Time-resolved mass concentration, composition and sources of aerosol particles in a metropolitan underground railway station

Abstract Aerosol samples were collected using a stacked filter unit (SFU) for PM10-2.0 and PM2.0 size fractions on the platform of a metropolitan underground railway station in downtown Budapest. Temporal variations in the PM10 mass concentration and wind speed and direction were determined with time resolutions of 30 and 4 s using a tapered-element oscillating microbalance (TEOM) and a wind monitor, respectively. Sample analysis involved gravimetry for particulate mass, and particle-induced X-ray emission spectrometry (PIXE) for elemental composition. Diurnal variation of the PM10 mass concentration exhibited two peaks, one at approximately 07:00 h and the other at approximately 17:00 h. The mean±SD PM10 mass concentration for working hours was 155±55 μg m −3 . Iron, Mn, Ni, Cu, and Cr concentrations were higher than in outdoor air by factors between 5 and 20, showing substantial enrichment compared to both the average crustal rock composition and the average outdoor aerosol composition. Iron accounted for 40% and 46% of the PM10-2.0 and PM2.0 masses, respectively, and 72% of the PM10 mass was associated with the PM10-2.0 size fraction. The aerosol composition in the metro station (in particular the abundance of the metals mentioned above) is quite different from the average outdoor downtown composition. Mechanical wear and friction of electric conducting rails and bow sliding collectors, ordinary rails and wheels, as well as resuspension, were identified as the primary sources. Possible health implications based on comparison to various limit values and to data available for other underground railways are discussed.

[1]  Mark Seaver,et al.  Aerosol Characteristics in a Subway Environment , 2003 .

[2]  Sonja N Sax,et al.  Elevated airborne exposures of teenagers to manganese, chromium, and iron from steel dust and New York City's subway system. , 2004, Environmental science & technology.

[3]  R. Duce,et al.  Atmospheric Concentrations and Sources of Trace Metals at the South Pole , 1974, Science.

[4]  A Magrini,et al.  Dust in the Underground Railway Tunnels of an Italian Town , 2006, Journal of occupational and environmental hygiene.

[5]  Yoichi Araki,et al.  SEASONAL VARIATION AND THEIR CHARACTERIZATION OF SUSPENDED PARTICULATE MATTER IN THE AIR OF SUBWAY STATIONS , 2001 .

[6]  G D Pfeifer,et al.  Personal exposures to airborne metals in London taxi drivers and office workers in 1995 and 1996. , 1999, The Science of the total environment.

[7]  P. L. Jenkins,et al.  Activity patterns of Californians: Use of and proximity to indoor pollutant sources , 1992 .

[8]  Christer Johansson,et al.  Particulate matter in the underground of Stockholm , 2002 .

[9]  J. Lodge Air quality guidelines for Europe: WHO regional publications, European series, No. 23, World Health Organization, 1211 Geneva 27, Switzerland; WHO publications center USA, 49 Sheridan Avenue, Albany, NY 12210, 1987, xiii + 426 pp. price: Sw. fr. 60 , 1988 .

[10]  Combined application of INAA and PIXE for studying the regional aerosol composition in Southern Africa , 1997 .

[11]  J. W. Winchester,et al.  PIXE analysis of aerosol samples collected over the atlantic ocean from a sailboat , 1981 .

[12]  John L. Gras,et al.  TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations , 1999 .

[13]  W. MacNee,et al.  Free radical activity of PM10: iron-mediated generation of hydroxyl radicals. , 1997, Environmental health perspectives.

[14]  Ian D. Williams,et al.  Characterisation of airborne particles in London by computer-controlled scanning electron microscopy , 1999 .

[15]  Martin Braniš,et al.  The contribution of ambient sources to particulate pollution in spaces and trains of the Prague underground transport system , 2006 .

[16]  A Seaton,et al.  The London Underground: dust and hazards to health , 2005, Occupational and Environmental Medicine.

[17]  W. Maenhaut,et al.  Comprehensive characterisation of atmospheric aerosols in Budapest, Hungary: physicochemical properties of inorganic species , 2001 .

[18]  H Fromme,et al.  Polycyclic aromatic hydrocarbons (PAH) and diesel engine emission (elemental carbon) inside a car and a subway train. , 1998, The Science of the total environment.

[19]  L. Closs Principles of Geochemistry (Fourth Edition): Brian Mason and Carleton B. Moore, John Wiley, New York, 1982, 344 p., $29.95. (also available in paperback in the Wiley International Edition Series at £7.25/$12.35.) , 1983 .

[20]  John D. Spengler,et al.  Steel dust in the New York City subway system as a source of manganese, chromium, and iron exposures for transit workers , 2005, Journal of Urban Health.

[21]  R. Colvile,et al.  Fine particle (PM2.5) personal exposure levels in transport microenvironments, London, UK. , 2001, The Science of the total environment.

[22]  B. Mason Principles of geochemistry , 1958 .

[23]  J. Cafmeyer,et al.  The ''Gent'' stacked filter unit (SFU) sampler for the collection of atmospheric aerosols in two size fractions: Description and instructions for installation and use , 1994 .

[24]  Timo Mäkelä,et al.  The concentrations and composition of and exposure to fine particles (PM2.5) in the Helsinki subway system , 2005 .

[25]  Sheldon Landsberger,et al.  Characterization of the Gent Stacked Filter Unit PM10 Sampler , 1997 .

[26]  J. Fenger,et al.  Urban air quality , 1999 .

[27]  Abdel Hameed A. Awad,et al.  Environmental Study in Subway Metro Stations in Cairo, Egypt , 2002 .

[28]  W. Maenhaut,et al.  Changes in elemental composition and mass of atmospheric aerosol pollution between 1996 and 2002 in a Central European city. , 2006, Environmental pollution.

[29]  L Szám,et al.  [Airborne microflora found in some stations of the metro in the Hungarian capital of Budapest (author's transl)]. , 1980, Zentralblatt fur Bakteriologie. 1. Abt. Originale B, Hygiene, Krankenhaushygiene, Betriebshygiene, praventive Medizin.

[30]  J. Cafmeyer,et al.  Chemical composition and mass closure for fine and coarse aerosols at a kerbside in Budapest, Hungary, in spring 2002 , 2005 .