Crack Monitoring Method for an FRP-Strengthened Steel Structure Based on an Antenna Sensor

Fiber-reinforced polymer (FRP) has been increasingly applied to steel structures for structural strengthening or crack repair, given its high strength-to-weight ratio and high stiffness-to-weight ratio. Cracks in steel structures are the dominant hidden threats to structural safety. However, it is difficult to monitor structural cracks under FRP coverage and there is little related research. In this paper, a crack monitoring method for an FRP-strengthened steel structure deploying a microstrip antenna sensor is presented. A theoretical model of the dual-substrate antenna sensor with FRP is established and the sensitivity of crack monitoring is studied. The effects of the weak conductivity of carbon fiber reinforced polymers (CFRPs) on the performance of crack monitoring are analyzed via contrast experiments. The effects of FRP thickness on the performance of the antenna sensor are studied. The influence of structural strain on crack detection coupling is studied through strain–crack coupling experiments. The results indicate that the antenna sensor can detect cracks in steel structures covered by FRP (including CFRP). FRP thickness affects the antenna sensor’s performance significantly, while the effects of strain can be ignored. The results provide a new approach for crack monitoring of FRP-strengthened steel structures with extensive application prospects.

[1]  Haiying Huang,et al.  Detecting crack orientation using patch antenna sensors , 2011 .

[2]  X. Zhao,et al.  Boundary element analysis of edge cracked steel plates strengthened by CFRP laminates , 2016 .

[3]  Haiying Huang,et al.  Monitoring fatigue crack growth and opening using antenna sensors , 2010 .

[4]  Martin Schulze,et al.  A Smart Eddy Current Sensor Dedicated to the Nondestructive Evaluation of Carbon Fibers Reinforced Polymers , 2017, Sensors.

[5]  Haiying Huang,et al.  An Antenna Sensor for Crack Detection and Monitoring , 2011 .

[6]  Xiaohui Liu,et al.  Development of an FBG Sensor Array for Multi-Impact Source Localization on CFRP Structures , 2016, Sensors.

[7]  Gao Ma,et al.  Acoustic emission monitoring and damage assessment of FRP-strengthened reinforced concrete columns under cyclic loading , 2017 .

[8]  H.-H. Huang,et al.  Detecting crack orientation using antenna sensors , 2011, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[9]  Manos M. Tentzeris,et al.  Crack Detection and Monitoring Using Passive Wireless Sensor , 2009 .

[10]  Yang Wang,et al.  Battery-free slotted patch antenna sensor for wireless strain and crack monitoring , 2016 .

[11]  Manos M. Tentzeris,et al.  Passive low-cost inkjet-printed smart skin sensor for structural health monitoring , 2012 .

[12]  Xiang Ren,et al.  Development of a strain measurement method utilizing a rectangular microstrip patch antenna , 2016 .

[13]  H. A. Wheeler Transmission-Line Properties of Parallel Wide Strips by a Conformal-Mapping Approximation , 1964 .

[14]  Yang Wang,et al.  Thickness variation study of RFID-based folded patch antennas for strain sensing , 2011, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[15]  R. Haghani,et al.  Effects of moisture on the long-term performance of adhesively bonded FRP/steel joints used in bridges , 2016 .

[16]  Manotosh Biswas,et al.  Design and development of rectangular patch antenna with superstrates for the application in portable wireless equipments and aircraft radome , 2014 .

[17]  Gangbing Song,et al.  Concrete Infill Monitoring in Concrete-Filled FRP Tubes Using a PZT-Based Ultrasonic Time-of-Flight Method , 2016, Sensors.

[18]  Pierluigi Colombi,et al.  Fatigue crack growth in steel beams strengthened by CFRP strips , 2016 .

[19]  Xiaoli Jiang,et al.  Method for detecting damage in carbon-fibre reinforced plastic-steel structures based on eddy current pulsed thermography , 2018 .

[20]  Zhishen Wu,et al.  Distributed Long-Gauge Optical Fiber Sensors Based Self-Sensing FRP Bar for Concrete Structure , 2016, Sensors.

[21]  P. Paultre,et al.  Compressive behavior of FRP-confined reinforced concrete columns , 2017 .

[22]  Yang Wang,et al.  Passive wireless antenna sensor for strain and crack sensing—electromagnetic modeling, simulation, and testing , 2013 .

[23]  Binbin Li,et al.  A crack monitoring method based on microstrip patch antenna , 2015, 2015 Annual Reliability and Maintainability Symposium (RAMS).

[24]  Yang Wang,et al.  Thermal effects on a passive wireless antenna sensor for strain and crack sensing , 2012, Smart Structures.

[25]  P. Colombi,et al.  Fatigue crack growth in CFRP-strengthened steel plates , 2015 .