Monitoring of hydrogen sulfide via substrate-integrated hollow waveguide mid-infrared sensors in real-time.

Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e.g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10-100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e.g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e.g., breath analysis.

[1]  M. Insko,et al.  Detection of exhaled hydrogen sulphide gas in healthy human volunteers during intravenous administration of sodium sulphide. , 2010, British journal of clinical pharmacology.

[2]  Frank K. Tittel,et al.  H2S trace concentration measurements using off-axis integrated cavity output spectroscopy in the near-infrared , 2008 .

[3]  T. Guidotti Hydrogen Sulfide , 2010, International journal of toxicology.

[4]  Arvind K. Sharma,et al.  Concentration-time interactions in hydrogen sulphide toxicity in rats. , 1988, Canadian journal of veterinary research = Revue canadienne de recherche veterinaire.

[5]  Zoltán Bozóki,et al.  Photoacoustic system for on-line process monitoring of hydrogen sulfide (H2S) concentration in natural gas streams , 2006 .

[6]  Martin L. Spartz,et al.  Hydrogen Sulfide Detection by UV-Assisted Infrared Spectrometry , 1997 .

[7]  J. Springfield,et al.  Spontaneous Fluctuations in the Concentrations of Oral Sulfur-containing Gases , 2001, Journal of dental research.

[8]  B. Mizaikoff,et al.  Breath analysis with broadly tunable quantum cascade lasers. , 2013, Analytical chemistry.

[9]  Wei Xing,et al.  Electrochemical H2S sensor with H2SO4 pre-treated Nafion membrane as solid polymer electrolyte , 2002 .

[10]  M. Insko,et al.  Detection of exhaled hydrogen sulphide gas in rats exposed to intravenous sodium sulphide , 2009, British journal of pharmacology.

[11]  B. Mizaikoff,et al.  Near-Infrared Hollow Waveguide Gas Sensors , 2011, Applied Spectroscopy.

[12]  J A Harrington,et al.  Attenuation of incoherent infrared radiation in hollow sapphire and silica waveguides. , 1991, Optics letters.

[13]  W. Dong,et al.  Photolysis of low concentration H2S under UV/VUV irradiation emitted from microwave discharge electrodeless lamps. , 2008, Chemosphere.

[14]  Response surface modeling of H2S conversion by catalytic oxidation reaction over catalysts based on SiC nanoparticles using Box − Behnken experimental design , 2013 .

[15]  K. Toda,et al.  Field instrument for simultaneous large dynamic range measurement of atmospheric hydrogen sulfide, methanethiol, and sulfur dioxide. , 2004, Environmental Science and Technology.

[16]  Guojia Fang,et al.  Room temperature H2S sensing properties and mechanism of CeO2-SnO2 sol-gel thin films , 2000 .

[17]  Tadahiro Mori,et al.  Microbial Corrosion of Concrete Sewer Pipes, H2S Production from Sediments and Determination of Corrosion Rate , 1991 .

[18]  Timothy Day,et al.  External cavity widely tunable quantum cascade laser based hollow waveguide gas sensors for multianalyte detection , 2009 .

[19]  P. Radermacher,et al.  HEMODYNAMIC AND METABOLIC EFFECTS OF HYDROGEN SULFIDE DURING PORCINE ISCHEMIA/REPERFUSION INJURY , 2008, Shock.

[20]  R. A. Cox,et al.  Reactions of OH radicals with gaseous sulphur compounds , 1980, Nature.

[21]  Kea-Tiong Tang,et al.  A review of sensor-based methods for monitoring hydrogen sulfide , 2012 .

[22]  P. Dasgupta,et al.  Design and development of a system to measure ambient levels of hydrogen sulfide and lower mercaptans from a mobile platform , 1995 .

[23]  T. Berntsen,et al.  A global model of the coupled sulfur/oxidant chemistry in the troposphere: The sulfur cycle , 2004 .

[24]  Boris Mizaikoff,et al.  Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors , 2013, Scientific Reports.

[25]  Boris Mizaikoff,et al.  Infrared hollow waveguide sensors for simultaneous gas phase detection of benzene, toluene, and xylenes in field environments. , 2011, Analytical chemistry.

[26]  K. Sreenivas,et al.  Fast response H2S gas sensing characteristics with ultra-thin CuO islands on sputtered SnO2 , 2003 .

[27]  Robert G Hendrickson,et al.  Co-worker fatalities from hydrogen sulfide. , 2004, American journal of industrial medicine.

[28]  James A. Harrington,et al.  Small-Bore Hollow Waveguide Infrared Absorption Cells for Gas Sensing , 1996 .

[29]  N. Lawrence,et al.  Analytical strategies for the detection of sulfide: a review. , 2000, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[30]  Ki-Hyun Kim,et al.  A review of methods for the determination of reduced sulfur compounds (RSCs) in air. , 2009, Environmental science & technology.

[31]  Heqing Yan,et al.  Solid polymer electrolyte-based hydrogen sulfide sensor , 2002 .

[32]  Boris Mizaikoff,et al.  Substrate-integrated hollow waveguides: a new level of integration in mid-infrared gas sensing. , 2013, Analytical chemistry.

[33]  Wolfgang Schade,et al.  Fiber-optic evanescent-field laser sensor for in-situ gas diagnostics. , 2002, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[34]  R. Peverall,et al.  Laser spectroscopy on volatile sulfur compounds: possibilities for breath analysis , 2011, Journal of breath research.

[35]  A. Cardoso,et al.  A new palladium chelate compound for determination of sulfide , 2013 .

[36]  A. Cardoso,et al.  Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide. , 1997, Talanta.