Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants

All air-conditioning systems experience transient processes during start-up and shutdown and varying boundary conditions during operation due to changes in space loads and outdoor air loads, control loop operation, etc. Transient characteristics of split air conditioners that use R-22 and R-410A as refrigerants are presented in this paper. The model used for the overall system simulation comprises compressor, capillary, condenser, and evaporator submodels. The condenser and evaporator are modelled using continuity, momentum, and energy equations over the space and time span, using the implicit finite difference approach. Both of the heat exchangers are assumed to be made up of microfin tubes, although a comparison of transient pressure response with smooth tubes is presented in the paper. Appropriate correlations are used for calculating the two-phase heat transfer coefficients, the liquid vapor slip, and the friction factors. A simulation program is developed in the MATLAB (Mathworks 2004) environment linked with REFPROP for refrigerant properties. The program is validated with measured and published experimental data. The transient simulation results including the pressure, the temperature, and the mass flow rate response for a start-up transient are compared for R-22 and its alternative R-410A. The transient loss during start-up due to the reconditioning of thermal mass of the system and redistribution of the refrigerant among the system components is also compared for the two refrigerants.

[1]  S. Devotta,et al.  Alternatives to HCFC-22 for air conditioners , 2001 .

[2]  V. W. Goldschmidt,et al.  Cyclic characteristics of a typical residential air conditioner-modeling of start-up transients , 1985 .

[3]  Eric W. Grald,et al.  A moving-boundary formulation for modeling time-dependent two-phase flows , 1992 .

[4]  S. Lin,et al.  Local frictional pressure drop during vaporization of R-12 through capillary tubes , 1991 .

[5]  P. G. Jolly,et al.  Distributed study of air temperature inside a dry-expansion evaporator , 1996 .

[6]  D. Didion,et al.  A simulation model of the transient performance of a heat pump , 1982 .

[7]  N. Tanaka,et al.  Experimental study on the dynamic characteristics of a heat pump , 1982 .

[8]  M. Goto,et al.  Condensation and evaporation heat transfer of R410A inside internally grooved horizontal tubes , 2001 .

[9]  Ricardo Nicolau Nassar Koury,et al.  Numerical simulation of a variable speed refrigeration system , 2001 .

[10]  Gisbert Stoyan,et al.  A dynamical model adequate for controlling the evaporator of a heat pump , 1994 .

[11]  Samuel M. Sami,et al.  Numerical prediction of dynamic performance of vapour-compression heat pump using new HFC alternatives to HCFC-22 , 1996 .

[12]  Guoliang Ding,et al.  Recent developments in simulation techniques for vapour-compression refrigeration systems , 2007 .

[13]  J. M. Calm,et al.  R-22 Replacement Status , 2004 .

[14]  S. Koyama,et al.  An investigation on void fraction of vapor–liquid two-phase flow for smooth and microfin tubes with R134a at adiabatic condition , 2004 .

[15]  S. M. Sami,et al.  Experimental study of the dynamic behaviour of non-azeotropic binary mixtures in heat pumps , 1991 .

[16]  J. MacArthur,et al.  Theoretical analysis of the dynamic interactions of vapor compression heat pumps , 1984 .

[17]  Guoliang Ding,et al.  Dynamic simulation of air-to-water dual-mode heat pump with screw compressor , 2003 .

[18]  Somchai Wongwises,et al.  Flow characteristics of pure refrigerants and refrigerant mixtures in adiabatic capillary tubes , 2001 .

[19]  Clark W. Bullard,et al.  Dynamic Characteristics of a R-410A Split Air Conditioning System , 2001 .

[20]  A. Cavallini,et al.  Heat transfer and pressure drop during condensation of refrigerants inside horizontal enhanced tubes , 2000 .

[21]  David A. Yashar,et al.  An Investigation of Refrigerant Void Fraction in Horizontal, Microfin Tubes , 2001 .

[22]  Jun Wang,et al.  Start-up and shut-down operation in a reciprocating compressor refrigeration system with capillary tubes , 1990 .

[23]  David Didion,et al.  Refrigerant Migration in a Split-Unit Air Conditioner | NIST , 1985 .

[24]  J. MacArthur,et al.  Unsteady compressible two-phase flow model for predicting cyclic heat pump performance and a comparison with experimental data , 1989 .

[25]  Pradeep Bansal,et al.  Transient simulation of vapour-compression packaged liquid chillers , 2002 .

[26]  P. Haberschill,et al.  Dynamic Model of a Vapor-Compression Refrigerating Machine Using R-407C , 2003 .

[27]  L. Kuijpers,et al.  Cycling losses in domestic appliances: an experimental and theoretical analysis , 1992 .

[28]  R. Yun,et al.  A generalized correlation for evaporation heat transfer of refrigerants in micro-fin tubes , 2002 .

[29]  P. G. Jolly,et al.  Distributed steady and dynamic modelling of dry-expansion evaporators , 1999 .

[30]  Morten Willatzen,et al.  A general dynamic simulation model for evaporators and condensers in refrigeration. Part I: moving-boundary formulation of two-phase flows with heat exchange , 1998 .

[31]  S. Devotta,et al.  Steady- and dynamic-state simulations of heat-pumps. Part III: Comparison between predictions and measurements , 1989 .

[32]  C. C. Wang,et al.  Single-phase heat transfer and flow friction correlations for microfin tubes , 1996 .

[33]  N. Galanis,et al.  Prediction of the transient response of heat pumps , 1987 .

[34]  Savvas A. Tassou,et al.  Dynamic characteristics of an air-to-water heat-pump system , 1992 .

[35]  Amr El-Sayed Alaa El-Din Gado DEVELOPMENT OF A DYNAMIC TEST FACILITY FOR ENVIRONMENTAL CONTROL SYSTEMS , 2006 .

[36]  S. Lin,et al.  Correlations for heat transfer and pressure drop factors for direct expansion air cooling and dehumidifying coils , 1988 .

[37]  Morten Willatzen,et al.  A general dynamic simulation model for evaporators and condensers in refrigeration. Part II: simulation and control of an evaporator , 1998 .

[38]  Reinhard Radermacher,et al.  A heat exchanger model for mixtures and pure refrigerant cycle simulations , 1997 .

[39]  P. G. Jolly,et al.  A distributed model for prediction of the transient response of an evaporator , 1995 .

[40]  Samuel M. Sami,et al.  Numerical prediction of capillary tube behaviour with pure and binary alternative refrigerants , 1998 .

[41]  S. Touber,et al.  Distributed and non-steady-state modelling of an air cooler , 1991 .

[42]  E. Filho,et al.  Convective boiling pressure drop of refrigerant R-134a in horizontal smooth and microfin tubes , 2004 .

[43]  Pradeep Bansal,et al.  An homogeneous model for adiabatic capillary tubes , 1998 .

[44]  J. MacArthur Transient heat pump behaviour: a theoretical investigation , 1984 .