Interlaboratory Evaluation of a Portable Fluorescence Method for the Measurement of Trace Beryllium in the Workplace

Researchers at Los Alamos National Laboratory (LANL) developed a field-portable fluorescence method for the measurement of trace beryllium in workplace samples such as surface dust and air filters. The technology has been privately licensed and is commercially available. In cooperation with the Analytical Subcommittee of the Beryllium Health and Safety Committee, we have carried out a collaborative interlaboratory evaluation of the LANL field-portable fluorescence method. The interlaboratory study was conducted for the purpose of providing performance data that can be used to support standard methods. Mixed cellulose ester (MCE) membrane filters and Whatman 541 filters were spiked with beryllium standard solutions so that the filters spanned the range ≈0.05 - ≈0.5 µg Be per sample. Sets of these filters were then coded (to ensure blind analysis) and sent to participating laboratories, where they were analyzed. Analysis consisted of the following steps: 1. Removal of the filters from transport cassettes and placement of them into 15-mL centrifuge tubes; 2. mechanically- assisted extraction of the filters in 5 mL of 1 % ammonium bifluoride solution (aqueous) for 30 min; 3.-4. filtration and transfer of sample extract aliquots (100 µL) into fluorescence cuvettes; 5. introduction of 1.9 mL of detection solution (to effect reaction of the fluorescence reagent with beryllium in the extracted sample); and 6. measurement of fluorescence at ≈475 nm using a portable fluorometer. This work presents performance data in support of a procedure that is targeted for publication as a National Institute for Occupational Safety and Health (NIOSH) method and as an ASTM International standard.

[1]  K Ashley,et al.  Ultrasonic extraction and portable anodic stripping voltammetric measurement of lead in paint, dust wipes, soil, and air: an interlaboratory evaluation. , 1999, Journal of environmental monitoring : JEM.

[2]  G. Schwedt,et al.  Off-line and on-line preconcentration of trace levels of beryllium using complexing agents with atomic spectrometric and fluorimetric detection , 1993 .

[3]  B. K. Pal,et al.  Chromotropic acid as fluorogenic reagent. I. Fluorimetric determination of beryllium , 1992 .

[4]  Joseph Wang,et al.  Trace measurements of beryllium by adsorptive stripping voltammetry and potentiometry , 1992 .

[5]  H. Hoshino,et al.  Selective determination of beryllium(II) ion at picomole per decimeter cubed levels by kinetic differentiation mode reversed-phase high-performance liquid chromatography with fluorometric detection using 2-(2'-hydroxyphenyl)-10-hydroxybenzo[H]quinoline as precolumn chelating reagent. , 2003, Analytical chemistry.

[6]  H. Hoshino,et al.  A novel fluorescence reagent, 10-hydroxybenzo[h]quinoline-7-sulfonate, for selective determination of beryllium(II) ion at pg cm(-3) levels. , 2001, The Analyst.

[7]  Ruiguang Song,et al.  Guidelines for air sampling and analytical method development and evaluation (May 1995). Technical report , 1994 .

[8]  P. C. Nascimento,et al.  Comparative studies of the determination of cyanide at low concentration levels in waste waters , 1993 .

[9]  R Barkman,et al.  ASTM. 1999. Standard practice for conducting an interlaboratory study to determine the precision of a test method. ASTM E691-92. In: Annual Book of ASTM Standards. Philadelphia, PA:American Society for Testing and Materials. , 2006 .

[10]  A. M. Díaz,et al.  Implementation of flow-through multi-sensors with bead injection spectroscopy: fluorimetric renewable surface biparameter sensor for determination of berillium and aluminum. , 2004, Talanta.