Combined Flux Observer With Signal Injection Enhancement for Wide Speed Range Sensorless Direct Torque Control of IPMSM Drives

This paper proposes a motion-sensorless control system using direct torque control with space vector modulation for interior permanent magnet synchronous motor (IPMSM) drives, for wide speed range operation, including standstill. A novel stator flux observer with variable structure uses a combined voltage-current model with PI compensator for low-speed operations. As speed increases, the observer switches gradually to a PI compensated closed-loop voltage model, which is solely used at high speeds. High-frequency rotating-voltage injection with a single D-module bandpass vector filter and a phase-locked loop state observer with a new synchronization procedure are used to estimate the rotor position, which is needed only by the current model in stator flux observer at low speeds. A new rotor speed estimator for the whole speed-loop range, based on the stator flux speed estimation with a new dynamic correction depending on estimated torque, is proposed and tested. Extensive simulation results and significant experimental results provided good performance for the proposed IPMSM sensorless system in more than 1:1000 speed range, under full-load operation, from very low speeds (1 r/min experimental) up to rated speed.

[1]  S. Sul,et al.  Sensorless drive of surface-mounted permanent-magnet motor by high-frequency signal injection based on magnetic saliency , 2003 .

[2]  F. Blaabjerg,et al.  DTFC-SVM motion-sensorless control of a PM-assisted reluctance synchronous machine as starter-alternator for hybrid electric vehicles , 2006, IEEE Transactions on Power Electronics.

[3]  R. Lorenz,et al.  A physically insightful approach to the design and accuracy assessment of flux observers for field oriented induction machine drives , 1992 .

[4]  M. Schroedl,et al.  Position-sensorless biaxial position control with industrial PM motor drives based on INFORM- and back EMF model , 2002, IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02.

[5]  J. Holtz,et al.  Initial Rotor Polarity Detection and Sensorless Control of PM Synchronous Machines , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[6]  Robert D. Lorenz,et al.  Using multiple saliencies for the estimation of flux, position, and velocity in AC machines , 1997 .

[7]  Alfio Consoli,et al.  Industry application of zero-speed sensorless control techniques for PM synchronous motors , 2001 .

[8]  Oskar Wallmark,et al.  An improved speed and position estimator for salient permanent-magnet synchronous motors , 2005, IEEE Transactions on Industrial Electronics.

[9]  Ralph Kennel,et al.  Sensorless speed and position control of synchronous machines using alternating carrier injection , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..

[10]  A. Piippo,et al.  Adaptive observer combined with HF signal injection for sensorless control of PMSM drives , 2005, IEEE International Conference on Electric Machines and Drives, 2005..

[11]  J. Holtz,et al.  Sensorless vector control of induction motors at very low speed using a nonlinear inverter model and parameter identification , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[12]  Jung-Ik Ha,et al.  Analysis of permanent magnet machine for sensorless control based on high frequency signal injection , 2003 .

[13]  F. Blaabjerg,et al.  A modified direct torque control (DTC) for induction motor sensorless drive , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[14]  Silverio Bolognani,et al.  Extended Kalman filter tuning in sensorless PMSM drives , 2003 .

[15]  Mark Sumner,et al.  Hybrid rotor position observer for wide speed-range sensorless PM motor drives including zero speed , 2006, IEEE Transactions on Industrial Electronics.

[16]  Thomas M. Jahns,et al.  A novel method for initial rotor position estimation for IPM synchronous machine drives , 2003 .

[17]  F. Briz,et al.  Comparison of saliency-based sensorless control techniques for AC machines , 2004, IEEE Transactions on Industry Applications.

[18]  S. Shinnaka A new characteristics-varying two-input/output filter in D-module-designs, realizations and equivalence , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[19]  S. Shinnaka New "mirror-phase vector control" for sensorless drive of permanent-magnet synchronous motor with pole saliency , 2004, IEEE Transactions on Industry Applications.

[20]  Joachim Holtz,et al.  Sensorless Control of Induction Machines - With or Without Signal Injection? , 2006, IEEE Trans. Ind. Electron..

[21]  Seung-Ki Sul,et al.  Initial rotor position estimation of an interior permanent magnet synchronous machine using carrier-frequency injection methods , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..