A fire test on continuous reinforced concrete slabs in a full-scale multi-story steel-framed building

Abstract To further understand the fire behavior of concrete floor slabs, this paper examines the results of a fire test on continuous concrete floor slabs in a full-scale three-story steel-framed building. The case under experimental study models the reality of fire conditions more closely than previous tests and involves the construction of a special furnace on the building's second floor to heat four panels (two by two) and steel beams on the third floor. The experimental results are investigated in detail and consider the furnace temperature, temperature distribution, vertical and horizontal deflections, and failure patterns of the structural elements during the heating and cooling phases. The testing data indicate that the number and locations of the heated panels in the floor also have a considerable effect on the continuous concrete floor's fire behavior, apart from the boundary constraint conditions provided by the adjacent structural members. In addition, the steel beams exhibit better fire-resistant performance than that observed in standard fire tests depending on their structural integrity and the interaction between structural members. In contrast to its high-strength bolt connections, the building's welded-bolted connections do not cause local buckling of the steel beams subjected to fire.

[1]  Asif Usmani,et al.  A structural analysis of the first Cardington test , 2001 .

[2]  Asif Usmani,et al.  A structural analysis of the Cardington British Steel corner test , 2002 .

[3]  Ian Burgess,et al.  Computer simulation of a full-scale structural fire test , 1996 .

[4]  Colin Bailey,et al.  The behaviour of full-scale steel-framed buildings subjected to compartment fires , 1999 .

[5]  Y.-L. Dong,et al.  Determination of tensile membrane effects by segment equilibrium , 2010 .

[6]  Ian Burgess,et al.  Modeling Membrane Action of Concrete Slabs in Composite Buildings in Fire. II: Validations , 2003 .

[7]  Yong Wang,et al.  Nonlinear numerical modeling of two-way reinforced concrete slabs subjected to fire , 2013 .

[8]  A. Y. Elghazouli,et al.  Failure of unrestrained lightly reinforced concrete slabs under fire, Part II: Verification and application , 2010 .

[9]  Colin Bailey,et al.  Small-scale concrete slab tests at ambient and elevated temperatures , 2007 .

[10]  A. Y. Elghazouli,et al.  Failure of unrestrained lightly reinforced concrete slabs under fire, Part I: Analytical models , 2010 .

[11]  Linus Lim,et al.  Experimental fire tests of two-way concrete slabs , 1992 .

[12]  Ian Burgess,et al.  Nonlinear Analysis of Reinforced Concrete Slabs Subjected to Fire , 1999 .

[13]  Roger J. Plank,et al.  Thermal and structural behaviour of a full-scale composite building subject to a severe compartment fire , 2007 .

[14]  Jean-Marc Franssen,et al.  Numerical modelling of two-way reinforced concrete slabs in fire , 2004 .

[15]  R. G. Burg,et al.  Fire test of concrete slab reinforced with epoxy-coated bars , 1989 .

[16]  Ian Burgess,et al.  Modeling Membrane Action of Concrete Slabs in Composite Buildings in Fire. I: Theoretical Development , 2003 .

[17]  Monther B. Dwaikat,et al.  A numerical model for predicting the fire resistance of reinforced concrete beams , 2008 .

[18]  Aldina Santiago,et al.  Experimental behaviour of a steel structure under natural fire , 2006 .

[19]  Y.-L. Dong Tensile membrane effects of concrete slabs in fire , 2010 .

[20]  Kuldeep R. Prasad,et al.  Thermal and structural response of two-storey two-bay composite steel frames under furnace loading , 2009 .

[21]  Y.-L. Dong,et al.  Fire tests on two-way concrete slabs in a full-scale multi-storey steel-framed building , 2013 .

[22]  Yuli Dong,et al.  Experimental Study on the Behavior of Full-Scale Composite Steel Frames under Furnace Loading , 2008 .

[23]  Colin Bailey,et al.  Behaviour of concrete floor slabs at ambient and elevated temperatures , 2007 .

[24]  M. A O'Connor,et al.  Behaviour of a Multi-storey Steel Framed Building Subjected to Fire Attack , 1998 .