On-line monitoring of chromium(III) using a fast micromachined mixer/reactor and chemiluminescence detection

A fast micromachined mixer/reactor was employed in a continuous flow injection set-up for the direct detection of chromium(III) in aqueous samples by chemiluminescence (CL). With the device Cr(III) can be detected at a concentration of 10−7 M and a linear calibration curve was obtained from 10−6 to 10−4 M Cr(III). In the continuous flow injection mode the system can perform fully automated detection with a reagent consumption of only 43.2 mL per day. In addition, a general theory is presented for the performance of diffusion-based mixer/reactor devices. This is the first report of the use of a micromachined device for the quantitative detection of Cr(III) with CL. Simple instrumentation, easy operation and low reagent consumption make this system a potential candidate for the in situ monitoring of Cr(III).

[1]  J. Posta,et al.  High-performance flow flame atomic absorption spectrometry for automated on-line separation and determination of chromium(III)/chromium(VI) and preconcentration of chromium(VI) , 1993 .

[2]  Larry J. Kricka,et al.  Chemiluminescent and bioluminescent methods in Analytical Chemistry. A review , 1983 .

[3]  V. Kabasakalis Fluorimetric Cr(VI) and Cr(III) speciation with crystal violet , 1993 .

[4]  M. Trojanowicz,et al.  Ion chromatographic speciation of chromium with diphenylcarbazide-based spectrophotometric detection , 1996 .

[5]  Philip Jones,et al.  Investigation of chromium(III) and chromium(VI) speciation in water by ion chromatography with chemiluminescence detection , 1994 .

[6]  J. Eijkel,et al.  Measuring Donnan-related phenomena using a solid-state ion sensor and a concentration-step method , 1997 .

[7]  D. Blowes,et al.  Chromium speciation and distribution in the great lakes. , 1994, Environmental science & technology.

[8]  Dolores Pérez-Bendito,et al.  Performance of the stopped-flow technique in chemiluminescence spectrometry based on direct rate measurements , 1989 .

[9]  A. Townshend Solution chemiluminescence—some recent analytical developments. Plenary lecture , 1990 .

[10]  J. Lind,et al.  Role of a peroxide intermediate in the chemiluminescence of luminol. A mechanistic study , 1980 .

[11]  J. Andersen Introduction of hydrogen peroxide as an oxidant in flow injection analysis: speciation of Cr(III) and Cr(VI) , 1998 .

[12]  K. Collins,et al.  Liquid chromatographic separation of aqueous species of Cr(VI) and Cr(III) , 1997 .

[13]  B. Gammelgaard,et al.  Simultaneous determination of chromium(III) and chromium(VI) in aqueous solutions by ion chromatography and chemiluminescence detection. , 1992, The Analyst.

[14]  H. B. Lim,et al.  Simultaneous Determination of Chromium(III) and Chromium(VI) in Aqueous Solution by Capillary Electrophoresis with On-Column UV-VIS Detection , 1997 .

[15]  F. F. Rosa,et al.  Flow injection chemiluminescence method for the selective determination of chromium(III) , 1993 .

[16]  A. Manz,et al.  Microstructure for efficient continuous flow mixing , 1999 .

[17]  E. Paleologos Speciation analysis of CrIII–CrVI using flow injection analysis with fluorimetric detection , 1998 .

[18]  T. Nieman,et al.  Immobilized luminol chemiluminescence reagent system for hydrogen peroxide determinations in flowing streams , 1988 .

[19]  J. Broekaert,et al.  Speciation of chromium by solid-phase extraction coupled to reversed-phase liquid chromatography with UV detection , 1998 .

[20]  P. Quevauviller,et al.  Cr(III) and Cr(VI) speciation measurements in environmental reference materials , 1996 .

[21]  B. Gammelgaard,et al.  Improvement on simultaneous determination of chromium species in aqueous solution by ion chromatography and chemiluminescence detection , 1997 .

[22]  W. Qin,et al.  Chemiluminescence flow-sensing system for hydrogen peroxide with immobilized reagents , 1998 .

[23]  F. F. Rosa,et al.  Determination of Trivalent and Hexavalent Chromium in Waste Water by Flow Injection Chemiluminescence Analysis , 1995 .

[24]  J. Caruso,et al.  Chromium speciation by anion-exchange high-performance liquid chromatography with both inductively coupled plasma atomic emission spectroscopic and inductively coupled plasma mass spectrometric detection. , 1995, Journal of chromatography. A.

[25]  B. Welz gSpeciation analysis. The future of atomic absorption spectrometry , 1998 .

[26]  R. Santelli,et al.  On the spectrophotometric flow injection determination of chromium(VI) in natural waters after on-line preconcentration on activated alumina. , 1995, Talanta.

[27]  W. Seitz,et al.  Determination of trace amounts of chromium(III) using chemiluminescence analysis , 1972 .