Titre : Title : Comparison of different cardiovascular magnetic resonance sequences for native myocardial T 1 mapping at 3 T Auteurs :

Background: T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different sequences head to head however are sparse. Methods: We compared three T1 mapping sequences, ShMOLLI, MOLLI and SASHA in phantoms and in a mid-ventricular slice of 40 healthy individuals (mean age 59 ± 7 years, 45 % male) with low (68 %) or moderate cardiovascular risk. We calculated global and segmental T1 in vivo through exponential curve fitting and subsequent parametric mapping. We also analyzed image quality and inter-observer reproducibility. Results: There was no association of T1 with cardiovascular risk groups. T1 however differed significantly depending on the sequence, with SASHA providing consistently higher mean values than ShMOLLI and MOLLI (1487 ± 36 ms vs. 1174 ± 37 ms and 1199 ± 28 ms, respectively; p < 0.001). This difference between sequences was much smaller in phantom measurements. In patients, segmental values were lower in the anterior wall for all sequences. Image quality, in general good for the steady-state-free-precession readouts in all sequences, was lower for SASHA parametric maps. On multivariate regression analysis, a longer T1 measured by MOLLI was correlated with lower ejection fraction and female gender. Inter-observer variability as assessed by intra-class correlation coefficients was excellent for all sequences (ShMOLLI: 0.995; MOLLI: 0.991; SASHA: 0.961; all p < 0.001). Conclusion: In a cross-sectional population with low to moderate cardiovascular risk, we observed a variation in T1 mapping results between inversion-recovery vs. saturation-recovery sequences in vivo, which were less evident in phantom images, despite a small interobserver variability. Thus, physiological factors, most likely related to B1 inhomogeneities, and tissue-specific properties, like magnetization transfer, that impact T1 values in vivo, render phantom validation insufficient, and have to be further investigated for a better understanding of the clinical utility of different T1 mapping approaches. Trial registration: “Canadian Alliance For Healthy Hearts and Minds” – ClinicalTrials.gov NCT02220582; registered August 18, 2014.

[1]  Reza Nezafat,et al.  A T1 and ECV phantom for global T1 mapping quality assurance: The T1 mapping and ECV standardisation in CMR (T1MES) program , 2016, Journal of Cardiovascular Magnetic Resonance.

[2]  N. Geller,et al.  Hypertrophic Cardiomyopathy Registry: The rationale and design of an international, observational study of hypertrophic cardiomyopathy. , 2015, American heart journal.

[3]  Christine L. Tardif,et al.  On the accuracy of T1 mapping: Searching for common ground , 2015, Magnetic resonance in medicine.

[4]  Marcelo Sánchez,et al.  T1 mapping: characterisation of myocardial interstitial space , 2014, Insights into Imaging.

[5]  David M Higgins,et al.  Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study , 2014, Journal of Cardiovascular Magnetic Resonance.

[6]  Peter Kellman,et al.  Optimized saturation recovery protocols for T1-mapping in the heart: influence of sampling strategies on precision , 2014, Journal of Cardiovascular Magnetic Resonance.

[7]  Richard B Thompson,et al.  Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping , 2014, Magnetic resonance in medicine.

[8]  Richard B. Thompson,et al.  Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE. , 2014, Radiology.

[9]  Mehmet Akçakaya,et al.  Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability , 2014, Magnetic resonance in medicine.

[10]  Richard B. Thompson,et al.  Improved precision in SASHA T1 mapping with a variable flip angle readout , 2014, Journal of Cardiovascular Magnetic Resonance.

[11]  P. Kellman,et al.  T1-mapping in the heart: accuracy and precision , 2014, Journal of Cardiovascular Magnetic Resonance.

[12]  M. Robson,et al.  Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement , 2013, Journal of Cardiovascular Magnetic Resonance.

[13]  Stefan Neubauer,et al.  T1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences , 2013, Magnetic resonance in medicine.

[14]  Peter Kellman,et al.  Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method , 2013, Journal of Cardiovascular Magnetic Resonance.

[15]  Thoralf Niendorf,et al.  Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications , 2013, Journal of Cardiovascular Magnetic Resonance.

[16]  S. K. White,et al.  Identification and Assessment of Anderson-Fabry Disease by Cardiovascular Magnetic Resonance Noncontrast Myocardial T1 Mapping , 2013, Circulation. Cardiovascular imaging.

[17]  Scott D Flamm,et al.  Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing , 2013, Journal of Cardiovascular Magnetic Resonance.

[18]  M. Friedrich,et al.  Canadian Society for Cardiovascular Magnetic Resonance (CanSCMR) recommendations for cardiovascular magnetic resonance image analysis and reporting. , 2013, The Canadian journal of cardiology.

[19]  Andrew S Flett,et al.  Human non-contrast T1 values and correlation with histology in diffuse fibrosis , 2013, Heart.

[20]  S. K. White,et al.  Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5 T using ShMOLLI , 2013, Journal of Cardiovascular Magnetic Resonance.

[21]  M. Robson,et al.  Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance , 2012, Journal of Cardiovascular Magnetic Resonance.

[22]  D. Bluemke,et al.  Myocardial T1 mapping with MRI: Comparison of look‐locker and MOLLI sequences , 2011, Journal of magnetic resonance imaging : JMRI.

[23]  Stefan Neubauer,et al.  Dynamic Changes of Edema and Late Gadolinium Enhancement After Acute Myocardial Infarction and Their Relationship to Functional Recovery and Salvage Index , 2011, Circulation. Cardiovascular imaging.

[24]  Stefan Neubauer,et al.  Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold , 2010, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[25]  Dwight G Nishimura,et al.  A robust methodology for in vivo T1 mapping , 2010, Magnetic resonance in medicine.

[26]  O. Simonetti,et al.  T2 quantification for improved detection of myocardial edema , 2009, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[27]  David M Higgins,et al.  Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart , 2004, Magnetic resonance in medicine.

[28]  J. Schulz-Menger,et al.  T1 mapping in patients with acute myocardial infarction. , 2003, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[29]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.