Ultrasensitive detection of bacteria using core-shell nanoparticles and an NMR-filter system.

Direct detection of pathogens is key in combating human infections, in identifying nosocomial sources, in surveying food chains and in biodefense.[1] Recent advances in nanotechnology have enabled the development of new diagnostic platforms[2] aimed at more sensitive and faster pathogen detection.[3] Many of the reported technologies, albeit elegant, often fail in routine clinical settings[4] because they still require extensive specimen purification, use complex measurement setups, or are not easily scalable for clinical demands. Here we report a new, simple, nanoparticle-based platform that can rapidly detect pathogens in native biological samples. In this approach, bacteria are targeted by highly magnetic nanoparticles (MNP), concentrated into a microfluidic chamber, and detected by nuclear magnetic resonance (NMR). The clinical utility of our diagnostic platform was evaluated by detecting tuberculosis (TB), a leading cause of disease and death worldwide.[5] Using the bacillus Calmette-Guerin (BCG) as a surrogate for Mycobacterium tuberculosis, we demonstrate unprecedented detection speed and sensitivity; as few as 20 colony-forming unit (CFU) in sputum (1 mL) were detected in < 30 min. With the capability for fast, simple and portable operation, the new detection platform could be an ideal point-of-care diagnostic tool, especially in resource-limited settings. The diagnosis starts with specimen collection and incubation with bacteria specific MNP (Supporting Information Figure S1). MNP bind to the bacterial wall, rendering the bacteria superparamagnetic. In a subsequent step the spin-spin relaxation time (T2) of the whole sample is measured by NMR. As the magnetic fields from MNP dephase the precession of nuclear spins in water protons[6, 7], each MNP-tagged bacterium can shorten the T2 of billions of surrounding water molecules. To increase detection sensitivity, we have incorporated signal amplification schemes that made it possible to detect small quantities of bacteria in relatively large sample volumes. At the nanoparticle level, the detection signal has been enhanced by synthesizing Fe-based MNP with the high transverse relaxivity (r2). At the device level, the signal was amplified by concentrating bacteria into a microfluidic chamber where the NMR signal was measured. To provide portable, on-chip bacterial detection, the NMR signal was read out using a miniaturized NMR system we have recently developed.[8]. First, we developed hybrid MNP with a large Fe core and a thin ferrite shell (“cannonballs”; CB), that have very high r2 per particle (Table S1). With the limited number of binding sites per bacterium, the T2 of samples will be shorter and thereby the detection will be more sensitive when the individual MNP have higher r2. Since r2 is ∝ M2•d2, where M and d are the particle magnetization and the diameter respectively[6], we focused on making larger MNP using highly magnetic material (Fe). Figure 1a shows an example of highly mono-disperse CB (d = 16 nm). Initially, we made Fe-only MNP by thermally decomposing Fe(CO)5, followed by controlled air-oxidation to grow the ferrite shell.[9] Compared to chemical oxidation[10], our method produces a thinner shell and thereby leaves a larger Fe core (Figure S2), leading to higher M. The shell showed high crystallinity (Figure 1b) and X-ray diffraction revealed a typical pattern for a spinel structure (Figure 1c), confirming the ferrite nature of the shell.[11] The shell protected the Fe core from oxidation to maintain the magnetic properties of CB (Figure S3). CB showed high magnetization (139 emu g−1 [Fe]) and yet were superparamagnetic at room temperature (Figure 1d). Most importantly, CB assumed high r2 (= 6.1×10−11 m L s−1, 1.5 T; Figure S4), due to their high magnetization and large diameter. Figure 1 Cannonballs (CB) for bacterial targeting. a) The particles have a large metallic core (Fe) passivated with a thin ferrite shell, resulting in high particle relaxivity (> 5×10−11 mL s−1 at 0.5 T). The core diameter and the ... To render CB specific for BCG, we conjugated anti-BCG monoclonal antibodies to their surface (CB-BCG; see Methods in Supporting Information). Bacterial samples were then incubated with CB-BCG for 10 min, followed by a wash step to remove excess particles. Optical microscopy with fluorescent CB-BCG showed excellent targeting (Figure 2a). Binding of CB-BCG was further verified by the element mapping (Figure 2b), which showed high Fe signal on the bacterial membrane. The number of CB-BCG per bacterium, quantified by inductively coupled plasma atomic emission spectroscopy (ICP-AES; Figure S5), was ≈ 105. Magnetic tagging thus made the bacteria highly efficient T2-shortening agents (Figure 2c). The binding of CB-BCG to BCG could be inhibited by antibody blockade against bacterial epitopes. For control CB or when CB-BCG were used against other bacterial strains, the CB binding was minimal with T2 changes (ΔT2) < 5%. The number of CB-BCG tested against different bacteria species were < 600 per bacterium (Figure S5), confirming the specificity of CB-BCG. Figure 2 Selective BCG targeting with CB-BCG. a) Confocal micrograph of BCG incubated with fluorescently labeled CB-BCG. b) Transmission electron micrograph of BCG targeted with CB-BCG. Element mapping detected high Fe signal on a whole bacterium. c) Specificity ... To further enhance detection sensitivity and to streamline assay procedures, we next developed a chip-based filter system with NMR compatibility (Figure 3). A key component is a microfluidic chamber enclosed by a membrane filter and surrounded by a microcoil. The membrane filter performs two functions. First, it captures bacteria and concentrates them into the microfluidic chamber for NMR detection, providing a way to detect a small number of bacteria from large sample volumes. Second, the filter enables on-chip separation of bacteria from unbound CB, obviating the need for separate off-chip purification steps. Figure 4a illustrates the operating principle of the NMR-filter system. An unpurified sample is introduced into the microfluidic channel. Bacteria are retained by the membrane (pore size ≈ 100 nm), while excess CB permeate. Subsequently, a buffer solution is repeatedly injected to wash off unbound CB and the membrane is backwashed to redisperse the captured bacteria. Figure 4b shows an operation example with a sample containing BCG and CB-BCG. After sample loading, the microfluidic channel was flushed with PBS to remove unbound CB-BCG. Finally, the flow direction was reversed to resuspend the captured BCG for NMR measurements. The number of washing steps to remove unbound CB-BCG was determined by measuring T2 after each wash (Figure 4c). T2 values plateaued in 4–5 washing steps with the whole washing procedure complete in 103 times higher detection sensitivity. Figure 3 NMR-filter system for bacterial concentration and detection. a) The system consists of a microcoil and a membrane filter integrated with a microfluidic channel. The microcoil is used for NMR measurements; the membrane filter concentrates bacteria inside ... Figure 4 Bacterial separation and concentration. a) The unprocessed sample containing bacteria and CB-BCG is introduced into the device. The membrane filter retains bacteria while unbound CB-BCG pass through. To remove free CB-BCG, the microfluidic channel is ... To compare the effect of MNP relaxivity on detection sensitivity, we first used a NMR system without a membrane filter. Two types of nanoparticles, CB and cross-linked iron oxide[12] (CLIO; r2 = 7.0×10−13 mL s−1), were used (Figure 5, black and blue curves). CB-BCG showed much higher mass sensitivity, detecting as few as 6 CFU (in 1 µL sample volume), whereas the detection limit was ~100 CFU with CLIO-BCG. Using the NMR-filter system, we achieved substantially high concentration detection sensitivity (Figure 5, red curve). When BCG samples (100 µL) targeted with CB-BCG were filtered, the concentration detection limit was ~60 CFU mL−1. It is important to note that the concentration limit is theoretically unlimited with the filtering, because bacteria can be concentrated into the NMR detection chamber from large sample volumes. Figure 5 Comparison of detection sensitivity. Measurements were performed on samples with varying BCG counts to determine detection sensitivities. First, a microfluidic chip without a membrane filter was used to determine the intrinsic mass-detection limits. BCG ... To evaluate the clinical utility of the NMR-filter system, we performed comparative detection assays (Table S3). Pulmonary samples were prepared by spiking BCG into human sputa. Following liquefaction, samples were subjected to standard TB diagnostic tests, culture and acid-fast bacilli (AFB) smear microscopy, and CB-based NMR measurements. Without filtration, NMR measurements had a similar sensitivity to AFB smear microscopy, with a detection threshold of ~103 CFU/mL. However, the NMR method was less prone to human error and less labor-intensive. With the NMR-filter system, the detection sensitivity was comparable to that of culture-based detection; when 1-mL of samples were filtered, the detection limit was ~20 CFU. The NMR-based detection was much faster ( 2 weeks) and facility-dependent (e.g. incubators). These results demonstrate that the CB-based NMR-filter system can be readily applied for TB diagnosis in clinical settings.[13]

