An alternate formulation of blood vessel mechanics and the meaning of the in vivo property.

In an effort to bridge the gap between theoretically based vascular mechanics and simpler, clinically relevant compliance models, an alternative complementary energy formulation as well as an improved experimental method are proposed. This formulation generalizes the uniaxial compliance models to multiaxial stretch and twist and clarifies the role of the total in vivo force (measured in biaxial vascular testing) in vessel stability. The measurement of wall thickness when incompressibility is assumed, and the assumption of the existence of an unloaded state are unnecessary. Scattered results from both clinical and mechanical literature are reinterpreted in view of this new understanding of vascular mechanics. Canine saphenous veins (4-5 mm in diameter) conform to the behavior expected from the analysis. Their in vivo property is shown to be a passive property, independent of smooth muscle tone. Redundant particle tracking, control of force and pressure values and the use of papaverine, result, respectively, in strain measurements accurate to within 0.002, experimental control accurate to 0.5% of full range, and repeatable experiments over a few days. The validated system and the new formulation show great potential for exploiting the benefits of innovative experimental design and statistically reliable data analysis.

[1]  R. Shield,et al.  The stability of a finitely inflated cylindrical elastic membrane under axial compression , 1975 .

[2]  J D Humphrey,et al.  Quantification of strains in biaxially tested soft tissues. , 1987, Journal of biomechanics.

[3]  Y. Fung,et al.  Biomechanics: Mechanical Properties of Living Tissues , 1981 .

[4]  R P Vito,et al.  Two-dimensional stress-strain relationship for canine pericardium. , 1990, Journal of biomechanical engineering.

[5]  P. Dobrin,et al.  Biaxial anisotropy of dog carotid artery: estimation of circumferential elastic modulus. , 1986, Journal of biomechanics.

[6]  L J Brossollet,et al.  The effects of cryopreservation on the biaxial mechanical properties of canine saphenous veins. , 1997, Journal of biomechanical engineering.

[7]  R. T. Shield,et al.  The stability of a cylindrical elastic membrane of biological tissue and the effect of internal fluid flow , 1980 .

[8]  L J Brossollet,et al.  A new approach to mechanical testing and modeling of biological tissues, with application to blood vessels. , 1996, Journal of biomechanical engineering.

[9]  R. Bauer,et al.  Mechanical properties of arteries. , 1982, Biorheology.

[10]  G L'Italien,et al.  Effect of compliance mismatch on vascular graft patency. , 1987, Journal of vascular surgery.

[11]  H. W. Weizsäcker,et al.  Analysis of the passive mechanical properties of rat carotid arteries. , 1983, Journal of biomechanics.

[12]  P. Dobrin,et al.  Vascular Smooth Muscle and the Anisotropy of Dog Carotid Artery , 1970, Circulation research.

[13]  F. Yin,et al.  Augmentation of regional coronary blood flow by intra-aortic balloon counterpulsation in patients with unstable angina. , 1983, Circulation.

[14]  W. Quist,et al.  Integrity of vein grafts as a function of initial intimal and medial preservation. , 1983, Circulation.

[15]  P. Dobrin,et al.  Elastase, collagenase, and the biaxial elastic properties of dog carotid artery. , 1984, The American journal of physiology.

[16]  I. S. Sokolnikoff Mathematical theory of elasticity , 1946 .

[17]  B. Purinya,et al.  Determination of the shear modulus of human blood-vessel walls , 1978 .

[18]  Y. Fung,et al.  Pseudoelasticity of arteries and the choice of its mathematical expression. , 1979, The American journal of physiology.

[19]  On the stability of finitely deformed elastic membranes , 1972 .

[20]  Tensile stability of cylindrical membranes , 1983 .

[21]  W. Quist,et al.  An improved technique for preservation of endothelial morphology in vein grafts. , 1981, Surgery.

[22]  E. G. Tickner,et al.  A theory for the static elastic behavior of blood vessels. , 1967, Biorheology.

[23]  L. J. Brossollet Mechanical Issues in Vascular Grafting: A Review , 1992, The International journal of artificial organs.

[24]  W. Flügge Stresses in Shells , 1960 .

[25]  D. J. Patel,et al.  The Elastic Symmetry of Arterial Segments in Dogs , 1969, Circulation research.

[26]  E. Bradley,et al.  Length-force and volume-pressure relationships of arteries. , 1977 .

[27]  J. Humphrey,et al.  A theoretically-based experimental approach for identifying vascular constitutive relations. , 1989, Biorheology.

[28]  A. Love A treatise on the mathematical theory of elasticity , 1892 .

[29]  H. W. Weizsäcker,et al.  Isotropy and anisotropy of the arterial wall. , 1988, Journal of biomechanics.

[30]  R. Shield On the stability of finitely deformed elastic membranes , 1971 .

[31]  W. Abbott,et al.  Increased compliance near vascular anastomoses. , 1985, Journal of vascular surgery.

[32]  M Hasegawa Rheological properties and wall structures of large veins. , 1983, Biorheology.