Practical Considerations in the Use of Real-Time Continuous Glucose Monitoring Alerts

Background: The safety and efficacy of real-time (RT) continuous glucose monitoring (CGM) systems in the management of type 1 diabetes are increasingly apparent. Clinical trials have demonstrated the utility of these systems in lowering hemoglobin A1c, minimizing hypoglycemia, and reducing glycemic variability. These RT systems allow patients to conveniently monitor their glucose levels by displaying concentration and trending information. Several of these RT systems provide preset alerts that sound when absolute glucose thresholds are reached. Additionally, some systems allow for predictive algorithm-based alerts that incorporate rates of change. However, clinical trials have identified significant noncompliance in the use of these devices, most notably in the pediatric and adolescent populations. A retrospective review of CGM reports shows that many patients set high and low alert thresholds at levels that result in frequent alerts, potentially resulting in patient nuisance, dismissal of consequential alerts, and eventual product abandonment. Therefore, setting the alert thresholds at appropriate high and low settings can determine the balance between either a perceived benefit by the patient and their long-term use of CGM systems or annoyance to the patient and discontinuation. Conclusion: Care should be taken to set CGM alerts at levels that result in a manageable number of notifications per day. In some cases, providers should consider not using alerts at all or consider using broad targets when initiating CGM to maximize alert specificity. Real-time CGM is safe and generally well tolerated; however, individualization of alert settings is necessary maximize the system's benefits and patient adherence.

[1]  Howard C. Zisser,et al.  Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study. , 2007, Diabetes technology & therapeutics.

[2]  R. Beck Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment , 2009, Diabetes Care.

[3]  Howard Wolpert,et al.  Clinical application of emerging sensor technologies in diabetes management: consensus guidelines for continuous glucose monitoring (CGM). , 2008, Diabetes technology & therapeutics.

[4]  Anthony Firek,et al.  Combined Insulin Pump Therapy with Real-Time Continuous Glucose Monitoring Significantly Improves Glycemic Control Compared to Multiple Daily Injection Therapy in Pump Naïve Patients with Type 1 Diabetes; Single Center Pilot Study Experience , 2007, Journal of diabetes science and technology.

[5]  Christopher G. Parkin,et al.  Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. , 2008, Diabetes technology & therapeutics.

[6]  W. Tamborlane,et al.  Sensor-augmented pump therapy in type 1 diabetes , 2008, Current opinion in endocrinology, diabetes, and obesity.

[7]  Eric Renard,et al.  Incremental valúe of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the REALTREND Study , 2010 .

[8]  Howard Zisser,et al.  Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. , 2006, Diabetes care.

[9]  D. B. Keenan,et al.  Accuracy of a New Real-Time Continuous Glucose Monitoring Algorithm , 2010, Journal of diabetes science and technology.

[10]  Howard Wolpert,et al.  Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 Diabetes , 2009, Diabetes Care.

[11]  Howard Wolpert,et al.  Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. The effect of continuous glucose monitoring in well-controlled type 1 diabetes , 2009 .

[12]  F. Ovalle,et al.  Continuous Glucose Monitoring and Intensive Treatment of Type 1 Diabetes , 2009 .

[13]  John J. Mastrototaro,et al.  Early clinical experience with an integrated continuous glucose sensor/insulin pump platform , 2006 .

[14]  Darrell M. Wilson,et al.  The effect of continuous glucose monitoring in well-controlled type 1 diabetes , 2010 .

[15]  Irl B. Hirsch,et al.  Clinical review: Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist. , 2009, The Journal of clinical endocrinology and metabolism.

[16]  L. Jovanovic,et al.  Relationship of Fasting and Hourly Blood Glucose Levels to HbA1c Values , 2006, Diabetes Care.

[17]  E. Ryan,et al.  Use of continuous glucose monitoring system in the management of severe hypoglycemia. , 2009, Diabetes technology & therapeutics.

[18]  J. Mastrototaro,et al.  Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. , 2004, Diabetes technology & therapeutics.

[19]  J. Mastrototaro,et al.  The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. , 2008, Diabetes technology & therapeutics.