Deep ultrasound denoising without clean data

On one hand, the transmitted ultrasound beam gets attenuated as propagates through the tissue. On the other hand, the received Radio-Frequency (RF) data contains an additive Gaussian noise which is brought about by the acquisition card and the sensor noise. These two factors lead to a decreasing Signal to Noise Ratio (SNR) in the RF data with depth, effectively rendering deep regions of B-Mode images highly unreliable. There are three common approaches to mitigate this problem. First, increasing the power of transmitted beam which is limited by safety threshold. Averaging consecutive frames is the second option which not only reduces the framerate but also is not applicable for moving targets. And third, reducing the transmission frequency, which deteriorates spatial resolution. Many deep denoising techniques have been developed, but they often require clean data for training the model, which is usually only available in simulated images. Herein, a deep noise reduction approach is proposed which does not need clean training target. The model is constructed between noisy input-output pairs, and the training process interestingly converges to the clean image that is the average of noisy pairs. Experimental results on real phantom as well as ex vivo data confirm the efficacy of the proposed method for noise cancellation.

[1]  P. Alam,et al.  H , 1887, High Explosives, Propellants, Pyrotechnics.

[2]  Florian Jug,et al.  Noise2Void - Learning Denoising From Single Noisy Images , 2018, 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR).

[3]  Hassan Rivaz,et al.  Analytic Global Regularized Backscatter Quantitative Ultrasound , 2020, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  R. F. Wagner,et al.  Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[5]  R. Cobbold Foundations of Biomedical Ultrasound , 2006 .

[6]  Sudhish N. George,et al.  A review on medical image denoising algorithms , 2020, Biomed. Signal Process. Control..

[7]  Thomas Brox,et al.  U-Net: Convolutional Networks for Biomedical Image Segmentation , 2015, MICCAI.

[8]  P. Alam ‘W’ , 2021, Composites Engineering.

[9]  W. Zuo,et al.  Deep Learning on Image Denoising: An overview , 2019, Neural Networks.

[10]  Jaakko Lehtinen,et al.  Noise2Noise: Learning Image Restoration without Clean Data , 2018, ICML.

[11]  Pierrick Coupé,et al.  Nonlocal Means-Based Speckle Filtering for Ultrasound Images , 2009, IEEE Transactions on Image Processing.

[12]  Loïc Royer,et al.  Noise2Self: Blind Denoising by Self-Supervision , 2019, ICML.