A Response Surface Approach to Beam Orientation Optimization in Intensity-Modulated Radiation Therapy Treatment Planning

We view the beam orientation optimization (BOO) problem in intensity-modulated radiation therapy (IMRT) treatment planning as a global optimization problem with expensive objective function evaluations. We propose a response surface method that, in contrast with other approaches, allows for the generation of problem data only for promising beam orientations as the algorithm progresses. This enables the consideration of additional degrees of freedom in the treatment delivery, i.e., many more candidate beam orientations than is possible with existing approaches to BOO. This ability allows us to include noncoplanar beams and consider the question of whether or not noncoplanar beams can provide significant improvement in treatment plan quality. We also show empirically that using our approach, we can generate clinically acceptable treatment plans that require fewer beams than are used in current practice.

[1]  L. Xing,et al.  Incorporating prior knowledge into beam orientation optimization in IMRT. , 2002, International journal of radiation oncology, biology, physics.

[2]  Sebastiaan Breedveld,et al.  A novel approach to multi-criteria inverse planning for IMRT , 2007, Physics in medicine and biology.

[3]  Arvind Kumar,et al.  Neighborhood search approaches to beam orientation optimization in intensity modulated radiation therapy treatment planning , 2008, J. Glob. Optim..

[4]  C G Rowbottom,et al.  A case study comparing the relative benefit of optimizing beam weights, wedge angles, beam orientations and tomotherapy in stereotactic radiotherapy of the brain. , 1998, Physics in medicine and biology.

[5]  H. Romeijn,et al.  A unifying framework for multi-criteria fluence map optimization models. , 2004, Physics in medicine and biology.

[6]  Tibor Csendes,et al.  Multisection in Interval Branch-and-Bound Methods for Global Optimization – I. Theoretical Results , 2000, J. Glob. Optim..

[7]  HOANG TUY,et al.  On Solving Nonconvex Optimization Problems by Reducing The Duality Gap , 2005, J. Glob. Optim..

[8]  K. Burnham,et al.  Optimization of beam orientation in radiotherapy using planar geometry. , 1998, Physics in medicine and biology.

[9]  B. Murray,et al.  The development of target-eye-view maps for selection of coplanar or noncoplanar beams in conformal radiotherapy treatment planning. , 1999, Medical physics.

[10]  Le Thi Hoai An,et al.  Decomposition branch and bound method for globally solving linearly constrained indefinite quadratic minimization problems , 1995, Oper. Res. Lett..

[11]  Efstratios N. Pistikopoulos,et al.  A Reduced Space Branch and Bound Algorithm for Global optimization , 1997, J. Glob. Optim..

[12]  Eva K. Lee,et al.  Integer Programming Applied to Intensity-Modulated Radiation Therapy Treatment Planning , 2003, Ann. Oper. Res..

[13]  Fernando Alonso,et al.  A new concept for interactive radiotherapy planning with multicriteria optimization: first clinical evaluation. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  RICCARDO CAMBINI,et al.  Decomposition Methods for Solving Nonconvex Quadratic Programs via Branch and Bound* , 2005, J. Glob. Optim..

[15]  C G Rowbottom,et al.  Beam-orientation customization using an artificial neural network. , 1999, Physics in medicine and biology.

[16]  Anders Brahme,et al.  Selection of suitable beam orientations in radiation therapy using entropy and Fourier transform measures , 1992 .

[17]  Eva K. Lee,et al.  Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[18]  M. Goitein,et al.  Multi-dimensional treatment planning: II. Beam's eye-view, back projection, and projection through CT sections. , 1983, International journal of radiation oncology, biology, physics.

[19]  Radhe Mohan,et al.  Iterative solution methods for beam angle and fluence map optimization in intensity modulated radiation therapy planning , 2008, OR Spectr..

[20]  Donald R. Jones,et al.  Efficient Global Optimization of Expensive Black-Box Functions , 1998, J. Glob. Optim..

[21]  I I Rosen,et al.  Treatment planning optimization using constrained simulated annealing. , 1991, Physics in medicine and biology.

[22]  C. Pelizzari,et al.  The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals. , 1992, International journal of radiation oncology, biology, physics.

[23]  Nguyen V. Thoai Convergence of duality bound method in partly convex programming , 2002, J. Glob. Optim..

