Intrapartum computerized fetal heart rate parameters and metabolic acidosis at birth.

OBJECTIVE To estimate to what extent computerized fetal heart rate (FHR) parameters are affected by labor and to estimate the relationship between FHR parameters and the degree of fetal metabolic acidosis in laboring patients at term. METHODS Fifty-one women between 37 and 42 weeks' gestational age were recruited prospectively in the following groups: 1) nonlaboring women, and 2) laboring women requiring fetal scalp electrode for continuous electronic FHR monitoring. Computerized FHR analysis was performed for 1 hour within 6 hours of delivery in the nonlaboring group and continuously throughout labor in the laboring group. Multiple linear regression analysis was used to determine the relationship between individual FHR parameters during the last hour before delivery and the degree of metabolic acidosis at birth. RESULTS The umbilical cord artery base excess and pH did not show any significant correlation with any of the computer-derived FHR parameters studied. Both umbilical cord venous base excess and pH were inversely related to the number of large FHR decelerations (r = -.46, P <.01 and r = -.56, P <.01, respectively). Labor was associated with a 31% increase in both short- and long-term FHR variation in the reassuring FHR tracing group when compared with nonlaboring women. Although this increase in FHR variation was not seen in the nonreassuring FHR tracing group, there was no relationship to the degree of metabolic acidosis at birth. CONCLUSION In term pregnant women with reassuring FHR tracing, labor causes an increase in both short- and long-term FHR variation, which was abolished in the presence of nonreassuring FHR tracing. Computer-derived FHR parameters studied during the last hour of labor were not correlated with the degree of metabolic acidosis as measured in the umbilical artery at birth.

[1]  G. S. Dawes,et al.  Characterization of the reduced heart rate variation in growth‐retarded fetuses , 1984 .

[2]  R. Gagnon,et al.  Fetal heart rate patterns in growth-restricted fetal sheep induced by chronic fetal placental embolization. , 1997, American journal of obstetrics and gynecology.

[3]  A. Hellegers,et al.  Nomograms and empirical equations relating oxygen tension, percentage saturation, and pH in maternal and fetal blood. , 1961, American journal of obstetrics and gynecology.

[4]  R. Gagnon,et al.  Fetal heart rate patterns in the small-for-gestational-age human fetus. , 1989, American journal of obstetrics and gynecology.

[5]  R. Gagnon,et al.  A comparison between visual and computer analysis of antepartum fetal heart rate tracings. , 1993, American journal of obstetrics and gynecology.

[6]  G. Dawes,et al.  Computerized analysis of episodic changes in fetal heart rate variation in early labor. , 1991, American journal of obstetrics and gynecology.

[7]  J. Low,et al.  The relationship between antepartum fetal heart rate, intrapartum fetal heart rate, and fetal acid-base status , 1986 .

[8]  J. Low,et al.  The effect of maternal, labor, and fetal factors upon fetal heart rate during the intrapartum period. , 1981, American journal of obstetrics and gynecology.

[9]  H W Jongsma,et al.  Intrapartum fetal pulse oximetry: fetal oxygen saturation trends during labor and relation to delivery outcome. , 1994, American journal of obstetrics and gynecology.

[10]  B. Richardson,et al.  Nuchal cord evident at birth impacts on fetal size relative to that of the placenta. , 1997, Early human development.

[11]  D. Muir,et al.  The relationship between perinatal hypoxia and newborn encephalopathy. , 1985, American journal of obstetrics and gynecology.

[12]  J. Waller,et al.  A comparison of visual analyses of intrapartum fetal heart rate tracings according to the new national institute of child health and human development guidelines with computer analyses by an automated fetal heart rate monitoring system. , 2000, American journal of obstetrics and gynecology.

[13]  G S Dawes,et al.  Computerized Fetal Heart Rate Analysis in Labor , 1991, Obstetrics and gynecology.

[14]  G. Dawes,et al.  Analysis of fetal heart rate on‐line at 32 weeks gestation , 1984, British journal of obstetrics and gynaecology.

[15]  G S Dawes,et al.  System 8000: Computerized antenatal FHR analysis , 1991, Journal of perinatal medicine.

[16]  K. Greene,et al.  ELECTRONIC FETAL HEART RATE MONITORING : RESEARCH GUIDELINES FOR INTERPRETATION. AUTHOR'S REPLY , 1997 .

[17]  A. Rudolph,et al.  Heart rate and blood pressure responses to umbilical cord compression in fetal lambs with special reference to the mechanism of variable deceleration. , 1983, American journal of obstetrics and gynecology.

[18]  T. Weber The influence of cord complications on fetal pH, neonatal APGAR score, and the acid base state and oxygenation of the umbilical artery and vein , 1981, Journal of perinatal medicine.

[19]  J. Padbury,et al.  Fetal endocrine and renal responses to in utero ventilation and umbilical cord occlusion. , 1993, American journal of obstetrics and gynecology.

[20]  D Maulik,et al.  Computerized analysis of fetal heart rate variation in postterm pregnancy: prediction of intrapartum fetal distress and fetal acidosis. , 1994, American journal of obstetrics and gynecology.

[21]  B. Richardson,et al.  Fetal cerebral, circulatory, and metabolic responses during heart rate decelerations with umbilical cord compression. , 1996, American journal of obstetrics and gynecology.

[22]  J. Challier,et al.  Transfer of ritodrine and norepinephrine in human placenta: in vitro study. , 1982, Developmental pharmacology and therapeutics.

[23]  A. Vintzileos,et al.  The Efficacy of Individual Computer Heart Rate Indices in Detecting Acidemia at Birth in Growth‐Restricted Fetuses , 1996, Obstetrics and gynecology.