Qualitative and Quantitative Evaluation of Six Algorithms for Correcting Intensity Nonuniformity Effects

The desire to correct intensity nonuniformity in magnetic resonance images has led to the proliferation of nonuniformity-correction (NUC) algorithms with different theoretical underpinnings. In order to provide end users with a rational basis for selecting a given algorithm for a specific neuroscientific application, we evaluated the performance of six NUC algorithms. We used simulated and real MRI data volumes, including six repeat scans of the same subject, in order to rank the accuracy, precision, and stability of the nonuniformity corrections. We also compared algorithms using data volumes from different subjects and different (1.5T and 3.0T) MRI scanners in order to relate differences in algorithmic performance to intersubject variability and/or differences in scanner performance. In phantom studies, the correlation of the extracted with the applied nonuniformity was highest in the transaxial (left-to-right) direction and lowest in the axial (top-to-bottom) direction. Two of the six algorithms demonstrated a high degree of stability, as measured by the iterative application of the algorithm to its corrected output. While none of the algorithms performed ideally under all circumstances, locally adaptive methods generally outperformed nonadaptive methods.

[1]  M S Cohen,et al.  Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging , 2000, Human brain mapping.

[2]  Alan C. Evans,et al.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data , 1998, IEEE Transactions on Medical Imaging.

[3]  R P Velthuizen,et al.  Review and evaluation of MRI nonuniformity corrections for brain tumor response measurements. , 1998, Medical physics.

[4]  Anders M. Dale,et al.  Cortical Surface-Based Analysis I. Segmentation and Surface Reconstruction , 1999, NeuroImage.

[5]  Richard A. Robb,et al.  Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction , 1998, IEEE Transactions on Medical Imaging.

[6]  David A. Rottenberg,et al.  Methods for evaluating the performance of MRI nonuniformity correction algorithms , 1999 .

[7]  John Ashburner,et al.  MRI Sensitivity Correction and Tissue Classification , 1998, NeuroImage.

[8]  R. Leahy,et al.  Magnetic Resonance Image Tissue Classification Using a Partial Volume Model , 2001, NeuroImage.

[9]  D. Louis Collins,et al.  Design and construction of a realistic digital brain phantom , 1998, IEEE Transactions on Medical Imaging.

[10]  S. Arridge,et al.  Sources of intensity nonuniformity in spin echo images at 1.5 T , 1994, Magnetic resonance in medicine.

[11]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[12]  D. Teichberg,et al.  Local histogram correction of MRI spatially dependent image pixel intensity nonuniformity , 1996, Journal of magnetic resonance imaging : JMRI.

[13]  Scott T. Grafton,et al.  Automated image registration: I. General methods and intrasubject, intramodality validation. , 1998, Journal of computer assisted tomography.

[14]  S. C. Strother,et al.  Multidimensional state-spaces for fMRI and PET activation studies , 1996, NeuroImage.

[15]  Jullie W Pan,et al.  High frequency volume coils for clinical NMR imaging and spectroscopy , 1994, Magnetic resonance in medicine.

[16]  Michael B. Smith,et al.  A method to create an optimum current distribution and homogeneous B1 field for elliptical birdcage coils , 1997, Magnetic resonance in medicine.

[17]  Alan C. Evans,et al.  A Comparison of Retrospective Intensity Non-uniformity Correction Methods for MRI , 1997, IPMI.

[18]  G. Bruce Pike,et al.  Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI , 1998, IEEE Transactions on Medical Imaging.

[19]  J. Schenck,et al.  An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T , 1985 .

[20]  David A. Rottenberg,et al.  Semi-automated stripping of T1 MRI volumes: I. Consensus of intensity-and edge-based methods , 1999 .