Calculation and Analysis of Transformer Inrush Current Based on Parameters of Transformer and Operating Conditions

An inrush current is a transient current with high amplitude that may occur when a transformer is energized under no load or lightly loaded conditions. The magnitude of inrush current may be as high as ten times or more times of transformer rated current. This could result in huge mechanical and thermal stresses on transformer in addition to inadvertent operation of the protective relay systems. This paper represents the effects of some factors on the inrush current of transformers. For this purpose, a one-phase transformer is simulated in MATLAB and the effects of switching angle variation, the energizing circuit impedance and the remanent flux on the characteristics of inrush current are investigated. The results show that increasing circuit resistance or switching angle will decrease inrush current amplitude. Also, it is concluded that for reducing inrush current, appropriate switching angle with respect to the remanent flux must be selected. The results can be used for a better understanding of the inrush current characteristics and proper actions of the protective system. Ill. 7, bibl. 13, tabl. 1 (in English; abstracts in English and Lithuanian). http://dx.doi.org/10.5755/j01.eee.109.3.162

[1]  I. F. Morrison,et al.  A Proposed Method of Harmonic Restraint Differential Protecting of Transformers by Digital Computer , 1972 .

[2]  Kuniaki Yabe,et al.  Power differential method for discrimination between fault and magnetizing inrush current in transformers , 1996 .

[3]  Jialong Wang,et al.  Analysis of Transformer Inrush Current and Comparison of Harmonic Restraint Methods in Transformer Protection , 2008, 2008 61st Annual Conference for Protective Relay Engineers.

[4]  G. D. Rockefeller,et al.  Magnetizing Inrush Phenomena in Transformer Banks , 1958, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[5]  S. Cabral,et al.  Semianalytic Solution for a Simple Model of Inrush Currents in Transformers , 2008, IEEE Transactions on Magnetics.

[6]  G.B. Gharehpetian,et al.  An Algorithm for Evaluating Inrush Current in Transformers Using Jiles-Atherton Theory of Ferromagnetic Hysteresis , 2006, TENCON 2006 - 2006 IEEE Region 10 Conference.

[7]  Wilsun Xu,et al.  Analytical Formula to Estimate the Maximum Inrush Current , 2008, IEEE Transactions on Power Delivery.

[8]  H. W. Kerr,et al.  Large power transformers , 1964 .

[9]  J. Faiz,et al.  A novel wavelet-based algorithm for discrimination of internal faults from magnetizing inrush currents in power transformers , 2006, IEEE Transactions on Power Delivery.

[10]  R.-L. Lin,et al.  Magnetizing inrush model of transformers based on structure parameters , 2005, IEEE Transactions on Power Delivery.

[11]  Bogdan Kasztenny,et al.  An Improved Transformer Inrush Restraint Algorithm , 2002 .

[12]  Randy Hamilton,et al.  Analysis of transformer inrush current and comparison of harmonic restraint methods in transformer protection , 2012, 2012 Petroleum and Chemical Industry Conference (PCIC).