LV chamber extraction from 3-D CT images--accuracy and precision.

Measurement of left ventricular (LV) chamber volume and shape from three-dimensional (3-D) CT images, generated by the fast X-ray CT scanner known as the dynamic spatial reconstructor, has previously been done using manual slice-image editing. To reduce the exorbitant operator analysis time and operator-dependent measurement variations of manual slice-image editing, we have devised a semiautomatic method for LV-chamber extraction. The method draws upon a minimum requirement for selective manual slice-image editing and mostly makes use of automatic image-analysis operations. Detailed validation results over a wide range of hemodynamic and image-analysis conditions show that the measurements of the semiautomatic method strongly correlate with those made via manual slice-image editing and exhibit a lower intertrial variability. Further, the method reduces operator interaction time by nearly an order of magnitude over that of manual slice-image editing, but provides more detailed 3-D structural definition.

[1]  Richard A. Robb,et al.  Imaging physiological functions: Experience with the dynamic spatial reconstructor , 1984 .

[2]  E L Ritman,et al.  Subtraction Gated Computed Tomography with the Dynamic Spatial Reconstructor: Simultaneous Evaluation of Left and Right Heart from Single Right‐Sided Bolus Contrast Medium Injection , 1984, Journal of computer assisted tomography.

[3]  Shigeki Yokoi,et al.  Basics of algorithms for processing three-dimensional digitized pictures , 1986, Systems and Computers in Japan.

[4]  Christian Barillot,et al.  Multidimensional ultrasonic imaging for cardiology , 1988, Proc. IEEE.

[5]  R A Robb,et al.  Interactive display and analysis of 3-D medical images. , 1989, IEEE transactions on medical imaging.

[6]  E. Hoffman,et al.  Shape and dimensions of cardiac chambers: importance of CT section thickness and orientation. , 1985, Radiology.

[7]  William E. Higgins,et al.  A flexible implementation of maximum-homogeneity filtering for 2-D and 3-D images , 1991, IEEE Trans. Signal Process..

[8]  R A Robb,et al.  Mass of left ventricular myocardium estimated with dynamic spatial reconstructor. , 1984, The American journal of physiology.

[9]  E L Ritman,et al.  Extraction of left-ventricular chamber from 3-D CT images of the heart. , 1990, IEEE transactions on medical imaging.

[10]  J. Udupa,et al.  Shape-based interpolation of multidimensional objects. , 1990, IEEE transactions on medical imaging.

[11]  S. Pizer Psychovisual issues in the display of medical images , 1986 .

[12]  E L Ritman,et al.  LV pressure-volume area and oxygen consumption: evaluation in intact dog by fast CT. , 1990, The American journal of physiology.

[13]  R A Karwoski,et al.  Estimation of tissue volume from serial tomographic sections. A statistical random marking method. , 1988, Investigative radiology.

[14]  Brian W. Kernighan,et al.  The UNIX™ programming environment , 1979, Softw. Pract. Exp..