Automated planar patch-clamp.

Ion channels are integral membrane proteins that regulate the flow of ions across the plasma membrane and the membranes of intracellular organelles of both excitable and non-excitable cells. Ion channels are vital to a wide variety of biological processes and are prominent components of the nervous system and cardiovascular system, as well as controlling many metabolic functions. Furthermore, ion channels are known to be involved in many disease states and as such have become popular therapeutic targets. For many years now manual patch-clamping has been regarded as one of the best approaches for assaying ion channel function, through direct measurement of ion flow across these membrane proteins. Over the last decade there have been many remarkable breakthroughs in the development of technologies enabling the study of ion channels. One of these breakthroughs is the development of automated planar patch-clamp technology. Automated platforms have demonstrated the ability to generate high-quality data with high throughput capabilities, at great efficiency and reliability. Additional features such as simultaneous intracellular and extracellular perfusion of the cell membrane, current clamp operation, fast compound application, an increasing rate of parallelization, and more recently temperature control have been introduced. Furthermore, in addition to the well-established studies of over-expressed ion channel proteins in cell lines, new generations of planar patch-clamp systems have enabled successful studies of native and primary mammalian cells. This technology is becoming increasingly popular and extensively used both within areas of drug discovery as well as academic research. Many platforms have been developed including NPC-16 Patchliner(®) and SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich), CytoPatch™ (Cytocentrics AG, Rostock), PatchXpress(®) 7000A, IonWorks(®) Quattro and IonWorks Barracuda™, (Molecular Devices, LLC); Dynaflow(®) HT (Cellectricon AB, Mölndal), QPatch HT (Sophion A/S, Copenhagen), IonFlux HT (Fluxion Bioscience Inc, USA), which have demonstrated the capability to generate recordings similar in quality to that of conventional patch clamping. Here we describe features of Nanion's NPC-16 Patchliner(®) and processes and protocols suited for this particularly flexible and successful high-throughput automated platform, which is based on planar patch-clamp technology. However, many of the protocols and notes given in this chapter can be applied to other automated patch-clamp platforms, similarly.

[1]  Liudmila Polonchuk,et al.  Toward a New Gold Standard for Early Safety: Automated Temperature-Controlled hERG Test on the PatchLiner® , 2012, Front. Pharmacol..

[2]  C. January,et al.  Properties of HERG channels stably expressed in HEK 293 cells studied at physiological temperature. , 1998, Biophysical journal.

[3]  P. Emery,et al.  TRPC channel activation by extracellular thioredoxin , 2008, Nature.

[4]  Clemens Möller,et al.  Automated Electrophysiology Makes the Pace for Cardiac Ion Channel Safety Screening , 2011, Front. Pharmacol..

[5]  Ofer Binah,et al.  Functional and developmental properties of human embryonic stem cells-derived cardiomyocytes. , 2007, Journal of electrocardiology.

[6]  B. Sakmann,et al.  Single-channel currents recorded from membrane of denervated frog muscle fibres , 1976, Nature.

[7]  D. Bertrand,et al.  A Novel Positive Allosteric Modulator of the α7 Neuronal Nicotinic Acetylcholine Receptor: In Vitro and In Vivo Characterization , 2005, The Journal of Neuroscience.

[8]  Gary R. Mirams,et al.  Application of human stem cell-derived cardiomyocytes in safety pharmacology requires caution beyond hERG. , 2012, Journal of molecular and cellular cardiology.

[9]  David J Beech,et al.  Pregnenolone Sulphate- and Cholesterol-Regulated TRPM3 Channels Coupled to Vascular Smooth Muscle Secretion and Contraction , 2010, Circulation research.

[10]  Eduardo Ríos,et al.  Ion-dependent Inactivation of Barium Current through L-type Calcium Channels , 1997, The Journal of general physiology.

[11]  O. Krishtal,et al.  Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cells , 1975, Nature.

[12]  Jon T. Brown,et al.  Voltage- and Temperature-Dependent Allosteric Modulation of α7 Nicotinic Receptors by PNU120596 , 2011, Front. Pharmacol..

[13]  Victoria A. L. Seymour,et al.  Rapid and Contrasting Effects of Rosiglitazone on Transient Receptor Potential TRPM3 and TRPC5 Channels , 2011, Molecular Pharmacology.

[14]  D. Nutt,et al.  Psychotropic Drugs, Cardiac Arrhythmia, and Sudden Death , 2003, Journal of clinical psychopharmacology.

[15]  Jing Li,et al.  Interactions, Functions, and Independence of Plasma Membrane STIM1 and TRPC1 in Vascular Smooth Muscle Cells , 2008, Circulation research.

[16]  Marius Wernig,et al.  Comparison of contractile behavior of native murine ventricular tissue and cardiomyocytes derived from embryonic or induced pluripotent stem cells , 2010, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[17]  Marcus J. Drake,et al.  The Validation of a Functional, Isolated Pig Bladder Model for Physiological Experimentation , 2012, Front. Pharmacol..

[18]  Ralf Kettenhofen,et al.  Automated Patch Clamp on mESC-Derived Cardiomyocytes for Cardiotoxicity Prediction , 2011, Journal of biomolecular screening.

[19]  S. Fedulova,et al.  Effects of substituting barium for calcium ions during research into inward currents in mammalian neurons , 2005, Neurophysiology.

[20]  Michael George,et al.  Planar patch clamp: advances in electrophysiology. , 2008, Methods in molecular biology.

[21]  Mark L Dallas,et al.  Robotic multiwell planar patch-clamp for native and primary mammalian cells , 2009, Nature Protocols.

[22]  Mohamed Chahine,et al.  New Insights into Cardiac and Brain Sodium Channels Modulation by Beta Blockers , 2011, Front. Pharmacol..

[23]  Ralf Kettenhofen,et al.  State-of-the-Art Automated Patch Clamp Devices: Heat Activation, Action Potentials, and High Throughput in Ion Channel Screening , 2011, Front. Pharmacol..

[24]  J. Ruskin,et al.  Drug‐Induced Torsades de Pointes and Implications for Drug Development , 2004, Journal of cardiovascular electrophysiology.

[25]  Michael George,et al.  Automated ion channel screening: patch clamping made easy , 2007, Expert opinion on therapeutic targets.