Strategies to extend the lifetime of bioelectrochemical enzyme electrodes for biosensing and biofuel cell applications

Enzymes are powerful catalysts for biosensor and biofuel cell electrodes due to their unique substrate specificity. This specificity is defined by the amino acid chain's complex three-dimensional structure based on non-covalent forces, being also responsible for the very limited enzyme lifetime of days to weeks. Many electrochemical applications, however, would benefit from lifetimes over months to years. This mini-review provides a critical overview of strategies and ideas dealing with the problem of short enzyme lifetime, which limits the overall lifetime of bioelectrochemical electrodes. The most common approaches aim to stabilize the enzyme itself. Various immobilization techniques have been used to reduce flexibility of the amino acid chain by introducing covalent or non-covalent binding forces to external molecules. The enzyme can also be stabilized using genetic engineering methods to increase the binding forces within the protein or by optimizing the environment in order to reduce destabilizing interactions. In contrast, renewing the inactivated catalyst decouples overall system lifetime from the limited enzyme lifetime and thereby promises theoretically unlimited electrode lifetimes. Active catalyst can be supplied by exchanging the electrolyte repeatedly. Alternatively, integrated microorganisms can display the enzymes on their surface or secrete them to the electrolyte, allowing unattended power supply for long-term applications.

[1]  R. Zengerle,et al.  Carbon electrodes for direct electron transfer type laccase cathodes investigated by current density-cathode potential behavior. , 2010, Biosensors & bioelectronics.

[2]  H. Kaji,et al.  MINIATURED BIOFUEL CELLS AUTOMATICALLY RELAYED FOR LONGER-TERM POWER GENERATION , 2009 .

[3]  P. Atanasov,et al.  Performance of glucose biosensor based on oxygen electrode in physiological fluids and at body temperature , 1996 .

[4]  Shelley D. Minteer,et al.  Extended Lifetime Biofuel Cells , 2008 .

[5]  K. Sode,et al.  Stabilization of quaternary structure of water-soluble quinoprotein glucose dehydrogenase , 2003, Molecular biotechnology.

[6]  Koji Sode,et al.  Development of a novel glucose enzyme fuel cell system employing protein engineered PQQ glucose dehydrogenase. , 2005, Biosensors & bioelectronics.

[7]  Lital Alfonta,et al.  Surface display of redox enzymes in microbial fuel cells. , 2009, Journal of the American Chemical Society.

[8]  Bao-Lian Su,et al.  Immobilization technology: a sustainable solution for biofuel cell design , 2012 .

[9]  Gerd Wohlfahrt,et al.  Aspects of the mechanism of catalysis of glucose oxidase: A docking, molecular mechanics and quantum chemical study , 1998, J. Comput. Aided Mol. Des..

[10]  T. Taniyama,et al.  Secretory and continuous expression of Aspergillus niger glucose oxidase gene in Pichia pastoris. , 2007, Protein expression and purification.

[11]  H. Yoshida,et al.  Construction of Engineered Water-soluble PQQ Glucose Dehydrogenase with Improved Substrate Specificity , 2002 .

[12]  Koji Sode,et al.  PQQ glucose dehydrogenase with novel electron transfer ability. , 2004, Biochemical and biophysical research communications.

[13]  Bor Yann Liaw,et al.  Enzyme-based biofuel cells. , 2007, Current opinion in biotechnology.

[14]  Qing Zhang,et al.  The Molecular Biology Toolkit (MBT): a modular platform for developing molecular visualization applications , 2005, BMC Bioinformatics.

[15]  S. Cosnier Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. , 1999, Biosensors & bioelectronics.

[16]  P Atanasov,et al.  Implantation of a refillable glucose monitoring-telemetry device. , 1997, Biosensors & bioelectronics.

[17]  E. Katchalski‐Katzir,et al.  Immobilized enzymes--learning from past successes and failures. , 1993, Trends in biotechnology.

[18]  Michael J. Hageman,et al.  THE ROLE OF MOISTURE IN PROTEIN STABILITY , 1988 .

[19]  P Atanasov,et al.  Biosensor for continuos glucose monitoring. , 1994, Biotechnology and bioengineering.

[20]  Fwu-Shan Sheu,et al.  Electrochemical Biosensing Platforms Using Phthalocyanine-Functionalized Carbon Nanotube Electrode , 2005 .

[21]  Anthony Turner,et al.  Mediated Biocatalytic Electrodes and Enzyme Stabilisation for Power Generation , 2010 .

[22]  E Wilkins,et al.  Rechargeable glucose electrodes for long-term implantation. , 1991, Journal of biomedical engineering.

[23]  P Atanasov,et al.  Short-term canine implantation of a glucose monitoring-telemetry device. , 1996, Medical engineering & physics.

[24]  A. Klibanov,et al.  Protein stability in controlled-release systems , 2000, Nature Biotechnology.

[25]  Güray Güven,et al.  Protein Engineering – An Option for Enzymatic Biofuel Cell Design , 2010 .

[26]  R. Borchardt,et al.  Stability of Protein Pharmaceuticals , 1989, Pharmaceutical Research.

[27]  Ulrich Schwaneberg,et al.  Making glucose oxidase fit for biofuel cell applications by directed protein evolution. , 2006, Biosensors & bioelectronics.

[28]  P Atanasov,et al.  Integrated implantable device for long-term glucose monitoring. , 1995, Biosensors & bioelectronics.

[29]  Vojtech Svoboda,et al.  Enzyme catalysed biofuel cells , 2008 .

[30]  Adam Heller,et al.  Sources of instability of ‘wired’ enzyme anodes in serum: urate and transition metal ions , 2001 .

[31]  Donald Voet,et al.  Fundamentals of Biochemistry , 1999 .

[32]  D Schomburg,et al.  1.8 and 1.9 A resolution structures of the Penicillium amagasakiense and Aspergillus niger glucose oxidases as a basis for modelling substrate complexes. , 1999, Acta crystallographica. Section D, Biological crystallography.

[33]  Mathieu Etienne,et al.  Multiscale-tailored bioelectrode surfaces for optimized catalytic conversion efficiency. , 2011, Langmuir : the ACS journal of surfaces and colloids.

[34]  Scott Calabrese Barton,et al.  Enzymatic biofuel cells for implantable and micro-scale devices , 2004 .