Emission of microorganisms from biofilters

Experiments are reported on the discharge of microbial germs by biofilter systems used for the treatment of waste gases containing volatile organic compounds. The systems investigated concern six full-scale filter installations located in the Netherlands in several branches of industry, as well as a laboratory-scale installation used for modelling the discharge process. It is concluded that the number of microbial germs (mainly bacteria and to a much smaller extent moulds) in the outlet gas of the different full scale biofilters varies between 103 and 104 m−3, a number which is only slightly higher than the number encountered in open air and of the same order of magnitude encountered in indoor air. It is furthermore concluded that the concentration of microorganisms of a highly contaminated inlet gas is considerably reduced by the filtration process. On the basis of the experiments performed in the laboratory-scale filter bed, it is shown that the effect of the gas velocity on the discharge process results from two distinctive mechanisms: capture and emission. A theoretical model is presented describing the rate processes of both mechanisms. The model presented and the experimentally determined data agree rather well.

[1]  S. Friedlander Particle diffusion in low-speed flows. , 1967, Journal of colloid and interface science.

[2]  C. Clark,et al.  A comparison of two-stage and six-stage Andersen impactors for viable aerosols , 1981 .

[3]  J. C. Spendlove,et al.  Coliform Aerosols Emitted by Sewage Treatment Plants , 1970, Science.

[4]  R. Kniseley,et al.  Precision of the all-glass impinger and the andersen microbial impactor for air sampling in solid-waste handling facilities , 1981, Applied and environmental microbiology.

[5]  W. Jones,et al.  Evaluation of the Andersen viable impactor for single stage sampling. , 1985, American Industrial Hygiene Association journal.

[6]  M. Small,et al.  A study of bacterial aerosols at a wastewater irrigation site. , 1976, Journal - Water Pollution Control Federation.

[7]  D. Kingston Selective media in air sampling: a review. , 1971, The Journal of applied bacteriology.

[8]  N. Abuaf,et al.  Diffusional filtration of dust in a fluidized bed , 1976 .

[9]  R Rylander,et al.  Levels of gram-negative bacteria, Aspergillus fumigatus, dust, and endotoxin at compost plants , 1983, Applied and environmental microbiology.

[10]  A. Humphrey,et al.  Fibrous Filters for Air Sterilization - Design Procedure , 1956 .

[11]  Chaim Gutfinger,et al.  Theoretical and experimental investigation on granular bed dust filters , 1979 .

[12]  R. Roffey,et al.  Three-year investigation of the natural airborne bacterial flora at four localities in sweden , 1978, Applied and environmental microbiology.

[13]  R. Clift,et al.  REMOVAL OF FINE PARTICULATES FROM GASES IN FLUIDIZED-BEDS , 1978 .

[14]  K. R. May,et al.  The Efficiency of Various Liquid Impinger Samplers in Bacterial Aerosols , 1957, British journal of industrial medicine.

[15]  S. Ottengraf,et al.  Kinetics of organic compound removal from waste gases with a biological filter , 1983, Biotechnology and bioengineering.

[16]  A. M. Squires,et al.  Panel bed filters for simultaneous removal of fly ash and sulfur dioxide. 3. Reaction of sulfur dioxide with half-calcined dolomite. , 1971, Journal of the Air Pollution Control Association.

[17]  R. Kniseley,et al.  Airborne microorganisms in a municipal solid waste recovery system. , 1985, Canadian journal of microbiology.

[18]  L. F. Elliott,et al.  Bacteria in the Air of Housed Swine Units , 1976, Applied and environmental microbiology.