Bursting pressures of CO2 laser‐welded rabbit lleum

In this study, the short‐term bond strength of laser‐welded New Zealand white rabbit ileum was examined. Forty‐eight longitudinally oriented 0.5‐cm transmural, scalpel incisions were reanastomosed solely through the use of the CO2 continuous wave laser at low energy levels. Random power levels of 250, 500, 750, or 1,000 mW were delivered to weld sites by either continuous application for 30 seconds or a pulsating application (ie, 0.5 seconds on, 0.5 seconds off) for 60 seconds. This provided 53.6, 107.1, 160.7, and 214.3 J/cm2, respectively. With the aid of a plexiglass clamp and pressure monitored infusion system, each type of weld was tested six times to determine the intraluminal hydrostatic pressure required to burst the welded seam 1 minute after completing the weld. For the welds made with 107.1, 160.7, and 214.3 J/cm2 in both lasing modes, the mean bursting pressure was 40.7 mmHg (SD ± 24.9) with no statistically significant difference in weld strengths at these energy densities. There was also no difference between continuous and pulsating delivery methods. However, the energy density of 53.6 J/cm2 in either method produced a mean bursting pressure significantly lower than those produced by the higher energy densities tested and below the estimated basal ileal intraluminal pressure of approximately 9 mmHg. Since 107.1 J/cm2 energy density caused the minimal gross tissue changes while producing an equally strong bond and since continuous is faster than pulsating, 500 mW of continuous delivery was considered the optimal setting for the CO2 laser welding of rabbit ileum.

[1]  K. K. Jain,et al.  SUTURELESS EXTRA-INTRACRANIAL ANASTOMOSIS BY LASER , 1984, The Lancet.

[2]  C. Lynne,et al.  Laser‐Assisted Vas Anastomosis: A Preliminary Report , 1983, Lasers in surgery and medicine.

[3]  K. Jain,et al.  Sutureless microvascular anastomosis using a neodymium‐yag laser , 1980, Journal of microsurgery.

[4]  S. Fink,et al.  The intraluminal pressures in the intact human intestine. , 1959, Gastroenterology.

[5]  M. Dawood,et al.  Conventional Versus Laser Reanastomosis of Rabbit Ligated Uterine Horns , 1983, Obstetrics and Gynecology.

[6]  J. Uitto,et al.  Control of connective tissue metabolism by lasers: recent developments and future prospects. , 1984, Journal of the American Academy of Dermatology.

[7]  H. K. Hartline,et al.  INTUBATION STUDIES OF THE HUMAN SMALL INTESTINE. XXI. A METHOD FOR MEASURING INTRA-LUMINAL PRESSURES AND ITS APPLICATION TO THE DIGESTIVE TRACT. , 1943, The Journal of clinical investigation.

[8]  K. Jain Sutureless End-to-Side Microvascular Anastomosis Using Neodymium-YAG Laser , 1983 .

[9]  R Grosspietzsch,et al.  Animal in vivo studies and in vitro experiments with human tubes for end-to-end anastomotic operation by a CO2-laser technique. , 1978, Fertility and sterility.

[10]  J K Choe,et al.  Clinical and histologic evaluation of laser reanastomosis of the uterine tube. , 1984, Fertility and sterility.

[11]  L. Wise,et al.  Telescoping anastomosis of the colon: A comparative study , 1979, Diseases of the colon and rectum.

[12]  P. Ascher,et al.  Handbook of laser neurosurgery , 1983 .

[13]  W Gorisch,et al.  Repair of small blood vessels with the neodymium-YAG laser: a preliminary report. , 1979, Surgery.