Micron‐resolution ranging of cornea anterior chamber by optical reflectometry

Noncontact, high resolution measurements of anterior eye structures using optical coherence domain reflectometry are described. Distances between intraocular structures are measured by directing a beam of short coherence length light onto the eye and performing an interferometric measurement on the optical group delay of reflected signals. Measurements of corneal thickness, corneal excision depth, and anterior chamber depth are demonstrated in vitro, and the location of tissue boundaries is resolved to within ± 2 μm. The full‐width‐half‐maximum longitudinal resolution is 10 μm. Sensitivities to reflected signals as small as 10−10 of the incident power are achieved by heterodyne detection.

[1]  D. Davies,et al.  Optical coherence-domain reflectometry: a new optical evaluation technique. , 1987, Optics letters.

[2]  J. Kammann,et al.  Comparison of contact and immersion techniques for axial length measurement and implant power calculation , 1989, Journal of cataract and refractive surgery.

[3]  B R Frueh,et al.  Corneal thickness measured by interferometry. , 1975, Journal of the Optical Society of America.

[4]  F. K. Hansen,et al.  ON THE OPTICAL MEASUREMENT OF CORNEAL THICKNESS , 1971, Acta ophthalmologica.

[5]  A. Gordon,et al.  Variability of Ultrasonic Pachometry , 1990, Optometry and vision science : official publication of the American Academy of Optometry.

[6]  J G Fujimoto,et al.  Femtosecond optical ranging of corneal incision depth. , 1989, Investigative ophthalmology & visual science.

[7]  C K Hitzenberger,et al.  Optical measurement of the axial eye length by laser Doppler interferometry. , 1991, Investigative ophthalmology & visual science.

[8]  A. Fercher,et al.  Eye-length measurement by interferometry with partially coherent light. , 1988, Optics letters.

[9]  S. Trokel,et al.  Excimer laser surgery of the cornea. , 1983, American journal of ophthalmology.

[10]  J. Fujimoto,et al.  Femtosecond optical ranging in biological systems. , 1986, Optics letters.

[11]  S. Trokel,et al.  Excimer laser radial keratotomy. , 1985, Ophthalmology.

[12]  Heinz P. Weber,et al.  Optical reflectometry with micrometer resolution for the investigation of integrated optical devices , 1989 .

[13]  G O Waring,et al.  Wound healing after excimer laser keratomileusis (photorefractive keratectomy) in monkeys. , 1990, Archives of ophthalmology.

[14]  R. Webb,et al.  Flying spot TV ophthalmoscope. , 1980, Applied optics.

[15]  T. Olsen,et al.  The accuracy of ultrasonic determination of axial length in pseudophakic eyes , 1989, Acta ophthalmologica.