In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer.

The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

[1]  M. Weisend,et al.  Magnetoencephalography with a two color pump-probe fiber-coupled atomic magnetometer. , 2010 .

[2]  D. Budker,et al.  Optical magnetometry - eScholarship , 2006, physics/0611246.

[3]  Robert Wynands,et al.  Optimization and performance of an optical cardiomagnetometer , 2004, physics/0406157.

[4]  A. Bloom,et al.  Optical Detection of Magnetic Resonance in Alkali Metal Vapor , 1957 .

[5]  A. Bloom,et al.  OPTICALLY DRIVEN SPIN PRECESSION , 1961 .

[6]  Thomas G. Walker,et al.  Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array , 2011, Physics in medicine and biology.

[7]  Jiancheng Fang,et al.  Review of atomic MEMS: driving technologies and challenges , 2010 .

[8]  Three-component variometer based on a scalar potassium sensor , 2004 .

[9]  M. Romalis,et al.  Nuclear spin gyroscope based on an atomic comagnetometer. , 2005, Physical review letters.

[10]  Michael V. Romalis,et al.  Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer , 2004 .

[11]  Svenja Knappe,et al.  Femtotesla atomic magnetometry in a microfabricated vapor cell. , 2010, Optics express.

[12]  D Budker,et al.  Note: Detection of a single cobalt microparticle with a microfabricated atomic magnetometer. , 2011, The Review of scientific instruments.

[13]  Jiancheng Fang,et al.  Three-dimensional atomic magnetometry , 2012 .

[14]  M. Romalis,et al.  High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation. , 2002, Physical review letters.

[15]  R. Cecchi,et al.  Stray magnetic field compensation with a scalar atomic magnetometer. , 2010, The Review of scientific instruments.

[16]  R. Fagaly Superconducting quantum interference device instruments and applications , 2006 .

[17]  D. Budker,et al.  Spin-Exchange-Relaxation-Free Magnetometry with Cs Vapor , 2007, 0708.1012.

[18]  A. C. Maloof,et al.  Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer , 2009, 0910.2206.

[19]  Jiancheng Fang,et al.  Advances in Atomic Gyroscopes: A View from Inertial Navigation Applications , 2012, Sensors.

[20]  T. W. Kornack,et al.  A subfemtotesla multichannel atomic magnetometer , 2003, Nature.

[21]  D. Hoffman,et al.  Magnetoencephalography with an atomic magnetometer , 2006 .