Conjugated polyelectrolyte-based real-time fluorescence assay for alkaline phosphatase with pyrophosphate as substrate.
暂无分享,去创建一个
The fluorescence of the anionic, carboxylate-substituted poly(phenylene ethynylene) polymer PPECO2 is quenched very efficiently via the addition of 1 equiv of Cu(2+). Addition of pyrophosphate (PPi) into the weakly fluorescent solution of PPECO2 and Cu(2+) induces recovery of the polymer's fluorescence; the recovery occurs because PPi complexes with Cu(2+), effectively sequestering the ion so it cannot bind to the carboxylate groups of the polymer. A calibration curve was developed that relates the extent of fluorescence recovery to [PPi], making the PPECO2-Cu(2+) system a sensitive and selective turn-on sensor for PPi. Using the PPECO2-Cu(2+) system as the signal transducer, a real-time fluorescence turn-off assay for the enzyme alkaline phosphatase (ALP) using PPi as the substrate is developed. The assay operates with [PPi] in the micromolar range, and it offers a straightforward and rapid detection of ALP activity with the enzyme present in the nanomolar concentration range, operating either in an end point or real-time format. Kinetic and product inhibition parameters are derived by converting time-dependent fluorescence intensity into PPi (substrate) concentration, thus allowing calculation of the initial reaction rates (v(o)). Weak, nonspecific fluorescence responses are observed concomitant to addition of other proteins to the assay solution; however, the signal response to ALP is demonstrated to arise from the ALP catalyzed hydrolysis of PPi to phosphate (Pi).