The development of variably compliant haptic systems using magnetorheological fluids

In this study the authors develop haptic systems for telerobotic surgery. In order to model the full range of tactile force exhibited from an MR damper a microstructural, kinetic theory-based model of Magnetorheological (MR) fluids has been developed. Microscale constitutive equations relating flow, stress, and particle orientation are produced. The model developed is fully vectorial and relationships between the stress tensor and the applied magnetic field vector are fully exploited. The higher accuracy of the model in this regard gives better force representations of highly compliant objects. This model is then applied in force feedback control of single degree of freedom (SDOF) and two degrees of freedom (2DOF) systems. Carbonyl iron powders with different particle sizes mixed with silicone oils with different viscosities are used to make several sample MR fluids. These MR fluid samples are then used in three different designed MR dampers. A State feedback control algorithm is employed to control a SDOF system and tracking a 2-D profile path using a special innovative MR force feedback joystick. The results indicate that the MR based force feedback dampers can be used as effective haptic devices. The systems designed and constructed in this paper can be extended to a three degree of freedom force feedback system appropriate for telerobotic surgery.

[1]  S. Genç,et al.  SYNTHESIS AND PROPERTIES OF MAGNETORHEOLOGICAL (MR) FLUIDS , 2002 .

[2]  Gregory N. Washington,et al.  Microstructural Analysis and Control of Magneto-Rheological Fluid , 2004 .

[3]  Thomas H. Massie,et al.  The PHANToM Haptic Interface: A Device for Probing Virtual Objects , 1994 .

[4]  Xu Youlin,et al.  Seismic response control of a complex structure using multiple MR dampers: experimental investigation , 2004 .

[5]  Shirley J. Dyke,et al.  Phenomenological Model of a Magnetorheological Damper , 1996 .

[6]  E. C. Bingham Fluidity And Plasticity , 1922 .

[7]  J. Carlson,et al.  MR fluid, foam and elastomer devices , 2000 .

[8]  Gregory N. Washington,et al.  Design and Development of Passive and Active Force Feedback Systems Using Magnetorheological Fluids , 2003 .

[9]  Mark R. Jolly Pneumatic motion control using magnetorheological technology , 2001, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[10]  Grigore C. Burdea Haptic Feedback for Virtual Reality 1 , 1999 .

[11]  D S Krivitsky,et al.  Numerical solution of the Smoluchowski kinetic equation and asymptotics of the distribution function , 1995 .

[12]  Rui C. V. Loureiro,et al.  An Investigation on the Properties of Magneto Rheological Fluids for Assisting Upper Limb Movement Disorders on ADL , 2003 .

[13]  J. David Carlson,et al.  What Makes a Good MR Fluid? , 2002 .

[14]  J. David Carlson,et al.  Low-Cost MR Fluid Sponge Devices , 1999 .

[15]  Gregory N. Washington,et al.  Variable Transmission Compliance With an MR Damper , 2004 .

[16]  Gene F. Franklin,et al.  Feedback Control of Dynamic Systems , 1986 .

[17]  Jonathan W. Bender,et al.  Properties and Applications of Commercial Magnetorheological Fluids , 1998, Smart Structures.

[18]  Gregory N. Washington,et al.  Force feedback system using magneto-rheological fluids for telerobotic surgery , 2002, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[19]  Michael J. Chrzan,et al.  MR fluid sponge devices and their use in vibration control of washing machines , 2001, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[20]  Norman M. Wereley,et al.  ANALYSIS AND TESTING OF A LINEAR STROKE MAGNETORHEOLOGICAL DAMPER , 1998 .

[21]  Hiroo Iwata,et al.  Haptic interfaces , 2002 .

[22]  Peter Campbell Permanent Magnet Materials and their Application: Magnetic circuit design , 1994 .