Formation and characteristics of negative stepped leaders in 4–10m long air gap discharges

Natural lightning flashes are stochastic and uncontrollable, and thus it is difficult to observe the formation process of a downward negative stepped leader (NSL) directly and in detail. In this paper, the formation processes of NSLs in controllable laboratorial long-air-gap discharge experiments were studies. First, a series of negative long-air-gap discharge experiments with scales of 4~10 m were designed and carried out. According to the observation results of these experiments, two kinds of formation processes for NSLs with different scales were presented, and several of the characteristic parameters, including the scale, the propagation velocity and the dark period, were obtained. By comparing these characteristics with that in natural flashes, the similarity between the NSLs in the simulation experiments and those in natural flashes was proved, and the actual formation of NSLs in natural flashes was deduced.

[1]  Basil Ferdinand Jamieson Schonland,et al.  Progressive lightning IV-The discharge mechanism , 1938 .

[2]  C. F. Wagner,et al.  Shielding of Transmission Lines , 1941, Transactions of the American Institute of Electrical Engineers.

[3]  K. Berger,et al.  Novel observations on lightning discharges: Results of research on Mount San Salvatore , 1967 .

[4]  T. Suzuki,et al.  Breakdown process in rod-to-plane gaps with negative switching impulses , 1975, IEEE Transactions on Power Apparatus and Systems.

[5]  I. Gallimberti,et al.  The mechanism of the long spark formation , 1979 .

[6]  Kunihiko Miyake,et al.  Discharge Path Model in Model Test of Lightning Strokes to Tall Mast , 1981, IEEE Transactions on Power Apparatus and Systems.

[7]  Martin A. Uman,et al.  Speed and current for lightning stepped leaders near ground as determined from electric field records , 1985 .

[8]  Vladislav Mazur,et al.  Triggered lightning strikes to aircraft and natural intracloud discharges , 1989 .

[9]  P. Ortega,et al.  Performance of a 16.7 m air rod-plane gap under a negative switching impulse , 1994 .

[10]  S. Okabe,et al.  Discharge characteristics of 5 m long air gap under foggy conditions with lightning shielding of transmission line , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  Xie Shi-jun Discharge Observation of Simulation Experiment on Increasing Lightning Shielding Efficiency of UHVAC Transmission Lines with Side Rod , 2010 .

[12]  Franco D'Alessandro,et al.  Attachment Processes and Influencing Factors in Competition Tests Under Switching Impulse Voltages , 2013, IEEE Transactions on Plasma Science.

[13]  J. Montanyà,et al.  The start of lightning: Evidence of bidirectional lightning initiation , 2015, Scientific Reports.