Single-use duodenoscopes are an efficient tool for emergency ERCP in real life

Background  Biliary tract emergencies are managed with endoscopic retrograde cholangiopancreatography (ERCP) using duodenoscopes, which are reusable devices that require high-level disinfection to minimize risk of cross-contamination. Recent reports about newly developed single-use duodenoscopes (SUDs) suggest equivalent performance with reusable duodenoscopes, but the effectiveness of SUDs in emergency ERCP has not yet been studied. Patients and methods  We conducted a prospective case series of emergency ERCP procedures using SUDs (EXALT model D-Boston Scientific, United States) in a real-life, tertiary care setting without any possibility of using a back-up reusable duodenoscope. Results  Twenty-one emergent ERCPs (acute cholangitis 48%, severe jaundice 38 %, others 14 %) were performed in 19 patients (mean age 49.5±15 years). Almost all procedures (20 of 21; 95 %) were technically and clinically successful, whereas selective cannulation failed in one case. Among the successful ERCPs, five (24 %) were achieved by a novice operator. The image was often considered skewed toward yellow tones (48 %), whereas stiffness and pushability for stent insertion were found suboptimal in 5 % of the procedures, without any impact on procedure success. Conclusions  SUDs are effective and appropriate devices for emergent situations in real life even in non-expert hands and even if a regular duodenoscope is unavailable as a backup.

[1]  B. Petersen,et al.  Single-use duodenoscope for ERCP performed by endoscopists with a range of experience in procedures of variable complexity. , 2021, Gastrointestinal endoscopy.

[2]  M. Bulut,et al.  Sterile laparoscopic transgastric ERCP with single-use disposable duodenoscope , 2021, Endoscopy.

[3]  S. Varadarajulu,et al.  Single-use duodenoscopes: where are we and where are we going? , 2021, Current opinion in gastroenterology.

[4]  S. Lakhtakia,et al.  Single-use duodenoscope in the management of an elderly patient with difficult bile duct stones: laser lithotripsy using a disposable cholangioscope , 2021, VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy.

[5]  V. Muthusamy,et al.  Device profile of the EXALT Model D single-use duodenoscope for endoscopic retrograde cholangiopancreatography: overview of its safety and efficacy , 2021, Expert review of medical devices.

[6]  C. Boustière,et al.  Evaluation of the performances of a single‐use duodenoscope: Prospective multi‐center national study , 2021, Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society.

[7]  Rebecca Bromley-Dulfano,et al.  COVID-19 Solutions Are Climate Solutions: Lessons From Reusable Gowns , 2020, Frontiers in Public Health.

[8]  S. Varadarajulu,et al.  Equivalent performance of single-use and reusable duodenoscopes in a randomised trial , 2020, Gut.

[9]  B. Petersen,et al.  Novel single-use duodenoscope compared with 3 models of reusable duodenoscopes for ERCP: a randomized bench-model comparison. , 2020, Gastrointestinal endoscopy.

[10]  B. Petersen,et al.  Clinical evaluation of a single-use duodenoscope for endoscopic retrograde cholangiopancreatography. , 2019, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.

[11]  M. Bruno,et al.  Endoscope-associated infections: A brief summary of the current state and views toward the future , 2019, Techniques in Gastrointestinal Endoscopy.

[12]  M. Bruno,et al.  High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study , 2018, Gut.

[13]  R. Bellomo,et al.  The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3). , 2016, JAMA.

[14]  R. Abbott,et al.  Grading ERCPs by degree of difficulty: a new concept to produce more meaningful outcome data. , 2000, Gastrointestinal endoscopy.