[1]  Martin Enserink,et al.  Biodefense Hampered by Inadequate Tests , 2001, Science.

[2]  C. Batt Food Pathogen Detection , 2007, Science.

[3]  Vincent M Rotello,et al.  Rapid and efficient identification of bacteria using gold-nanoparticle-poly(para-phenyleneethynylene) constructs. , 2008, Angewandte Chemie.

[4]  M. D. Alper,et al.  Detection of bacteria in suspension by using a superconducting quantum interference device , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[5]  S. S. Olmsted,et al.  Requirements for high impact diagnostics in the developing world , 2006, Nature.

[6]  A Paul Alivisatos,et al.  Vacancy coalescence during oxidation of iron nanoparticles. , 2007, Journal of the American Chemical Society.

[7]  M. Struelens,et al.  Microbiology of nosocomial infections: progress and challenges. , 2004, Microbes and infection.

[8]  R Weissleder,et al.  High-efficiency intracellular magnetic labeling with novel superparamagnetic-Tat peptide conjugates. , 1999, Bioconjugate chemistry.

[9]  P. Luo,et al.  Nanotechnology in the detection and control of microorganisms. , 2008, Advances in applied microbiology.

[10]  R. Brooks,et al.  T2‐shortening by strongly magnetized spheres: A chemical exchange model † , 2002, Magnetic resonance in medicine.

[11]  Uwe H. F. Bunz,et al.  Effiziente Erkennung von Bakterien mit Goldnanopartikel‐Poly(para‐phenylenethinylen)‐Konstrukten , 2008 .

[12]  Ralph Weissleder,et al.  Magnetic relaxation switches capable of sensing molecular interactions , 2002, Nature Biotechnology.

[13]  Federico Girosi,et al.  Reducing the global burden of tuberculosis: the contribution of improved diagnostics , 2006, Nature.

[14]  Jin Xie,et al.  Synthesis and stabilization of monodisperse Fe nanoparticles. , 2006, Journal of the American Chemical Society.

[15]  Lisa R. Hilliard,et al.  A rapid bioassay for single bacterial cell quantitation using bioconjugated nanoparticles. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[16]  Chad A Mirkin,et al.  Nanostructures in biodiagnostics. , 2005, Chemical reviews.

[17]  Donhee Ham,et al.  Chip–NMR biosensor for detection and molecular analysis of cells , 2008, Nature Medicine.

[18]  P. Bruce,et al.  Synthesis of ordered mesoporous Fe3O4 and gamma-Fe2O3 with crystalline walls using post-template reduction/oxidation. , 2006, Journal of the American Chemical Society.