Wavelength-swept fiber laser based on acousto-optic tuning method

In this study, we have demonstrated a wavelength-swept fiber laser based on an acousto-optic tunable filter(AOTF) as a selective element and a semiconductor optical amplifier(SOA) as a gain medium in an internal fiber ring cavity. The light deriving from one port of the SOA goes through an optical isolator, the AOTF, a fiber coupler and a polarized controller successively, then it goes back to the other port of the SOA to form a ring cavity. The laser output is from another port of the fiber coupler. The laser made by this method is mainly used for swept-source optical coherence tomography(SS-OCT). The application of the SOA provides a sufficiently broad range and can ensure an increased axial resolution of SS-OCT. AOTF offers a wide tuning range, high switching speed and stable operation against vibration for the non-mechanical structure. The proposed wavelength-swept fiber laser ensures a high axial resolution of tomographic images and has a stable laser output. We have discussed the influence of the SOA injection current to the tuning range of the laser. In the SOA injection current of 280 mA, a continuous wavelength tuning range from 1295 to 1370 nm centered at a wavelength of 1330nm is obtained at the sweep rate of 1.06 kHz, and the power of the swept source was 1.14 mW. In addition, for quantitative characterization of the wavelength-swept performance with a AOTF, we have theoretically and experimentally analyzed the influence of the following controllable parameters: injection current, output power and sweeping frequency.

[1]  Teresa C. Chen,et al.  Spectral Domain Optical Coherence Tomography , 2006 .

[2]  A. A. Lobintsov,et al.  Semiconductor lasers with a continuous tuning range above 100 nm in the nearest IR spectral region , 2015 .

[3]  J. Schuman,et al.  Combining Information From 3 Anatomic Regions in the Diagnosis of Glaucoma With Time-Domain Optical Coherence Tomography , 2014, Journal of glaucoma.

[4]  U. Schmidt-Erfurth,et al.  High-Resolution Spectral Domain-Optical Coherence Tomography in Multiple Sclerosis, Part II – the Total Macular Volume. The First Follow-Up Study over 2 Years , 2014, Front. Neurol..

[5]  Danjie Li,et al.  Posterior precortical vitreous pockets and connecting channels in children on swept-source optical coherence tomography. , 2014, Investigative ophthalmology & visual science.

[6]  Reginald Birngruber,et al.  Imaging of photothermal tissue expansion via phase sensitive optical coherence tomography , 2012, Photonics West - Biomedical Optics.

[7]  S. Kishi,et al.  Posterior precortical vitreous pocket. , 1991, Archives of ophthalmology.

[8]  Beop-Min Kim,et al.  Line-Field Optical Coherence Tomography Using Frequency-Sweeping Source , 2008, IEEE Journal of Selected Topics in Quantum Electronics.

[9]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[10]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[11]  Martin F. Kraus,et al.  En face enhanced-depth swept-source optical coherence tomography features of chronic central serous chorioretinopathy. , 2014, Ophthalmology.