Immunohistochemistry of deparaffinised sections using antigen retrieval with microwave combined pressure cooking versus immunofluorescence in the assessment of human renal biopsies

Background Immunofluorescence of frozen tissue sections (IF-F) is a traditional technique used in renal biopsy. However, IF-F has certain disadvantages, such as a few or even no glomeruli in the section, and limited long-term preservation of the fluorescently labelled samples. Methods We compared two-step immunohistochemistry (IHC) staining of deparaffinised sections for antigen retrieval with microwave combined high-pressure cooking to IF-F used to detect antigens of IgG, IgA, IgM, C3, C1q, κ and λ in patient renal biopsy samples. The number of glomeruli detected, sensitivity and specificity of positive staining, tissue structure, and location staining of the antigens were determined using the two methods in 285 patients diagnosed with different renal diseases. Results Concordant observations between IF-F and IHC were 99% for all antigen staining (1969 of 1995 observations) and 100% for IgG, IgA and IgM (all 285 observations). The number of glomeruli in IHC sections was significantly greater compared with IF-F sections (p<0.001). IHC provided clearer images of tissue structure, more precise localisation of positive-staining antigens, and IHC staining allowed simultaneous evaluation of tissue by light microscopy. Correlation between tissue structure and immune deposits are not readily attained by IF-F. Conclusions IHC is superior to IF-F for immunopathological diagnosis of renal biopsy tissue and is a reliable replacement for the more traditional IF-F method.

[1]  F. Murad,et al.  Immunolocalization of nitric oxide synthase isoforms in human archival and rat tissues, and cultured cells , 2011, Journal of Neuroscience Methods.

[2]  A. Agaimy,et al.  Sclerosing nodular lesions of the gastrointestinal tract containing large numbers of IgG4 plasma cells , 2011, Pathology.

[3]  A. Rhodes,et al.  The reliability of rabbit monoclonal antibodies in the immunohistochemical assessment of estrogen receptors, progesterone receptors, and HER2 in human breast carcinomas. , 2010, American journal of clinical pathology.

[4]  A. Leong,et al.  Citraconic anhydride: a new antigen retrieval solution , 2010, Pathology.

[5]  F. Espíndola,et al.  Comparative analysis of two immunohistochemical methods for antigen retrieval in the optical lobe of the honeybee Apis mellifera: myosin-V assay. , 2010, Biological Research.

[6]  M. A. Sanders,et al.  Advanced laboratory techniques for sample processing and immunolabeling using microwave radiation , 2009, Journal of Neuroscience Methods.

[7]  S. Temel,et al.  Immunohistochemical detection of p53 protein in basal cell skin cancer after microwave-assisted antigen retrieval , 2009, Journal of Molecular Histology.

[8]  Ya-jing Han,et al.  Microwave Antigen Retrieval Blocks Endogenous Peroxidase Activity in Immunohistochemistry , 2008, Applied immunohistochemistry & molecular morphology : AIMM.

[9]  A. Liesegang,et al.  Vitamin D receptor amounts across different segments of the gastrointestinal tract in Brown Swiss and Holstein Frisean cows of different age. , 2008, Journal of animal physiology and animal nutrition.

[10]  G. Saed Immunohistochemical staining of cyclooxygenases with monoclonal antibodies. , 2008, Methods in molecular biology.

[11]  J. Piffkó,et al.  Significance of wet autoclave pretreatment in immunohistochemistry , 2008, Pathology and Oncology Research.

[12]  V. D’Agati,et al.  Immunofluorescence on pronase-digested paraffin sections: a valuable salvage technique for renal biopsies. , 2006, Kidney international.

[13]  M. Breimer,et al.  Immunoperoxidase versus immunofluorescence in the assessment of human renal biopsies. , 2005, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[14]  J. Petrali,et al.  Immunolocalization of MAP-2 in Routinely Formalin-Fixed, Paraffin-Embedded Guinea Pig Brain Sections Using Microwave Irradiation: A Comparison of Different Combinations of Antibody Clones and Antigen Retrieval Buffer Solutions , 2005, Microscopy and Microanalysis.

