Influence of fault type on the optimal location of superconducting fault current limiter in electrical power grid

Abstract This paper presents a novel approach to determine the optimal location of a resistive superconducting fault current limiter (SFCL) to improve the transient stability of an electric power grid (EPG). The presented method use the angular separation of the rotors of synchronous machines present in the power system to select the optimal location of SFCL. The selection of this optimal location is coordinated with the corresponding optimal resistive value to improve transient stability in case of short-circuit fault. To obtain a global study on the optimal placement of SFCL in case of fault, various types of short-circuits are considered (single phase grounded fault, two phases grounded fault, etc.). To evaluate the effectiveness of the proposed method, the IEEE benchmarked four-machine two-area test system is used to carry out several case studies. It is shown that the optimal location of SFCL as well as its optimal resistance value are not the same for each fault studied. A global analysis of EPG stability is presented in the paper to select only one location of the SFCL in the EPG. Results show that the optimal location of SFCL combined with its optimal resistive value reduces the angular separation of the rotors that improves effectively the stability of the EPG for any type of short-circuit.

[1]  Jacob Coetzee,et al.  Analysis of electromagnetic forces in high voltage superconducting fault current limiters with saturated core , 2012 .

[2]  Dong Keun Park,et al.  Study on Optimal Location of a Resistive SFCL Applied to an Electric Power Grid , 2009, IEEE Transactions on Applied Superconductivity.

[3]  Y. Mitani,et al.  Application of resistor based superconducting fault current limiter to enhancement of power system transient stability , 2001 .

[4]  G. Burt,et al.  Analysis of Energy Dissipation in Resistive Superconducting Fault-Current Limiters for Optimal Power System Performance , 2011, IEEE Transactions on Applied Superconductivity.

[5]  Liangzhen Lin,et al.  Application studies of superconducting fault current limiters in electric power systems , 2002 .

[6]  Yuejin Tang,et al.  Influence of a voltage compensation type active superconducting fault current limiter on the transient stability of power system , 2009 .

[7]  P. Kundur,et al.  Power system stability and control , 1994 .

[8]  Jae-Chul Kim,et al.  Study on Application Method of Superconducting Fault Current Limiter for Protection Coordination of Protective Devices in a Power Distribution System , 2012, IEEE Transactions on Applied Superconductivity.

[9]  Gevork B. Gharehpetian,et al.  A dual-functional bridge type FCL to restore PCC voltage , 2013 .

[10]  Sung-Hun Lim,et al.  Analysis on Protection Coordination of Hybrid SFCL With Protective Devices in a Power Distribution System , 2011, IEEE Transactions on Applied Superconductivity.

[11]  Jung-Wook Park,et al.  A Study on the Direct Stability Analysis of Multi-Machine Power System With Resistive SFCL , 2012, IEEE Transactions on Applied Superconductivity.

[12]  L. Ye,et al.  Behavior Investigations of Superconducting Fault Current Limiters in Power Systems , 2006, IEEE Transactions on Applied Superconductivity.

[13]  Abdullah Swissi Emhemed,et al.  Analysis of Transient Stability Enhancement of LV-Connected Induction Microgenerators by Using Resistive-Type Fault Current Limiters , 2010, IEEE Transactions on Power Systems.

[14]  Antonio Morandi,et al.  State of the art of superconducting fault current limiters and their application to the electric power system , 2013 .

[15]  Dong Keun Park,et al.  Study on a Series Resistive SFCL to Improve Power System Transient Stability: Modeling, Simulation, and Experimental Verification , 2009, IEEE Transactions on Industrial Electronics.

[16]  P. Tixador,et al.  Tests and Simulations of Different YBCO Tapes for FCL , 2012, IEEE Transactions on Applied Superconductivity.

[17]  Jae-Chul Kim,et al.  Improvement of Recloser-Fuse Operations and Coordination in a Power Distribution System With SFCL , 2011, IEEE Transactions on Applied Superconductivity.

[18]  W. T. B. de Sousa,et al.  Simulations and Tests of MCP-BSCCO-2212 Superconducting Fault Current Limiters , 2012, IEEE Transactions on Applied Superconductivity.

[19]  Abderrezak Rezzoug,et al.  A novel approach to determine the optimal location of SFCL in electric power grid to improve power system stability , 2013, IEEE Transactions on Power Systems.

[20]  Mojtaba Khederzadeh,et al.  A novel approach to increase FCL application in preservation of over-current relays coordination in presence of asynchronous DGs , 2013 .

[21]  Z.Q. Zhu,et al.  Development and Test of 10.5 kV/1.5 kA HTS Fault Current Limiter , 2006, IEEE Transactions on Applied Superconductivity.

[22]  William D. Stevenson,et al.  Elements of Power System Analysis , 1962 .

[23]  Mehrdad Ghandhari,et al.  Improvement of power system stability by using a VSC-HVdc ☆ , 2011 .

[24]  R. Cherkaoui,et al.  Enhancement of power system transient stability using superconducting fault current limiters , 1999, IEEE Transactions on Applied Superconductivity.