Cataract surgery and methods of wound closure: a review

Clear corneal incisions are routinely used in cataract surgery, but watertight wound closure may not always be achieved, which can increase the risk for anterior chamber fluid egress or ocular surface fluid ingress. A new US Food and Drug Administration-approved ocular sealant appears to have good efficacy in sealing clear corneal incisions; its use may be indicated when wound integrity is in question.

[1]  P. Cockcroft,et al.  Bacterial contamination of nylon corneal sutures , 1995, Eye.

[2]  H. Faulkner Association between clear corneal cataract incisions and postoperative endophthalmitis. , 2007, Journal of cataract and refractive surgery.

[3]  A. Behrens,et al.  Inflow of ocular surface fluid through clear corneal cataract incisions: a laboratory model. , 2005, American journal of ophthalmology.

[4]  Use of a calibrated force gauge in clear corneal cataract surgery to quantify point‐pressure manipulation , 2013, Journal of cataract and refractive surgery.

[5]  Terry Kim,et al.  Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery , 2014, Journal of cataract and refractive surgery.

[6]  Wound instability and management after cataract surgery in a patient with prior laser in situ keratomileusis. , 2007, Journal of cataract and refractive surgery.

[7]  M. Coroneo,et al.  Obviating endophthalmitis after cataract surgery: excellent wound closure is the key. , 2011, Archives of ophthalmology.

[8]  Emily W. Gower,et al.  Bacterial‐sized particle inflow through sutured clear corneal incisions in a laboratory human model , 2011, Journal of cataract and refractive surgery.

[9]  J. Hovanesian,et al.  Watertight cataract incision closure using fibrin tissue adhesive , 2007, Journal of cataract and refractive surgery.

[10]  S. Chee Clear corneal incision leakage after phacoemulsification––detection using povidone iodine 5% , 2007, International Ophthalmology.

[11]  İ. Can,et al.  Anterior segment optical coherence tomography evaluation and comparison of main clear corneal incisions in microcoaxial and biaxial cataract surgery , 2011, Journal of cataract and refractive surgery.

[12]  M. Coroneo,et al.  Miyake–Apple study of the rotational stability of the Acrysof toric intraocular lens after experimental eye trauma , 2010, Eye.

[13]  A. Vasavada,et al.  Effect of stromal hydration of clear corneal incisions: Quantifying ingress of trypan blue into the anterior chamber after phacoemulsification , 2007, Journal of cataract and refractive surgery.

[14]  Zhongping Chen,et al.  Dynamic morphology of clear corneal cataract incisions. , 2003, Ophthalmology.

[15]  A. Behrens,et al.  Sutured Clear Corneal Incision: Wound Apposition and Permeability to Bacterial-Sized Particles , 2013, Cornea.

[16]  J. Elisseeff,et al.  Synthesis and characterization of a chondroitin sulfate‐polyethylene glycol corneal adhesive , 2009, Journal of cataract and refractive surgery.

[17]  D. Grewal,et al.  Intraoperative vertical gas breakthrough during clear corneal incision creation with the femtosecond cataract laser. , 2014, Journal of cataract and refractive surgery.

[18]  Vivek B. Pandya,et al.  Endophthalmitis following cataract surgery: the sucking corneal wound. , 2009, Journal of cataract and refractive surgery.

[19]  J. Alió,et al.  Evaluation of a New Bioadhesive Copolymer (ADAL®) to Seal Corneal Incisions , 2004, Cornea.

[20]  W. Camacho,et al.  Analysis of clear corneal incision integrity in an ex vivo model , 2008, Journal of cataract and refractive surgery.

[21]  V. Tanner,et al.  Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture , 2009, Journal of cataract and refractive surgery.

[22]  Motoaki Yoshida,et al.  Intraocular pressure and wound status in eyes immediately after scleral tunnel incision and clear corneal incision cataract surgery. , 2014, American journal of ophthalmology.

[23]  J. Lloyd,et al.  Incidence of postoperative endophthalmitis in a high-volume cataract surgicentre in Canada. , 2009, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[24]  Yuki,et al.  Clinical Ophthalmology , 2000, The British journal of ophthalmology.

[25]  S. Masket,et al.  Proper wound construction to prevent short‐term ocular hypotony after clear corneal incision cataract surgery , 2007, Journal of cataract and refractive surgery.

[26]  A. Behrens,et al.  Novel laser-activated solder for sealing corneal wounds. , 2007, Investigative ophthalmology & visual science.

[27]  M. Kinsella,et al.  Study of fluid ingress through clear corneal incisions following phacoemulsification with or without the use of a hydrogel ocular bandage: a prospective comparative randomised study , 2014, Acta ophthalmologica.

[28]  B. A. Stratas Clear corneal paracentesis: a case of chronic wound leakage in a patient having bimanual phacoemulsification. , 2005, Journal of cataract and refractive surgery.

[29]  H. Edelhauser,et al.  Sealability of ultrashort‐pulse laser and manually generated full‐thickness clear corneal incisions , 2014, Journal of cataract and refractive surgery.

[30]  D. Lam,et al.  Inflow of ocular surface fluid through clear corneal cataract incisions: a laboratory model. , 2005, American journal of ophthalmology.

[31]  Scott D. Smith,et al.  Suture-related corneal infections after clear corneal cataract surgery. , 2009, Journal of cataract and refractive surgery.

[32]  Chung-Tien Lin,et al.  Comparison of the Bacteriostatic Effects, Corneal Cytotoxicity, and the Ability to Seal Corneal Incisions Among Three Different Tissue Adhesives , 2007, Cornea.