[15]  K. Tsuneyama,et al.  Improved 1-h rapid immunostaining method using intermittent microwave irradiation: practicability based on 5 years application in Toyama Medical and Pharmaceutical University Hospital , 2004, Modern Pathology.

[16]  Joseph A. DiGiuseppe,et al.  Immunohistochemical Detection of Immunoglobulin Light Chain Expression in B-Cell Non-Hodgkin Lymphomas Using Formalin-Fixed, Paraffin-Embedded Tissues and a Heat-Induced Epitope Retrieval Technique , 2002, Applied immunohistochemistry & molecular morphology : AIMM.

[17]  J. H. Dierendonck,et al.  Comparison of the effects of microwave heating and high pressure cooking for antigen retrieval of human and rat Bcl-2 protein in formaldehyde-fixed, paraffin-embedded sections , 2002, Biotechnic & histochemistry : official publication of the Biological Stain Commission.

[18]  J. Gu,et al.  Antigen Retrieval Techniques: Immunohistochemistry and Molecular Morphology , 2000 .

[19]  C. Thomas,et al.  Immunoperoxidase for the demonstration of immune deposits in renal biopsies , 2000 .

[20]  R. Cote,et al.  Antigen Retrieval Immunohistochemistry: Past, Present, and Future , 1997, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[21]  P. Furness,et al.  Electron microscopy and immunocytochemistry in the assessment of renal biopsy specimens: actual and optimal practice. , 1996, Journal of clinical pathology.

[22]  K. Gatter,et al.  p53 Overexpression in laryngeal squamous cell carcinoma and dysplasia , 1995, Clinical molecular pathology.

[23]  P. Hogendoorn,et al.  Immunostaining of chain-specific keratins on formalin-fixed, paraffin-embedded tissues: a comparison of various antigen retrieval systems using microwave heating and proteolytic pre-treatments. , 1995, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[24]  E. Matutes Contribution of immunophenotype in the diagnosis and classification of haemopoietic malignancies. , 1995, Journal of clinical pathology.

[25]  R. Atkins,et al.  A novel, simple, reliable, and sensitive method for multiple immunoenzyme staining: use of microwave oven heating to block antibody crossreactivity and retrieve antigens. , 1995, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[26]  K. Schmid,et al.  Possible role of tissue‐bound calcium ions in citrate‐mediated high‐temperature antigen retrieval , 1994, The Journal of pathology.

[27]  M. Key,et al.  Antigen retrieval in formalin-fixed, paraffin-embedded tissues: an enhancement method for immunohistochemical staining based on microwave oven heating of tissue sections. , 1991, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[28]  A. Leong,et al.  Accelerated immunohistochemical staining by microwaves , 1990, The Journal of pathology.

[29]  R. Thompson,et al.  Technical improvements in the immunoperoxidase study of renal biopsy specimens. , 1990, Journal of clinical pathology.

[30]  M. Mihatsch,et al.  Comparison of immunofluorescent findings in kidney after snap-freezing and formalin fixation. , 1989, Pathology, research and practice.

[31]  K. Lai,et al.  PATTERN OF GLOMERULONEPHRITIS IN HONG KONG , 1988, Pathology (Sydney).

[32]  K. Chan,et al.  Rapid immunofluorescence staining of human renal biopsy specimens using microwave irradiation. , 1987, Journal of clinical pathology.

[33]  Sheila Moriber Katz,et al.  Renal Disease: Classification and Atlas of Glomerular Diseases , 1982 .

[34]  J. Burns,et al.  Immunoperoxidase staining of formalin-fixed, paraffin-embedded, human renal biopsies with a comparison of the peroxidase-antiperoxidase (PAP) and indirect methods. , 1981, Journal of clinical pathology.

[35]  B. Mepham,et al.  Demonstration of extracellular immunoproteins in formalin-fixed renal biopsy specimens. , 1979, Kidney international.