Realistic loads for testing hip implants.

The aim here was to define realistic load conditions for hip implants, based on in vivo contact force measurements, and to see whether current ISO standards indeed simulate real loads. The load scenarios obtained are based on in vivo hip contact forces measured in 4 patients during different activities and on activity records from 31 patients. The load scenarios can be adapted to various test purposes by applying average or high peak loads, high-impact activities or additional low-impact activities, and by simulating normal or very active patients. The most strenuous activities are walking (average peak forces 1800 N, high peak forces 3900 N), going up stairs (average peak forces 1900 N, high peak forces 4200 N) and stumbling (high peak forces 11,000 N). Torsional moments are 50% higher for going up stairs than for walking. Ten million loading cycles simulate an implantation time of 3.9 years in active patients. The in vitro fatigue properties of cementless implant fixations are exceeded during stumbling. At least for heavyweight and very active subjects, the real load conditions are more critical than those defined by the ISO standards for fatigue tests.

[1]  Wolfgang Plitz,et al.  A model for assessing the rotational stability of uncemented femoral implants , 2001, Archives of Orthopaedic and Trauma Surgery.

[2]  E. Schneider,et al.  Influence of muscle forces on femoral strain distribution. , 1998, Journal of biomechanics.

[3]  L A Whiteside,et al.  Rotational stability of noncemented total hip femoral components. , 1996, American journal of orthopedics.

[4]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[5]  P. Morberg,et al.  The influence of design parameters on cortical strain distribution of a cementless titanium femoral stem. , 2002, Medical engineering & physics.

[6]  M. Heller,et al.  Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro. , 2005, Journal of biomechanics.

[7]  S Blatcher,et al.  Influence of head constraint and muscle forces on the strain distribution within the intact femur. , 2000, Medical engineering & physics.

[8]  G. Bergmann,et al.  Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. , 2001, Clinical biomechanics.

[9]  A Rohlmann,et al.  Is staircase walking a risk for the fixation of hip implants? , 1995, Journal of biomechanics.

[10]  G. Bergmann,et al.  Musculo-skeletal loading conditions at the hip during walking and stair climbing. , 2001, Journal of biomechanics.

[11]  G. Bergmann,et al.  Hip joint contact forces during stumbling , 2004, Langenbeck's Archives of Surgery.

[12]  G Bergmann,et al.  Determination of muscle loading at the hip joint for use in pre-clinical testing. , 2005, Journal of biomechanics.

[13]  J. P. Paul,et al.  Strength requirements for internal and external prostheses. , 1999, Journal of biomechanics.

[14]  M Honl,et al.  Duration and frequency of every day activities in total hip patients. , 2001, Journal of biomechanics.

[15]  Michael J. Voor,et al.  Femoral component revision using impacted morsellised cancellous graft , 1996 .

[16]  R. Huiskes,et al.  Stair Climbing is More Detrimental to the Cement in Hip Replacement than Walking , 2002, Clinical orthopaedics and related research.

[17]  P J Prendergast,et al.  Mechanical simulation of muscle loading on the proximal femur: analysis of cemented femoral component migration with and without muscle loading. , 2003, Clinical biomechanics.

[18]  R. Huiskes,et al.  Hip-joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. , 2001, Journal of biomechanics.

[19]  A Rohlmann,et al.  Hip endoprosthesis for in vivo measurement of joint force and temperature. , 1999, Journal of biomechanics.

[20]  T W Phillips,et al.  Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal. , 1991, Journal of biomechanics.

[21]  A. Amis,et al.  The effect of muscle loading on the simulation of bone remodelling in the proximal femur. , 2005, Journal of biomechanics.

[22]  N. Gathercole,et al.  Fatigue testing of a proximal femoral hip component , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  H. Tullos,et al.  Distal stem design and the torsional stability of cementless femoral stems. , 1995, The Journal of arthroplasty.

[24]  G Bergmann,et al.  Averaging of strongly varying signals. , 2001, Biomedizinische Technik. Biomedical engineering.