Integrated microfluidic chip for endothelial cells culture and analysis exposed to a pulsatile and oscillatory shear stress.

For a comprehensive understanding of cells or tissues, it is important to enable multiple studies under the controllable microenvironment of a chip. In this report, we present an integrated microfluidic cell culture platform in which endothelial cells (ECs) are under static conditions or exposed to a pulsatile and oscillatory shear stress. Through the integration of a microgap, self-contained flow loop, pneumatic pumps, and valves, the novel microfluidic chip achieved multiple functions: pulsatile and oscillatory fluid circulation, cell trapping, cell culture, the formation of ECs barrier, and adding shear stress on cells. After being introduced into the chip by gravity, the ECs arranged along the microgap with the help of hydrodynamic forces and grew in the microchannel for more than 7 days. The cells proliferated and migrated to form a barrier at the microgap to mimic the vessel wall, which separated the microenvironment into two compartments, microchannel and microchamber. An optimized pneumatic micropump was embedded to actuate flow circulation in a self-contained loop that induced a pulsatile and oscillatory shear stress at physiological levels on the ECs in the microchannel. All the analyses were performed under either static or dynamic conditions. The performance of the barrier was evaluated by the diffusion and distribution behaviors of fluorescently labeled albumin. The permeability of the barrier was comparable to that in traditional in vitro assays. The concentration gradients of the tracer formed in the microchamber can potentially be used to study cell polarization, migration and communications in the future. Additionally, the morphology and cytoskeleton of the ECs response to the pulsatile and oscillatory shear stress were analyzed. The microfluidic chip provided a multifunctional platform to enable comprehensive studies of blood vessels at the cell or tissue level.

[1]  C. Nathan,et al.  Nitric oxide as a secretory product of mammalian cells , 1992, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[2]  D. Ku,et al.  Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress , 1985, Arteriosclerosis.

[3]  R M Nerem,et al.  Effects of pulsatile flow on cultured vascular endothelial cell morphology. , 1991, Journal of biomechanical engineering.

[4]  K. Jensen,et al.  Cells on chips , 2006, Nature.

[5]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[6]  G. Whitesides,et al.  Generation of Solution and Surface Gradients Using Microfluidic Systems , 2000 .

[7]  D. Rifkin,et al.  Inhibition of endothelial cell movement by pericytes and smooth muscle cells: activation of a latent transforming growth factor-beta 1-like molecule by plasmin during co-culture , 1989, The Journal of cell biology.

[8]  Yuqing Wan,et al.  Cell adhesion on gaseous plasma modified poly-(L-lactide) surface under shear stress field. , 2003, Biomaterials.

[9]  M. Manimaran,et al.  Multi-step microfluidic device for studying cancer metastasis. , 2007, Lab on a chip.

[10]  B. L. Langille,et al.  Shear Stress Regulates Forward and Reverse Planar Cell Polarity of Vascular Endothelium In Vivo and In Vitro , 2006, Circulation research.

[11]  M. Poo,et al.  Endothelial cell polarization and chemotaxis in a microfluidic device. , 2008, Lab on a chip.

[12]  Hsian-Rong Tseng,et al.  An integrated microfluidic culture device for quantitative analysis of human embryonic stem cells. , 2009, Lab on a chip.

[13]  Mengsu Yang,et al.  Cell docking and on-chip monitoring of cellular reactions with a controlled concentration gradient on a microfluidic device. , 2002, Analytical chemistry.

[14]  H. Kimura,et al.  An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models. , 2008, Lab on a chip.

[15]  William Shain,et al.  An endothelial and astrocyte co-culture model of the blood-brain barrier utilizing an ultra-thin, nanofabricated silicon nitride membrane. , 2005, Lab on a chip.

[16]  S. Quake,et al.  Versatile, fully automated, microfluidic cell culture system. , 2007, Analytical chemistry.

[17]  Shuichi Takayama,et al.  Computer-controlled microcirculatory support system for endothelial cell culture and shearing. , 2005, Analytical chemistry.

[18]  Sadao Kimura,et al.  A novel potent vasoconstrictor peptide produced by vascular endothelial cells , 1988, Nature.

[19]  C F Dewey,et al.  Turbulent fluid shear stress induces vascular endothelial cell turnover in vitro. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[20]  R. Paul,et al.  Eicosonoid metabolism and beta-adrenergic mechanisms in coronary arterial smooth muscle: potential compartmentation of cAMP. , 1986, The American journal of physiology.

[21]  Matsuhiko Nishizawa,et al.  Controlled cocultures of HeLa cells and human umbilical vein endothelial cells on detachable substrates. , 2009, Lab on a chip.

[22]  C. W. Frank,et al.  The Effect of Atrial and Ventricular Tachycardia on Cardiac Output, Coronary Blood Flow and Mean Arterial Blood Pressure , 1958, Circulation research.

[23]  A. Fishman,et al.  Permeability characteristics of cultured endothelial cell monolayers. , 1988, Journal of applied physiology.

[24]  Gwo-Bin Lee,et al.  Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels , 2006 .

[25]  J. Alexander,et al.  Vascular Permeability Factor/Vascular Endothelial Cell Growth Factor-mediated Permeability Occurs through Disorganization of Endothelial Junctional Proteins* , 1998, The Journal of Biological Chemistry.

[26]  William Thies,et al.  Digital microfluidics using soft lithography. , 2006, Lab on a chip.

[27]  C. Loudon,et al.  The use of the dimensionless Womersley number to characterize the unsteady nature of internal flow. , 1998, Journal of theoretical biology.

[28]  Luke P. Lee,et al.  An artificial liver sinusoid with a microfluidic endothelial-like barrier for primary hepatocyte culture. , 2007, Biotechnology and bioengineering.

[29]  R M Nerem,et al.  Oscillatory shear stress stimulates adhesion molecule expression in cultured human endothelium. , 1998, Circulation research.

[30]  A. Khademhosseini,et al.  Microscale technologies for tissue engineering and biology. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[31]  Frank-Ulrich Gast,et al.  The development of integrated microfluidic systems at GeSiM. , 2003, Lab on a chip.

[32]  Shan-hui Hsu,et al.  Microvessel scaffold with circular microchannels by photoresist melting , 2007, Biomedical microdevices.

[33]  E. Jaffe,et al.  Culture of human endothelial cells derived from umbilical veins. Identification by morphologic and immunologic criteria. , 1973, The Journal of clinical investigation.

[34]  Gwo-Bin Lee,et al.  A high throughput perfusion-based microbioreactor platform integrated with pneumatic micropumps for three-dimensional cell culture , 2008, Biomedical microdevices.

[35]  A. Mantovani,et al.  Cytokine regulation of endothelial cell function: from molecular level to the bedside. , 1997, Immunology today.

[36]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[37]  S. Thorslund,et al.  A fluidic device to study directional angiogenesis in complex tissue and organ culture models. , 2009, Lab on a chip.

[38]  W. Risau,et al.  Mechanisms of angiogenesis , 1997, Nature.

[39]  H. Tseng,et al.  Integrated microfluidic devices for combinatorial cell-based assays , 2009, Biomedical microdevices.

[40]  Noo Li Jeon,et al.  Vascular mimetics based on microfluidics for imaging the leukocyte--endothelial inflammatory response. , 2007, Lab on a chip.

[41]  S Chien,et al.  Shear stress induces spatial reorganization of the endothelial cell cytoskeleton. , 1998, Cell motility and the cytoskeleton.