Understanding dynamic model validation of a wind turbine generator and a wind power plant

Regional reliability organizations require power plants to validate the dynamic models that represent them to ensure that power systems studies are performed to the best representation of the components installed. In the process of validating a wind power plant (WPP), one must be cognizant of the parameter settings of the wind turbine generators (WTGs) and the operational settings of the WPP. Validating the dynamic model of a WPP is required to be performed periodically. This is because the control parameters of the WTGs and the other supporting components within a WPP may be modified to comply with new grid codes or upgrades to the WTG controller with new capabilities developed by the turbine manufacturers or requested by the plant owners or operators. The diversity within a WPP affects the way we represent it in a model. Diversity within a WPP may be found in the way the WTGs are controlled, the wind resource, the layout of the WPP (electrical diversity), and the type of WTGs used. Each group of WTGs constitutes a significant portion of the output power of the WPP, and their unique and salient behaviors should be represented individually. The objective of this paper is to illustrate the process of dynamic model validations of WTGs and WPPs, the available data recorded that must be screened before it is used for the dynamic validations, and the assumptions made in the dynamic models of the WTG and WPP that must be understood. Without understanding the correct process, the validations may lead to the wrong representations of the WTG and WPP modeled.

[1]  E. Muljadi,et al.  Equivalencing the collector system of a large wind power plant , 2006, 2006 IEEE Power Engineering Society General Meeting.

[2]  E. Muljadi,et al.  FAULT analysis at a wind power plant for one year of observation , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[3]  E. Muljadi,et al.  Method of equivalencing for a large wind power plant with multiple turbine representation , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[4]  Mohit Singh,et al.  Wind Power Plant Model Validation Using Synchrophasor Measurements at the Point of Interconnection , 2015, IEEE Transactions on Sustainable Energy.

[5]  Richard Gagnon,et al.  Generic Equivalent Collector System Parameters for Large Wind Power Plants , 2011, IEEE Transactions on Energy Conversion.