A Comparison of Three Methods for Trephining Donor Corneal Buttons: Endothelial Cell Loss and Microscopic Ultrastructural Evaluation

Purpose: To evaluate the ultrastructure of the cut edge and associated endothelial cell loss following donor cornea trephination with a standard punch, vacuum punch, and vacuum trephine and artificial anterior chamber system. Materials and Methods: This laboratory investigation compared trephinations (8.0 mm) performed on human corneas using either a standard posterior punch (n = 12), vacuum posterior punch (n = 12), or vacuum trephine and artificial anterior chamber system (n = 12). Specular microscopy was performed before and after trephination to determine central endothelial cell density. Light and scanning electron microscopy were performed to evaluate the structure of the trephined edge. Endothelial cell-free distances from the trephinated edges were measured on light microscopy sections. Results: Central endothelial cell loss (cells/mm2) after trephination was –14.0 ± 49.9 (SD) for the standard posterior punch, –85.6 ± 87.0 for the vacuum posterior punch, –116.0 ± 223.1 for the vacuum trephine and artificial anterior chamber system. Endothelial cell-free distances from the trephined margin were 63 ± 22 μm, 85 ± 13 μm, and 123 ± 48 μm for the three respective methods. The edges of grafts cut with anterior trephination were inward sloping from the epithelial to endothelial surfaces, while both posterior punches created outward sloping edges. Increased fibrillar disruption at edges was seen following anterior trephination. Conclusion: Different trephination methods produce distinct cut morphologies with the anterior trephination approach, resulting in more irregular margins. The anterior approach was associated with increased variability and greater endothelial cell loss than the studied posterior approaches. The use of corneal scissors may contribute to the morphologic features of the corneal button seen following anterior trephination.

[1]  R. Barraquer,et al.  Long-Term Progression of Astigmatism After Penetrating Keratoplasty for Keratoconus: Evidence of Late Recurrence , 2003, Cornea.

[2]  R. Olson,et al.  Penetrating keratoplasty for keratoconus: a long-term review of results and complications. , 2000, Journal of cataract and refractive surgery.

[3]  C. Skorpik,et al.  Effect of trephination technique on the ultrastructure of corneal transplants: guided trephine system vposterior punch technique , 1999, The British journal of ophthalmology.

[4]  J. Rowsey,et al.  The Tampa Trephine technique with cat corneal endothelium. , 1997, Cornea.

[5]  R C Troutman,et al.  Astigmatism after penetrating keratoplasty using the Krumeich guided trephine system. , 1993, Refractive & corneal surgery.

[6]  J. Parel,et al.  Endothelial damage by the corneal Hessburg-Barron vacuum trephine. , 1993, Refractive & corneal surgery.

[7]  T. Clinch,et al.  Corneal endothelial cell loss following trephination. , 1988, Ophthalmic surgery.

[8]  J. Parel,et al.  A suction trephine block for marking donor corneal buttons. , 1988, Archives of ophthalmology.

[9]  E. Guillet,et al.  Long-term changes in corneal endothelium following penetrating keratoplasty. A specular microscopic study. , 1983, Ophthalmology.

[10]  Bourne Wm Morphologic and functional evaluation of the endothelium of transplanted human corneas. , 1983, Transactions of the American Ophthalmological Society.

[11]  W. Bourne Morphologic and functional evaluation of the endothelium of transplanted human corneas. , 1983, Transactions of the American Ophthalmological Society.

[12]  R. Olson Corneal curvature changes associated with penetrating keratoplasty: a mathematical model. , 1980, Ophthalmic surgery.

[13]  R. Olson Variation in corneal graft size related to trephine technique. , 1979, Archives of ophthalmology.

[14]  Damiano Re,et al.  Trephination of donor corneal buttons: a scanning electron microscopic study. , 1978 .

[15]  F. Brightbill,et al.  A comparison of two methods for cutting donor corneal buttons. , 1973, American journal of ophthalmology.

[16]  I. C. Michaelson Slope of Sides of Corneal Grafts and Recipient Beds * , 1954, The British journal of ophthalmology.