Room air stratification in combined chilled ceiling and displacement ventilation systems

Radiant chilled ceilings with displacement ventilation (DV) represent a promising integrated system design that combines the energy efficiency of both sub-systems with the opportunity for improved ventilation performance resulting from the thermally stratified environment of DV systems. The purpose of this study was to conduct laboratory experiments for a typical U.S. interior zone office to investigate how room air stratification is affected by the ratio of cooling load removed by a chilled ceiling to the total cooling load, η, for two different chilled ceiling configurations. The experiments were carried out in a climatic chamber equipped with radiant panels installed in the suspended ceiling. In the first test configuration representative of thermally activated slab applications, 12 panels covering 73.5% of the ceiling were used. During the second series of tests, 6 panels covering 36.7% of the ceiling were used, representing a typical installation of metal radiant panels. The cooling load removed by the panels varied between 0 and 73 W/m2 (0–23.1 Btu/(h ft2)) (based on radiant panel area) or between 0 and 28 W/m2 (0–8.9 Btu/(h ft2)) (based on room area). The average mean water temperature of the panels varied over a more moderate range of 20°C–24°C (60°F–75.2°F) for the 12-panel tests and over a colder range of 16.5°C–22.6°C (61.7°F–72.7°F) for the 6-panel tests. The displacement ventilation airflow rate varied between 1.65 and 4.03 l/(s m2) (0.32–0.79 cfm/ft2), and the supply air temperature was kept constant at 18°C (64.4°F). The results showed that increasing η, the relative amount of the cooling load removed by the chilled ceiling, reduced the total room stratification. However, a comparison between the colder 6-panel tests and the warmer 12-panel tests indicated that average radiant surface temperature (mean chilled water temperature in panels) was a stronger predictor of stratification performance. When smaller active radiant ceiling areas are used (e.g., for a typical radiant ceiling panel layout), colder radiant surface temperatures are required to remove the same amount of cooling load (as a larger area), which cause more disruption to the room air stratification. Despite the impact that the chilled ceiling has on stratification, the results indicate that a minimum head–ankle temperature difference of 1.5°C (2.7°F) in the occupied zone (seated or standing) will be maintained for all radiant ceiling surface temperatures of 18°C (64.4°F) or higher.

[1]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[2]  Kamel Ghali,et al.  Simplified Thermal Model of Spaces Cooled with Combined Positive Displacement Ventilation and Chilled Ceiling System , 2006 .

[3]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[4]  Philip Haves,et al.  A nodal model for displacement ventilation and chilled ceiling systems in office spaces , 2001 .

[5]  Jorma Railio,et al.  Displacement Ventilation in Non-Industrial Premises , 2002 .

[6]  Peter V. Nielsen,et al.  Displacement Ventilation Guide in Non-Industrial Premises : EUROVENT, October 2003 , 2003 .

[7]  T. Kurabuchi,et al.  Cooled ceilings/displacement ventilation hybrid air conditioning system : Design criteria design criteria , 1998 .

[8]  Martin Behne,et al.  Indoor air quality in rooms with cooled ceilings.: Mixing ventilation or rather displacement ventilation? , 1999 .

[9]  Ergonomics of the thermal environment — Instruments for measuring physical quantities , 1998 .

[10]  Qingyan Chen,et al.  System Performance Evaluation and Design Guidelines for Displacement Ventilation , 1999 .

[11]  E. Iso,et al.  Measurement Uncertainty and Probability: Guide to the Expression of Uncertainty in Measurement , 1995 .

[12]  Francesco Causone,et al.  Floor heating and cooling combined with displacement ventilation: Possibilities and limitations , 2010 .

[13]  Hui Zhang,et al.  Modeling thermal comfort in stratified environments , 2005 .

[14]  Jelena Srebric,et al.  A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems , 2002 .

[15]  P. F. Grigg,et al.  Chilled ceilings and displacement ventilation , 1998 .