Control strategy for AC-DC microgrid with hybrid energy storage under different operating modes

Abstract In this paper, a control strategy is proposed for renewable-interfaced hybrid energy storage system (HESS) under grid connected/islanding conditions. A second harmonic based phased locked loop (PLL) is employed for effective synchronization/resynchronization of the microgrid system under contingency conditions. The operation and management of the microgrid system under both these modes are accomplished by an efficient adaptive power management algorithm. A quantitative analysis on the HESS performance is provided in order to investigate the effectiveness of the proposed approach. Further, small signal average models are derived to comment on the system stability. This approach address seamless transfer between the various sub-modes of the system along with additional services such as power quality enhancement and power dispatch between various sources. The effectiveness of the proposed scheme is verified by both simulation and experimental investigations.

[1]  Bangyin Liu,et al.  An Islanding Detection Method Based on Dual-Frequency Harmonic Current Injection Under Grid Impedance Unbalanced Condition , 2013, IEEE Transactions on Industrial Informatics.

[2]  Ehab F. El-Saadany,et al.  A Universal Islanding Detection Technique for Distributed Generation Using Pattern Recognition , 2014, IEEE Transactions on Smart Grid.

[3]  Gabriel Garcera,et al.  An Active Anti-Islanding Method Based on Phase-PLL Perturbation , 2011, IEEE Transactions on Power Electronics.

[4]  R Noroozian,et al.  A New Method for Islanding Detection of Inverter-Based Distributed Generation Using DC-Link Voltage Control , 2011, IEEE Transactions on Power Delivery.

[5]  Rachid Beguenane,et al.  Energy Management and Control System for Laboratory Scale Microgrid Based Wind-PV-Battery , 2017, IEEE Transactions on Sustainable Energy.

[6]  Jin Jiang,et al.  A Power Management Strategy for PV/Battery Hybrid Systems in Islanded Microgrids , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[7]  Baoming Ge,et al.  Energy storage system-based power control for grid-connected wind power farm , 2013 .

[8]  Keyue Smedley,et al.  Anti-Islanding for Three-Phase One-Cycle Control Grid Tied Inverter , 2014, IEEE Transactions on Power Electronics.

[9]  A Hajizadeh,et al.  Voltage Control and Active Power Management of Hybrid Fuel-Cell/Energy-Storage Power Conversion System Under Unbalanced Voltage Sag Conditions , 2010, IEEE Transactions on Energy Conversion.

[10]  Reza Noroozian,et al.  Design of a multilevel control strategy for integration of stand-alone wind/diesel system , 2012 .

[11]  Stephen J. Finney,et al.  Harmonic distortion-based island detection technique for inverter-based distributed generation , 2009 .

[12]  Chung-Yuen Won,et al.  An Islanding Detection Method for a Grid-Connected System Based on the Goertzel Algorithm , 2011, IEEE Transactions on Power Electronics.

[13]  Vassilios G. Agelidis,et al.  A Model Predictive Control System for a Hybrid Battery-Ultracapacitor Power Source , 2014, IEEE Transactions on Power Electronics.

[14]  Vassilios G. Agelidis,et al.  A Low Complexity Control System for a Hybrid DC Power Source Based on Ultracapacitor–Lead–Acid Battery Configuration , 2014, IEEE Transactions on Power Electronics.

[15]  M. Karrari,et al.  Adaptive Fuzzy Sandia Frequency-Shift Method for Islanding Protection of Inverter-Based Distributed Generation , 2013, IEEE Transactions on Power Delivery.

[16]  Dehong Xu,et al.  A Novel RPV (Reactive-Power-Variation) Antiislanding Method Based on Adapted Reactive Power Perturbation , 2013, IEEE Transactions on Power Electronics.

[17]  T.S. Sidhu,et al.  Evaluation of Two Anti-Islanding Schemes for a Radial Distribution System Equipped With Self-Excited Induction Generator Wind Turbines , 2010, IEEE Transactions on Energy Conversion.

[18]  Wei Li,et al.  Real-Time Simulation of a Wind Turbine Generator Coupled With a Battery Supercapacitor Energy Storage System , 2010, IEEE Transactions on Industrial Electronics.

[19]  Bin Wu,et al.  Improved Active Frequency Drift Anti-islanding Detection Method for Grid Connected Photovoltaic Systems , 2012, IEEE Transactions on Power Electronics.

[20]  Di Lu,et al.  Application of Petri nets for the energy management of a photovoltaic based power station including storage units , 2010 .

[21]  He Yin,et al.  Quantitative Efficiency and Temperature Analysis of Battery-Ultracapacitor Hybrid Energy Storage Systems , 2016, IEEE Transactions on Sustainable Energy.

[22]  R. Iravani,et al.  Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit , 2008, IEEE Transactions on Power Electronics.

[23]  Dehong Xu,et al.  A novel RPV (reactive-power-variation) anti-islanding method based on adapted reactive power perturbation , 2012, 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[24]  Javad Sadeh,et al.  Islanding detection method for photovoltaic distributed generation based on voltage drifting , 2013 .