Self-monitoring in carbon fiber reinforced mortar by reactance measurement
暂无分享,去创建一个
Wayne A. Anderson | D.D.L. Chung | Xiaoyun Fu | D. Chung | W. Anderson | Erming Ma | E. Ma | X. Fu
[1] P. Tumidajski. Electrical conductivity of Portland cement mortars , 1996 .
[2] Parviz Soroushian,et al. STRENGTHS OF RECYCLED AGGREGATE CONCRETE MADE USING FIELD-DEMOLISHED CONCRETE AS AGGREGATE , 1996 .
[3] D. Chung,et al. A COMPARATIVE STUDY OF CONCRETES REINFORCED WITH CARBON, POLYETHYLENE, AND STEEL FIBERS AND THEIR IMPROVEMENT BY LATEX ADDITION , 1996 .
[4] M. F. Kotkata,et al. Electrical conductivity of concrete containing silica fume , 1995 .
[5] D.D.L. Chung,et al. Carbon‐Fiber‐Reinforced Concrete as an Intrinsically Smart Concrete for Damage Assessment during Dynamic Loading , 1995 .
[6] N. Banthia,et al. Micro-fiber reinforced cement composites. I. Uniaxial tensile response , 1994 .
[7] J. Beaudoin,et al. APPLICATION OF A.C. IMPEDANCE TECHNIQUES IN STUDIES OF POROUS CEMENTITIOUS MATERIALS (II): RELATIONSHIP BETWEEN ACIS BEHAVIOR AND THE POROUS MICROSTRUCTURE , 1993 .
[8] H. Toutanji,et al. Behaviour of carbon fiber reinforced cement composites in direct tension , 1993 .
[9] J. Beaudoin,et al. Microstructural characterization of the transition zone in cement systems by means of A.C. impedance spectroscopy , 1993 .
[10] J. Beaudoin,et al. Application of A.C. impedance techniques in studies of porous cementitious materials , 1993 .
[11] D. Chung,et al. Carbon fiber reinforced concrete for smart structures capable of non-destructive flaw detection , 1993 .
[12] D.D.L. Chung,et al. Latex-modified cement mortar reinforced by short carbon fibres , 1992 .
[13] M. Pigeon,et al. Electrical resistivity of carbon and steel micro-fiber reinforced cements , 1992 .
[14] Burtrand I. Lee,et al. Experimental study on the engineering properties of carbon fiber reinforced cement composites , 1991 .
[15] D. Roy,et al. Influence of chemical composition and inorganic admixtures on the electrical conductivity of hydrating cement pastes , 1989 .
[16] P. Gu,et al. Contact capacitance effect in measurement of a.c. impedance spectra for hydrating cement systems , 1996 .
[17] D.D.L. Chung,et al. Self-monitoring of fatigue damage in carbon fiber reinforced cement , 1996 .
[18] Bill Batchelor,et al. An electrical conductivity method for measuring the effects of additives on effective diffusivities in Portland cement pastes , 1994 .
[19] A. Bentur,et al. Mechanical properties and pore structure of carbon fiber reinforced cementitious composites , 1994 .
[20] V. Li,et al. Effect of fiber length variation on tensile properties of carbon-fiber cement composites , 1994 .
[21] H. Nakagawa,et al. Fiber reinforced concrete: developments and applications to buildings , 1993 .
[22] Fadhel Aouadi,et al. LATEX-MODIFIED CARBON FIBER REINFORCED MORTAR , 1991 .