[24]  H. Romeijn,et al.  A novel linear programming approach to fluence map optimization for intensity modulated radiation therapy treatment planning. , 2003, Physics in medicine and biology.

[25]  H. Edwin Romeijn,et al.  Beam Orientation Optimization Methods in Intensity Modulated Radiation Therapy Treatment Planning , 2008 .

[26]  T. Bortfeld,et al.  Number and orientations of beams in intensity-modulated radiation treatments. , 1997, Medical physics.

[27]  C G Rowbottom,et al.  Improvements in prostate radiotherapy from the customization of beam directions. , 1998, Medical physics.

[28]  T. Bortfeld,et al.  Optimization of beam orientations in radiation therapy: some theoretical considerations. , 1993, Physics in medicine and biology.

[29]  Donald R. Jones,et al.  A Taxonomy of Global Optimization Methods Based on Response Surfaces , 2001, J. Glob. Optim..

[30]  G A Ezzell,et al.  Genetic and geometric optimization of three-dimensional radiation therapy treatment planning. , 1996, Medical physics.

[31]  Lei Dong,et al.  Development of methods for beam angle optimization for IMRT using an accelerated exhaustive search strategy. , 2004, International journal of radiation oncology, biology, physics.

[32]  Y. Li,et al.  Automatic beam angle selection in IMRT planning using genetic algorithm. , 2004, Physics in medicine and biology.

[33]  David Craft,et al.  An approach for practical multiobjective IMRT treatment planning. , 2007, International journal of radiation oncology, biology, physics.

[34]  Radhe Mohan,et al.  Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinoma. , 2005, International journal of radiation oncology, biology, physics.

[35]  Immanuel M. Bomze,et al.  Branch-and-bound approaches to standard quadratic optimization problems , 2002, J. Glob. Optim..

[36]  Jean-Louis Lagouanelle,et al.  Optimal Multisections in Interval Branch-and-Bound Methods of Global Optimization , 2004, J. Glob. Optim..

[37]  Oscar Barrientos,et al.  An Algorithm for Global Minimization of Linearly Constrained Quadratic Functions* , 2000, J. Glob. Optim..

[38]  A. Brahme,et al.  Which is the most suitable number of photon beam portals in coplanar radiation therapy? , 1995, International journal of radiation oncology, biology, physics.

[39]  L. Xing,et al.  Pseudo beam's-eye-view as applied to beam orientation selection in intensity-modulated radiation therapy. , 2001, International journal of radiation oncology, biology, physics.

[40]  C G Rowbottom,et al.  Constrained customization of non-coplanar beam orientations in radiotherapy of brain tumours. , 1999, Physics in medicine and biology.

[41]  Bill J. Salter,et al.  A Tutorial on Radiation Oncology and Optimization , 2005 .

[42]  H Edwin Romeijn,et al.  Fast voxel and polygon ray-tracing algorithms in intensity modulated radiation therapy treatment planning. , 2006, Medical physics.

[43]  L B Marks,et al.  Selection of coplanar or noncoplanar beams using three-dimensional optimization based on maximum beam separation and minimized nontarget irradiation. , 1997, International journal of radiation oncology, biology, physics.

[44]  Wufan Chen,et al.  A particle swarm optimization algorithm for beam angle selection in intensity-modulated radiotherapy planning , 2005, Physics in medicine and biology.

[45]  A Pugachev,et al.  Computer-assisted selection of coplanar beam orientations in intensity-modulated radiation therapy. , 2001, Physics in medicine and biology.

[46]  Radhe Mohan,et al.  Algorithm and performance of a clinical IMRT beam-angle optimization system. , 2003, Physics in medicine and biology.

[47]  E. Woudstra,et al.  Automated beam angle and weight selection in radiotherapy treatment planning applied to pancreas tumors. , 2003, International journal of radiation oncology, biology, physics.

[48]  H M Kooy,et al.  Optimized beam planning for linear accelerator-based stereotactic radiosurgery. , 1997, International journal of radiation oncology, biology, physics.

[49]  M. Alber,et al.  Non-coplanar beam direction optimization for intensity-modulated radiotherapy. , 2003, Physics in medicine and biology.

[50]  L. Xing,et al.  Multiobjective evolutionary optimization of the number of beams, their orientations and weights for intensity-modulated radiation therapy , 2004, Physics in Medicine and Biology.