[33]  M. Banitt,et al.  Wound Integrity of Clear Corneal Incisions Closed with Fibrin and N-Butyl-2-Cyanoacrylate Adhesives , 2009, Current eye research.

[34]  P. McDonnell,et al.  Seidel and India ink tests assessment of different clear cornea side-port incision configurations , 2013, Graefe's Archive for Clinical and Experimental Ophthalmology.

[35]  D. Musch,et al.  Postoperative endophthalmitis associated with sutured versus unsutured clear corneal cataract incisions , 2007, British Journal of Ophthalmology.

[36]  A. Spierer,et al.  Suture‐related complications after congenital cataract surgery: Vicryl versus Mersilene sutures , 2007, Journal of cataract and refractive surgery.

[37]  S. Masket,et al.  Randomized comparison of postoperative use of hydrogel ocular bandage and collagen corneal shield for wound protection and patient tolerability after cataract surgery , 2011, Journal of cataract and refractive surgery.

[38]  Helder Marçal,et al.  Sutureless sealing of penetrating corneal wounds using a laser‐activated thin film adhesive , 2011, Lasers in surgery and medicine.

[39]  Saad A Waheeb Topical anesthesia in phacoemulsification , 2010, Oman journal of ophthalmology.

[40]  Incisions , 1975, The Laryngoscope.

[41]  Comparison of wound strength with and without a hydrogel liquid ocular bandage in human cadaver eyes , 2010, Journal of cataract and refractive surgery.

[42]  R. Bragadóttir,et al.  Total iris expulsion through a sutureless cataract incision due to vomiting. , 2005, Acta ophthalmologica Scandinavica.

[43]  R. Olson,et al.  Cohort study of 27 cases of endophthalmitis at a single institution , 2005, Journal of cataract and refractive surgery.

[44]  W. Mieler,et al.  COMPLICATIONS ASSOCIATED WITH CLEAR CORNEAL CATARACT WOUNDS DURING VITRECTOMY , 2010, Retina.

[45]  S. Schneider,et al.  Liquid bandage (2-octyl cyanoacrylate) as a temporary wound barrier in clear corneal cataract surgery. , 2005, Ophthalmology.

[46]  Subir Bhatia Ocular surface sealants and adhesives. , 2006, The ocular surface.

[47]  Terry Kim,et al.  Tissue adhesives in corneal cataract incisions , 2007, Current opinion in ophthalmology.

[48]  I. Francis,et al.  Role of adequate wound closure in preventing acute postoperative bacterial endophthalmitis. , 2012, Journal of cataract and refractive surgery.

[49]  D. Coleman,et al.  Direct-recorded intraocular pressure variations in a human subject. , 1969, Archives of ophthalmology.

[50]  Y. Yasuno,et al.  Wound architecture of clear corneal incision with or without stromal hydration observed with 3-dimensional optical coherence tomography. , 2011, American journal of ophthalmology.

[51]  D. Azar,et al.  Photochemical keratodesmos for bonding corneal incisions. , 2004, Investigative ophthalmology & visual science.

[52]  R. Hoffman,et al.  Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography , 2007, Journal of cataract and refractive surgery.

[53]  R. Packard,et al.  Adherent ocular bandage for clear corneal incisions used in cataract surgery , 2010, Journal of cataract and refractive surgery.

[54]  S. Kelly,et al.  Suture-related complications after cataract surgery: a patient safety issue. , 2009, Journal of cataract and refractive surgery.

[55]  R. Packard,et al.  Clear corneal incision architecture in the immediate postoperative period evaluated using optical coherence tomography , 2007, Journal of cataract and refractive surgery.

[56]  A. Vasavada,et al.  Incision integrity and postoperative outcomes after microcoaxial phacoemulsification performed using 2 incision‐dependent systems , 2013, Journal of cataract and refractive surgery.

[57]  Terry Kim,et al.  In vitro sealing of clear corneal cataract incisions with a novel biodendrimer adhesive. , 2009, Archives of ophthalmology.

[58]  L. Mastropasqua,et al.  Femtosecond laser versus manual clear corneal incision in cataract surgery. , 2014, Journal of refractive surgery.

[59]  T. Walters The effect of stromal hydration on surgical outcomes for cataract patients who received a hydrogel ocular bandage , 2011, Clinical ophthalmology.

[60]  Adnan Kurt,et al.  Corneal Tissue Welding With Infrared Laser Irradiation After Clear Corneal Incision , 2010, Cornea.

[61]  A. Neves,et al.  Postcataract Surgery Endophthalmitis after Introduction of the ESCRS Protocol: A 5-year Study , 2014, European journal of ophthalmology.

[62]  S. Masket,et al.  ASCRS White Paper: What is the association between clear corneal cataract incisions and postoperative endophthalmitis? , 2006, Journal of cataract and refractive surgery.

[63]  김태임,et al.  Fourier-domain optical coherence tomography evaluation of clear corneal incision structure according to blade material , 2014 .

[64]  Emily W. Gower,et al.  Standardized Seidel test to evaluate different sutureless cataract incision configurations , 2010, Journal of cataract and refractive surgery.

[65]  K. Kenyon,et al.  Surgical outcomes after application of a liquid adhesive ocular bandage to clear corneal incisions during cataract surgery , 2013, Journal of cataract and refractive surgery.

[66]  U. Stenevi,et al.  Endophthalmitis after cataract surgery: a nationwide prospective study evaluating incidence in relation to incision type and location. , 2007, Ophthalmology.