Optimization of a Miniature Maglev Ventricular Assist Device for Pediatric Circulatory Support

A miniature Maglev blood pump based on magnetically levitated bearingless technology is being developed and optimized for pediatric patients. We performed impeller optimization by characterizing the hemodynamic and hemocompatibility performances using a combined computational and experimental approach. Both three-dimensional flow features and hemolytic characteristics were analyzed using computational fluid dynamics (CFD) modeling. Hydraulic pump performances and hemolysis levels of three different impeller designs were quantified and compared numerically. Two pump prototypes were constructed from the two impeller designs and experimentally tested. Comparison of CFD predictions with experimental results showed good agreement. The optimized impeller remarkably increased overall pump hydraulic output by more than 50% over the initial design. The CFD simulation demonstrated a clean and streamlined flow field in the main flow path. The numerical results by hemolysis model indicated no significant high shear stress regions. Through the use of CFD analysis and bench-top testing, the small pediatric pump was optimized to achieve a low level of blood damage and improved hydraulic performance and efficiency. The Maglev pediatric blood pump is innovative due to its small size, very low priming volume, excellent hemodynamic and hematologic performance, and elimination of seal-related and bearing-related failures due to adoption of magnetically levitated bearingless motor technology, making it ideal for pediatric applications.

[1]  Young I. Cho,et al.  A method of isolating surface tension and yield stress effects in a U-shaped scanning capillary-tube viscometer using a Casson model , 2002 .

[2]  B. Duncan Mechanical Support for Cardiac and Respiratory Failure in Pediatric Patients , 2001 .

[3]  A. Chang,et al.  Bridge to transplant using the MicroMed DeBakey ventricular assist device in a child with idiopathic dilated cardiomyopathy. , 2006, The Annals of thoracic surgery.

[4]  J. Copeland,et al.  Pediatric bridge to heart transplantation: application of the Berlin Heart, Medos and Thoratec ventricular assist devices. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  P. D. del Nido,et al.  Mechanical circulatory support in children with cardiac disease. , 1999, The Journal of thoracic and cardiovascular surgery.

[6]  Reto Schöb Centrifugal pump without bearings or seals , 2002 .

[7]  Reto Schöb,et al.  Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device. , 2004, Artificial organs.

[8]  B. Reichart,et al.  Mechanical circulatory support in infants and adults with the MEDOS/HIA assist device. , 2005, Artificial organs.

[9]  Bartley P Griffith,et al.  Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump. , 2006, Artificial organs.

[10]  H. Reul,et al.  Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves , 1990, The International journal of artificial organs.

[11]  Xinwei Song,et al.  A prototype HeartQuest ventricular assist device for particle image velocimetry measurements. , 2002, Artificial organs.

[12]  D. Wheeldon Mechanical circulatory support: state of the art and future perspectives , 2003, Perfusion.

[13]  S. Cowin,et al.  Biomechanics: Mechanical Properties of Living Tissues, 2nd ed. , 1994 .

[14]  Leslie Hamilton,et al.  The waiting game: bridging to paediatric heart transplantation. , 2003, Lancet.

[15]  C Bludszuweit,et al.  Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. , 1995, Artificial organs.

[16]  Harvey S Borovetz,et al.  The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program. , 2005, Circulation.

[17]  D. Farrar,et al.  Thoratec Ventricular Assist Devices in Pediatric Patients: Update on Clinical Results , 2005, ASAIO journal.

[18]  B. Reitz,et al.  Successful bridge to transplant using the Berlin Heart left ventricular assist device in a 3-month-old infant. , 2006, The Annals of thoracic surgery.