unbalanced voltage stresses are fully investigated and categorized. The solutions to each abnormal condition are introduced. In addition to the voltage unbalance, the three-level converters can be protected against multiple faults by the proposed protection method through monitoring the flying capacitor voltage. Phenomena associated with each fault are thoroughly analyzed and summarized. The protection circuit is simple and can be easily implemented, while it can effectively protect the three-level converters and its derivatives, which has been verified by the experiment with a three-level parallel resonant converter.

[1]  Thomas A. Lipo,et al.  Fault protection in a multilevel inverter implementation of a static condenser , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[2]  Jianping Ying,et al.  Analysis and solution to voltage unbalance of the flying capacitor in ZVS three-level DC/DC converter , 2004, INTELEC 2004. 26th Annual International Telecommunications Energy Conference.

[3]  Cursino B. Jacobina,et al.  Detection and compensation of switch faults in a three level inverter , 2006 .

[4]  J.C. Balda,et al.  A Three-Level Full-Bridge Zero-Voltage Zero-Current Switching Converter With a Simplified Switching Scheme , 2007, 2007 IEEE Power Electronics Specialists Conference.

[5]  J.C. Balda,et al.  A Three-Level Full-Bridge Zero-Voltage Zero-Current Switching Converter With a Simplified Switching Scheme , 2009, IEEE Transactions on Power Electronics.

[6]  Qinghong Yu,et al.  Frequency Diagnostic Universal Fault Protection for Current Fed Parallel Resonant Electronic Ballast , 2007, IEEE Transactions on Power Electronics.

[7]  Nianci Huang,et al.  A Zero-Voltage and Zero-Current Switching Three-Level DC–DC Converter With Reduced Rectifier Voltage Stress and Soft-Switching-Oriented Optimized Design , 2006, IEEE Transactions on Power Electronics.

[8]  Xinbo Ruan,et al.  Zero-Voltage-Switching PWM Hybrid Full-Bridge Three-Level Converter With Secondary-Voltage Clamping Scheme , 2008, IEEE Transactions on Industrial Electronics.

[9]  Zhengyu Lu,et al.  Three-level LLC series resonant DC/DC converter , 2005, IEEE Transactions on Power Electronics.

[10]  W. Shen,et al.  Design and Implementation of High Power Density Three-Level Parallel Resonant Converter for Capacitor Charger , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[11]  Dragan Maksimovic,et al.  Overload Protection in Digitally Controlled DC-DC Converters , 2006 .

[12]  Hang-Seok Choi,et al.  Protection schemes for various fault conditions for off-line flyback converters , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[13]  Fred C. Lee,et al.  A zero-voltage and zero-current switching three-level DC/DC converter , 2002 .

[14]  J. R. Pinheiro,et al.  The three-level ZVS PWM converter-a new concept in high voltage DC-to-DC conversion , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.

[15]  Dong-Seok Hyun,et al.  Fault diagnosis and neutral point voltage control when the 3-level inverter faults occur , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[16]  Xinbo Ruan,et al.  Zero-Voltage-Switching Multiresonant Three-Level Converters , 2007, IEEE Transactions on Industrial Electronics.

[17]  Xinbo Ruan,et al.  An Improved ZVS PWM Three-Level Converter , 2004, IEEE Transactions on Industrial Electronics.

[18]  Jung-Ho Kim,et al.  The effective protection circuit in inverter microwave oven , 1999, ICECS'99. Proceedings of ICECS '99. 6th IEEE International Conference on Electronics, Circuits and Systems (Cat. No.99EX357).

[19]  A. Ioinovici,et al.  A zero-voltage and zero-current switching three-level DC-DC converter with reduced rectifier voltage stress , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[20]  Fred C. Lee,et al.  A high-power-density DC/DC converter for high-power distributed power systems , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[21]  Byeong-Mun Song,et al.  A three-level DC-DC converter with wide-input voltage operations for ship-electric-power-distribution systems , 2003, IEEE Transactions on Plasma Science.

[22]  C.R. Lee,et al.  Protection circuit for electronic ballasts at fluorescent lamp life-end , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[23]  Y. Jang,et al.  A new three-level soft-switched converter , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[24]  B. Li,et al.  Three-level converters-a new approach for high voltage and high power DC-to-DC conversion , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[25]  Xinbo Ruan,et al.  Zero-voltage-switching PWM three-level converter with two clamping diodes , 2002, IEEE Trans. Ind. Electron..

[26]  Xiaogao Xie,et al.  Analysis and Optimization of LLC Resonant Converter With a Novel Over-Current Protection Circuit , 2005, IEEE Transactions on Power Electronics.

[27]  Ho-Gi Kim,et al.  Fault Diagnosis of a ZVS DC–DC Converter Based on DC-Link Current Pulse Shapes , 2008, IEEE Transactions on Industrial Electronics.

[28]  Xinbo Ruan,et al.  Zero-voltage-switching PWM hybrid full-bridge three-level converter , 2005, IEEE Transactions on Power Electronics.

[29]  Francisco Venustiano,et al.  Novel DC/DC Converters For High-Power Distributed Power Systems , 2003 .