Respiratory Protection Against Mycobacterium tuberculosis: Quantitative Fit Test Outcomes for Five Type N95 Filtering-Facepiece Respirators

In preparing to fit test a large workforce, a respirator program manager needs to initially choose respirators that will fit the greatest proportion of employees and achieve the best fits. This article discusses our strategy in selecting respirators from an initial array of seven NIOSH-certified Type N95 filtering-facepiece devices for a respiratory protection program against Mycobacterium tuberculosis (M. tb) aerosol. The seven respirators were screened based on manufacturer-provided fit test data, comfort, and cost. From these 7 devices, 5 were chosen for quantitative fit testing on 40 subjects who were a convenience sample from a cohort of approximately 30,000 workers scheduled to undergo fit testing. Across the five brands, medium/regular-size respirators fit from 8% to 95% of the subjects; providing another size of the same brand improved the pass rates slightly. Gender was not found to significantly affect fit test pass rates for any respirator brand. Among test panel members, an Aearo Corporation respirator (TC 84A-2630) and a 3M Company respirator (TC 84A-0006) provided the highest overall pass rates of 98% and 90%, respectively. We selected these two brands for fit testing in the larger worker cohort. To date, these two respirators have provided overall pass rates of 98% (1793/1830) and 88% (50/57), respectively, which are similar to the test panel results. Among 1850 individuals who have been fit tested, 1843 (99.6%) have been successfully fitted with one or the other brand. In a separate analysis, we used the test panel pass rates to estimate the reduction in M. tb infection risk afforded by the medium/regular-size of five filtering-facepiece respirators. We posed a low-exposure versus a high-exposure scenario for health care workers and assumed that respirators could be assigned without conducting fit testing, as proposed by many hospital infection control practitioners. Among those who would pass versus fail the fit test, we assumed an average respirator penetration (primarily due to faceseal leakage) of .04 and 0.3, respectively. The respirator with the highest overall pass rate (95%) reduced M. tb infection risk by 95%, while the respirator with the lowest pass rate (8%) reduced M. tb infection risk by only 70%. To promote the marketing of respirators that will successfully fit the highest proportion of wearers, and to increase protection for workers who might use respirators without the benefit of being fit tested, we recommend that fit testing be part of the NIOSH certification process for negative-pressure air-purifying respirators with tightly fitting facepieces. At a minimum, we recommend that respirator manufacturers generate and provide pass rate data to assist in selecting candidate respirators. In any event, program managers can initially select candidate respirators by comparing quantitative fit tests for a representative sample of their employee population.

[1]  M. Nicas Refining a risk model for occupational tuberculosis transmission. , 1996, American Industrial Hygiene Association journal.

[2]  R C Spear,et al.  A probability model for assessing exposure among respirator wearers: Part II-Overexposure to chronic versus acute toxicants. , 1992, American Industrial Hygiene Association journal.

[3]  J T McConville,et al.  Respirator protection factors: Part I -- Development of an anthropometric test panel. , 1978, American Industrial Hygiene Association journal.

[4]  R C Spear,et al.  A probability model for assessing exposure among respirator wearers: Part I--Description of the model. , 1992, American Industrial Hygiene Association journal.

[5]  C C Coffey,et al.  Performance of N95 respirators: filtration efficiency for airborne microbial and inert particles. , 1998, American Industrial Hygiene Association journal.

[6]  R. Riley,et al.  Infectiousness of air from a tuberculosis ward. Ultraviolet irradiation of infected air: comparative infectiousness of different patients. , 1962, The American review of respiratory disease.

[7]  David Satcher,et al.  Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care facilities, 1994--CDC. Notice of final revisions to the "Guidelines for Preventing the Transmission of Mycobacterium Tuberculosis in health-care facilities, 1994". , 1994, Federal register.

[8]  Z Zhuang,et al.  Field performance measurements of half-facepiece respirators--foundry operations. , 1996, American Industrial Hygiene Association journal.

[9]  R. Weber,et al.  Measuring performance of a half-mask respirator in a styrene environment. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[10]  M. Key National Institute for Occupational Safety and Health; occupational exposure to inorganic lead: request for comments and information; republication--NIOSH. Request for comments and information relevant to occupational exposure to inorganic lead. , 1997, Federal register.

[11]  A. Catanzaro Nosocomial tuberculosis. , 1982, The American review of respiratory disease.

[12]  J. Konz,et al.  Exposure factors handbook , 1989 .

[13]  M. Nicas Respiratory protection and the risk of Mycobacterium tuberculosis infection. , 1995, American journal of industrial medicine.

[14]  D L Campbell,et al.  Simulated workplace performance of N95 respirators. , 1999, American Industrial Hygiene Association journal.

[15]  M. Field Tuberculosis in the Workplace , 2001 .