A computer-controlled ventilator weaning system.

Weaning of patients from mechanical ventilation is a time-consuming, labor-intensive process. Because most weaning decisions are based on objective data, we tested a computer-directed weaning system on postoperative patients. We developed an automatic, computer-controlled ventilator weaning system which interfaces a laptop computer to a ventilator and a pulse oximeter. The laptop computer program accesses patient data through the ventilator and pulse oximeter to make weaning decisions. The computer directly controls the ventilator through an interface developed for this system. We tested the system in nine postoperative patients who met the following criteria: negative inspiratory force less than or equal to -20 cm H2O, vital capacity greater than 10 ml/kg, inspired oxygen concentration less than or equal to 40 percent, and satisfactory arterial blood gas parameters (pH between 7.32 and 7.48, PCO2 between 32 and 48, and oxygen saturation greater than or equal to 90 percent). The computer decreased the SIMV rate by 2 breaths/min every 5 min until a rate of 2 breaths/min was reached, then decreased pressure support by 4 cm H2O every 5 min as long as the patient met the following criteria: respiratory rate between 8 and 25 breaths/min, minute ventilation between 6 and 14 L, and pulse oximeter oxygen saturation greater than or equal to 90 percent. If unsatisfactory weaning criteria were noted, the system automatically returned the patient to the previous weaning level. We successfully weaned nine patients using the system. Additional studies are underway to determine if this system can be used in medical patients. We believe this computer-controlled ventilator weaning system can be used successfully in patients requiring mechanical ventilation and may decrease the time and cost associated with the care of these patients.

[1]  R. Smith,et al.  National survey of methods and criteria used for weaning from mechanical ventilation , 1987, Critical care medicine.

[2]  V. Moret-Bonillo,et al.  ESTER: an expert system for management of respiratory weaning therapy , 1989, IEEE Transactions on Biomedical Engineering.

[3]  C. Raymond Answering the call of 'high tech medicine': wedding engineering to healing art, science. , 1988, JAMA.

[4]  G. Barnett,et al.  DXplain. An evolving diagnostic decision-support system. , 1987, JAMA.

[5]  J. Marini Weaning from mechanical ventilation. , 1988, The New England journal of medicine.

[6]  N. MacIntyre,et al.  Respiratory function during pressure support ventilation. , 1986, Chest.

[7]  M. Tobin,et al.  A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation , 1991 .

[8]  K. Miller,et al.  A prospective comparison of IMV and T-piece weaning from mechanical ventilation. , 1989, Chest.

[9]  T. Petty,et al.  Weaning from mechanical ventilation. , 1976, JAMA.

[10]  H. Lorino,et al.  Inspiratory pressure support prevents diaphragmatic fatigue during weaning from mechanical ventilation. , 1989, The American review of respiratory disease.

[11]  E. Shortliffe Computer programs to support clinical decision making. , 1990, JAMA.

[12]  S. Allen,et al.  The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. , 2015, The American review of respiratory disease.