Single-Phase Phase-Locked Loop Based on Derivative Elements

High-performance phase-locked loops (PLLs) are critical for power control in grid-connected systems. This paper presents a new method of designing a PLL for single-phase systems based on derivative elements (DEs). The quadrature signal generator (QSG) is constructed by two DEs with the same parameters. The PLL itself is realized by using the DE-based QSG. It avoids errors due to the overlap and accumulation that are present in PLLs based on integral elements, such as a PLL based on a second-order generalized integrator. Additionally, frequency feedback is not needed which allows the proposed PLL to achieve high performance when the grid frequency changes rapidly. This paper presents the model of the PLL and a theoretical performance analysis with respect to both the frequency-domain and time-domain behavior. The error arising from the discretization process is also compensated, ensuring this PLL method is suitable for implementation in a digital control system. Simulation and experimental results show that the proposed PLL achieves good performance in both harmonic rejection and dynamic response.

[1]  Josep M. Guerrero,et al.  Comparative Performance Evaluation of Orthogonal-Signal-Generators-Based Single-Phase PLL Algorithms—A Survey , 2016, IEEE Transactions on Power Electronics.

[2]  Hui Li,et al.  DC Offset Error Compensation for Synchronous Reference Frame PLL in Single-Phase Grid-Connected Converters , 2012, IEEE Transactions on Power Electronics.

[3]  Roland E. Best Phase-locked loops : design, simulation, and applications , 2003 .

[4]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[5]  Frede Blaabjerg,et al.  The influence of phase-locked loop on the stability of single-phase grid-connected inverter , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[6]  Josep M. Guerrero,et al.  Design and Tuning of a Modified Power-Based PLL for Single-Phase Grid-Connected Power Conditioning Systems , 2012, IEEE Transactions on Power Electronics.

[7]  Yu Zhang,et al.  Instantaneous Current-Sharing Control Strategy for Parallel Operation of UPS Modules Using Virtual Impedance , 2013, IEEE Transactions on Power Electronics.

[8]  G. Joos,et al.  A Nonlinear Adaptive Synchronization Techniquefor Grid-Connected Distributed Energy Sources , 2008, IEEE Transactions on Power Electronics.

[9]  Krzysztof Galkowski,et al.  Control Systems Theory and Applications for Linear Repetitive Processes - Recent Progress and Open Research Questions , 2007 .

[10]  Irfan Yazici,et al.  Fast and robust software-based digital phase-locked loop for power electronics applications , 2013 .

[11]  Alireza R. Bakhshai,et al.  Estimation of Power System Frequency Using Adaptive Notch Filter , 2005, 2005 IEEE Instrumentationand Measurement Technology Conference Proceedings.

[12]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[13]  D.G. Holmes,et al.  Improved power converter line synchronisation using an adaptive Discrete Fourier Transform (DFT) , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[14]  Leland B. Jackson,et al.  Approximating Noncausal IIR Digital Filters Having Arbitrary Poles, Including New Hilbert Transformer Designs, Via Forward/Backward Block Recursion , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[15]  Yun Wei Li,et al.  Grid synchronization PLL based on cascaded delayed signal cancellation , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[16]  Yang Zheng,et al.  Control of a six-switch inverter based single-phase grid-connected PV generation system with inverse Park transform PLL , 2012, 2012 IEEE International Symposium on Industrial Electronics.

[17]  Josep M. Guerrero,et al.  Dynamics Assessment of Advanced Single-Phase PLL Structures , 2013, IEEE Transactions on Industrial Electronics.

[18]  M. L. Kolhe,et al.  Integration of DC power source in micro-grid using VSI with PLL technique , 2015, 2015 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE).

[19]  Naresh K. Sinha,et al.  Modern Control Systems , 1981, IEEE Transactions on Systems, Man, and Cybernetics.

[20]  C Picardi,et al.  A simple and low-cost PLL structure for single-phase grid-connected inverters , 2010, SPEEDAM 2010.

[21]  Josep M. Guerrero,et al.  dq-Frame Cascaded Delayed Signal Cancellation- Based PLL: Analysis, Design, and Comparison With Moving Average Filter-Based PLL , 2015, IEEE Transactions on Power Electronics.

[22]  Zhengyu Lu,et al.  A high performance PLL for polluted utility grid based on cascade adaptive notch filters , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[23]  Dushan Boroyevich,et al.  Phase-Locked Loop Noise Reduction via Phase Detector Implementation for Single-Phase Systems , 2011, IEEE Transactions on Industrial Electronics.

[24]  Roberto Langella,et al.  On the Effects of Unbalances, Harmonics and Interharmonics on PLL Systems , 2013, IEEE Transactions on Instrumentation and Measurement.

[25]  Gabriel Garcerá,et al.  An Adaptive Synchronous-Reference-Frame Phase-Locked Loop for Power Quality Improvement in a Polluted Utility Grid , 2012, IEEE Transactions on Industrial Electronics.

[26]  F. Blaabjerg,et al.  Grid synchronization of power converters using multiple second order generalized integrators , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[27]  A. Nagliero,et al.  Comparison and evaluation of the PLL techniques for the design of the grid-connected inverter systems , 2010, 2010 IEEE International Symposium on Industrial Electronics.

[28]  Pablo Fernandez-Comesana,et al.  A Signal-Processing Adaptive Algorithm for Selective Current Harmonic Cancellation in Active Power Filters , 2009, IEEE Transactions on Industrial Electronics.

[29]  S.M. Silva,et al.  Performance evaluation of PLL algorithms for single-phase grid-connected systems , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[30]  N. Matsui,et al.  A control strategy of single-phase active filter using a novel d-q transformation , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[31]  M. Karimi-Ghartemani,et al.  A Unifying Approach to Single-Phase Synchronous Reference Frame PLLs , 2013, IEEE Transactions on Power Electronics.

[32]  M. A. Arjona,et al.  Development of a Grid-Connected Wind Generation System With a Modified PLL Structure , 2012, IEEE Transactions on Sustainable Energy.

[33]  Jee-Hoon Jung,et al.  High-Efficiency Isolated Bidirectional AC–DC Converter for a DC Distribution System , 2013, IEEE Transactions on Power Electronics.

[34]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[35]  Boon-Teck Ooi,et al.  Application of Enhanced Phase-Locked Loop System to the Computation of Synchrophasors , 2011, IEEE Transactions on Power Delivery.

[36]  Heung-Geun Kim,et al.  PLL-Based Seamless Transfer Control Between Grid-Connected and Islanding Modes in Grid-Connected Inverters , 2014, IEEE Transactions on Power Electronics.

[37]  Frede Blaabjerg,et al.  Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems , 2013, IEEE Transactions on Industry Applications.

[38]  Alireza R. Bakhshai,et al.  Time-Domain Signal Analysis Using Adaptive Notch Filter , 2007, IEEE Transactions on Signal Processing.

[39]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.