High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data.

PURPOSE In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, theoretically-exact helical CT is a viable option for high-resolution micro-CT imaging at high cone-angles (∼50°). The elevated cone-angle enables better utilization of the available X-ray flux and therefore shorter image acquisition time than conventional micro-CT systems. METHODS By using the theoretically-exact Katsevich 1PI inversion formula, we are not restricted to a low-cone-angle regime; we can in theory obtain artefact-free reconstructions from projection data acquired at arbitrary high cone-angles. However, this reconstruction method is sensitive to misalignments in the tomographic data, which result in geometric distortion and streaking artefacts. We use a parametric model to quantify the deviation between the actual acquisition trajectory and an ideal helix, and use an autofocus method to estimate the relevant parameters. We define optimal units for each parameter, and use these to ensure consistent alignment accuracy across different cone-angles and different magnification factors. The tomographic image is obtained from a set of virtual projections in which software correction for hardware misalignment has been applied. RESULTS We make significant modifications to the autofocus method that allow this method to be used in helical micro-CT reconstruction, and show that these developments enable theoretically-exact reconstruction from experimental data using the Katsevich 1PI (K1PI) inversion formula. We further demonstrate how autofocus-corrected, theoretically-exact helical CT reduces the image acquisition time by an order of magnitude compared to conventional circular scan micro-CT. CONCLUSIONS Autofocus-corrected, theoretically-exact cone-beam reconstruction is a viable option for reducing acquisition time in high-resolution micro-CT imaging. It also opens up the possibility of efficiently imaging long objects.

[1]  Alexander Sasov,et al.  Compensation of mechanical inaccuracies in micro-CT and nano-CT , 2008, Optical Engineering + Applications.

[2]  Pierre Grangeat Analyse d'un systeme d'imagerie 3d par reconstruction a partir de radiographies x en geometrie conique , 1987 .

[3]  C Axelsson,et al.  Three-dimensional reconstruction from cone-beam data in O(N3 log N) time. , 1994, Physics in medicine and biology.

[4]  Rolf Clackdoyle,et al.  A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection , 1994, IEEE Trans. Medical Imaging.

[5]  T Varslot,et al.  Reliable automatic alignment of tomographic projection data by passive auto-focus. , 2011, Medical physics.

[6]  Hengyong Yu,et al.  Studies on artifacts of the Katsevich algorithm for spiral cone-beam CT , 2004, SPIE Optics + Photonics.

[7]  Ge Wang,et al.  Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve. , 2004, Medical physics.

[8]  Hengyong Yu,et al.  A unified framework for exact cone-beam reconstruction formulas. , 2005, Medical physics.

[9]  Xiaochuan Pan,et al.  Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT. , 2004, Physics in medicine and biology.

[10]  Fei Yang,et al.  Fast Katsevich Algorithm Based on GPU for Helical Cone-Beam Computed Tomography , 2010, IEEE Transactions on Information Technology in Biomedicine.

[11]  A. Katsevich Analysis of an exact inversion algorithm for spiral cone-beam CT. , 2002, Physics in medicine and biology.

[12]  Alexander Katsevich,et al.  Theoretically Exact Filtered Backprojection-Type Inversion Algorithm for Spiral CT , 2002, SIAM J. Appl. Math..

[13]  Xiaochuan Pan,et al.  Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT. , 2004, Physics in medicine and biology.

[14]  A. Katsevich,et al.  Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography. , 2004, Physics in medicine and biology.

[15]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[16]  Jun Ni,et al.  A Parallel Implementation of the Katsevich Algorithm for 3-D CT Image Reconstruction , 2006, The Journal of Supercomputing.

[17]  Hsien-Hsin S. Lee,et al.  Optimizing Katsevich image reconstruction algorithm on multicore processors , 2007, 2007 International Conference on Parallel and Distributed Systems.

[18]  Andrew Kingston,et al.  An auto-focus method for generating sharp 3D tomographic images , 2010, Optical Engineering + Applications.

[19]  Abu-Bakr Al-Mehdi,et al.  Increased Depth of Cellular Imaging in the Intact Lung Using Far-Red and Near-Infrared Fluorescent Probes , 2006, Int. J. Biomed. Imaging.

[20]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.

[21]  Günter Lauritsch,et al.  Evaluation and empirical analysis of an exact FBP algorithm for spiral cone-beam CT , 2003, SPIE Medical Imaging.

[22]  Frédéric Noo,et al.  Exact helical reconstruction using native cone-beam geometries. , 2003, Physics in medicine and biology.

[23]  Tae-Sun Choi,et al.  Focusing techniques , 1992, Other Conferences.

[24]  Ming Jiang,et al.  Parallel Implementation of Katsevich's FBP Algorithm , 2006, Int. J. Biomed. Imaging.

[25]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .