Modeling of Harmonic Sources Magnetic Core Saturation

Different transformer models have been developed in the past for steady state and transient analysis of power systems. Some of these models have nonlinear components to take into account the magnetic core saturation characteristics so that harmonic generation can be simulated. Case studies based on these models are presented to demonstrate the harmonic generation behaviors of transformers under different saturation conditions.

[1]  H. W. Dommel,et al.  On modelling iron core nonlinearities , 1993 .

[2]  Yahia Baghzouz,et al.  Voltage-dependent model for teaching transformer core nonlinearity , 1993 .

[3]  Drago Dolinar,et al.  Dynamic model of a three-phase power transformer , 1993 .

[4]  D. N. Ewart Digital Computer Simulation Model of a Steel-Core Transformer , 1986, IEEE Power Engineering Review.

[5]  A. Narang,et al.  Topology based magnetic model for steady-state and transient studies for three-phase core type transformers , 1994 .

[6]  V. Brandwajn,et al.  Matrix Representation of Three-Phase N-Winding Transformers for Steady-State and Transient Studies , 1982, IEEE Transactions on Power Apparatus and Systems.

[7]  W. M. Grady,et al.  An investigation of the harmonic characteristics of transformer excitation current under nonsinusoidal supply voltage , 1999 .

[8]  J. De La Ree,et al.  Harmonics generated from a DC biased transformer , 1992 .

[9]  L. Bolduc,et al.  Effects of direct currents in power transformers Part II. Simplified calculations for large transformers , 1978 .

[10]  S. S. Venkata,et al.  A three-phase three-winding core-type transformer model for low-frequency transient studies , 1997 .

[11]  Ewald F. Fuchs,et al.  Large signal nonlinear model of anisotropic transformers for nonsinusoidal operation. II. Magnetizing and core-loss currents , 1991 .

[12]  S. Lu,et al.  Harmonics form DC biased three-phase transformer banks , 1997 .

[13]  E.P. Dick,et al.  Transformer Models for Transient Studies Based on Field Measurements , 1981, IEEE Transactions on Power Apparatus and Systems.

[14]  Yan-Pei Wu,et al.  FFT algorithms for the harmonic analysis of three-phase transformer banks with magnetic saturation , 1991 .

[15]  B. R. Pelly,et al.  Thyristor Phase-Controlled Converters and Cycloconverters: Operation, Control, and Performance , 1971 .

[16]  Y. Mansour,et al.  Harmonics from SVC transformer saturation with direct current offset , 1994 .

[17]  C. A. Gross,et al.  Nonlinear modeling of transformers , 1988 .

[18]  Jos Arrillaga,et al.  Generalised modelling of power transformers in the harmonic domain , 1992 .

[19]  V. Albertson,et al.  Bracing for the geomagnetic storms , 1990, IEEE Spectrum.

[20]  R. M. Shier,et al.  Effects of geomagnetically induced currents in the BC Hydro 500 kV system , 1989 .

[21]  Shi Wei,et al.  Harmonics from Transformer Saturation , 1986, IEEE Transactions on Power Delivery.