Online monitoring of the two-dimensional temperature field in a boiler furnace based on acoustic computed tomography

Abstract Online monitoring of the temperature field is crucial to optimally adjust combustion within a boiler. In this paper, acoustic computed tomography (CT) technology was used to obtain the temperature profile of a furnace cross-section. The physical principles behind acoustic CT, acoustic signals and time delay estimation were studied. Then, the technique was applied to a domestic 600-MW coal-fired boiler. Acoustic CT technology was used to monitor the temperature field of the cross-section in the boiler furnace, and the temperature profile was reconstructed through ART iteration. The linear sweeping frequency signal was adopted as the sound source signal, whose sweeping frequency ranged from 500 to 3000 Hz with a sweeping cycle of 0.1 s. The generalized cross-correlation techniques with PHAT and ML were used as the time delay estimation method when the boiler was in different states. Its actual operation indicated that the monitored images accurately represented the combustion state of the boiler, and the acoustic CT system was determined to be accurate and reliable.

[1]  Kim Dam-Johansen,et al.  The effect of combustion conditions in a full-scale low-NOx coal fired unit on fly ash properties for its application in concrete mixtures , 2009 .

[2]  Jiuping Xu,et al.  Greenhouse Gas Control , 2014 .

[3]  M. Doubenskaia,et al.  Pyrometry in laser surface treatment , 2006 .

[4]  Yong Yan,et al.  Investigations into the ignition behaviors of pulverized coals and coal blends in a drop tube furnace using flame monitoring techniques , 2010 .

[5]  Koichi Mizutani,et al.  Fast Method for Visualization of Temperature Distribution Using Acoustic Computerized Tomography : Instrumentation, Measurement, and Fabrication Technology , 2001 .

[6]  Wei Fan,et al.  Experimental study on underwater acoustic imaging of 2-D temperature distribution around hot springs on floor of Lake Qiezishan, China , 2010 .

[7]  D. Wagner,et al.  Some aspects of Portevin–Le Chatelier plastic instabilities investigated by infrared pyrometry , 2005 .

[8]  Ange Nzihou,et al.  Physicochemical properties and heavy metals leachability of fly ash from coal-fired power plant , 2012 .

[9]  Shuhei Takahashi,et al.  Acoustic computer tomographic pyrometry for two-dimensional measurement of gases taking into account the effect of refraction of sound wave paths , 2000 .

[10]  Yong Yan,et al.  Monitoring and characterisation of pulverised coal flames using digital imaging techniques , 2002 .

[11]  Amornvadee Veawab,et al.  Environmental impacts of absorption-based CO2 capture unit for post-combustion treatment of flue gas from coal-fired power plant , 2007 .

[12]  E. Salerno,et al.  An acoustic pyrometer system for tomographic thermal imaging in power plant boilers , 1996 .

[13]  C. Jen,et al.  Experimental evaluation of clad metallic buffer rods for high temperature ultrasonic measurements , 2000 .

[14]  David Popp,et al.  Exploring Links Between Innovation and Diffusion: Adoption of NOX Control Technologies at US Coal-fired Power Plants , 2010 .

[15]  C. Nielsen,et al.  Establishment of a database of emission factors for atmospheric pollutants from Chinese coal-fired power plants , 2010 .

[16]  Yongping Yang,et al.  Data Mining-Based Operation Optimization of Large Coal-Fired Power Plants , 2012 .

[17]  Fabrice Mériaudeau,et al.  Real time multispectral high temperature measurement: Application to control in the industry , 2007, Image Vis. Comput..

[18]  A. Tarantola Inverse problem theory : methods for data fitting and model parameter estimation , 1987 .

[19]  Ho Young Park,et al.  Numerical and experimental investigations on the gas temperature deviation in a large scale, advanced low NOx, tangentially fired pulverized coal boiler , 2013 .

[20]  William M D Wright,et al.  Simultaneous reconstruction of flow and temperature cross-sections in gases using acoustic tomography. , 2003, The Journal of the Acoustical Society of America.

[21]  K. J. Young,et al.  On the systematic error associated with the measurement of temperature using acoustic pyrometry in combustion products of unknown mixture , 1998 .

[22]  Paul Feron,et al.  Exploring the potential for improvement of the energy performance of coal fired power plants with post-combustion capture of carbon dioxide , 2010 .

[23]  B. S. Hoyle,et al.  Ultrasound in the process industries , 1994 .

[24]  Javier Ballester,et al.  Diagnostic techniques for the monitoring and control of practical flames , 2010 .

[25]  Junghui Chen,et al.  Monitoring combustion systems using HMM probabilistic reasoning in dynamic flame images , 2010 .

[26]  Qiong Li,et al.  On-line monitoring the performance of coal-fired power unit: A method based on support vector machine , 2009 .

[27]  Roland Müller,et al.  Acoustic tomography on the basis of travel-time measurement , 2004 .

[28]  Xianchang Li,et al.  Spectrometer-based combustion monitoring for flame stoichiometry and temperature control , 2005 .

[29]  R. Keys Cubic convolution interpolation for digital image processing , 1981 .