Automated selection of major arteries and veins for measurement of arteriolar-to-venular diameter ratio on retinal fundus images

An automated method for measurement of arteriolar-to-venular diameter ratio (AVR) is presented. The method includes optic disc segmentation for the determination of the AVR measurement zone, retinal vessel segmentation, vessel classification into arteries and veins, selection of major vessel pairs, and measurement of AVRs. The sensitivity for the major vessels in the measurement zone was 87%, while 93% of them were classified correctly into arteries or veins. In 36 out of 40 vessel pairs, at least parts of the paired vessels were correctly identified. Although the average error in the AVRs with respect to those based on the manual vessel segmentation results was 0.11, the average error in vessel diameter was less than 1 pixel. The proposed method may be useful for objective evaluation of AVRs and has a potential for detecting focal arteriolar narrowing on macula-centered screening fundus images.

[1]  Sandra C Fuchs,et al.  Measuring arteriolar-to-venous ratio in retinal photography of patients with hypertension: development and application of a new semi-automated method. , 2005, American journal of hypertension.

[2]  Peter Rockett An improved rotation-invariant thinning algorithm , 2005, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[3]  R. Klein,et al.  Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the Atherosclerosis Risk in Communities Study. , 1999, Ophthalmology.

[4]  Jiang Liu,et al.  Automatic Detection of Left and Right Eye in Retinal Fundus Images , 2009 .

[5]  R. Klein,et al.  Computer-assisted measurement of retinal vessel diameters in the Beaver Dam Eye Study: methodology, correlation between eyes, and effect of refractive errors. , 2004, Ophthalmology.

[6]  Hiroshi Fujita,et al.  Automated segmentation of optic disc region on retinal fundus photographs: Comparison of contour modeling and pixel classification methods , 2011, Comput. Methods Programs Biomed..

[7]  R. Klein,et al.  Revised formulas for summarizing retinal vessel diameters , 2003, Current eye research.

[8]  Max A. Viergever,et al.  Ridge-based vessel segmentation in color images of the retina , 2004, IEEE Transactions on Medical Imaging.

[9]  A. Ruggeri,et al.  An improved system for the automatic estimation of the Arteriolar-to-Venular diameter Ratio (AVR) in retinal images , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Xiaohong W. Gao,et al.  Quantification and characterisation of arteries in retinal images , 2000, Comput. Methods Programs Biomed..

[11]  Hum Chung,et al.  Automated measurement of retinal vessel diameters on digital fundus photographs , 2009 .

[12]  Bjarne K. Ersbøll,et al.  Quantitative measurement of changes in retinal vessel diameter in ocular fundus images , 2000, Pattern Recognit. Lett..

[13]  Hiroshi Fujita,et al.  Automated detection and classification of major retinal vessels for determination of diameter ratio of arteries and veins , 2010, Medical Imaging.

[14]  Alfredo Ruggeri,et al.  Computer estimation of the AVR parameter in diabetic retinopathy , 2009 .

[15]  J. Bisognano,et al.  The relationship between retinal microvascular abnormalities and coronary heart disease: a review. , 2010, The American journal of medicine.

[16]  R. Klein,et al.  Retinal microvascular abnormalities and incident stroke: the Atherosclerosis Risk in Communities Study , 2001, The Lancet.

[17]  Abdul Ghapor Hussin,et al.  Computerized Medical Imaging and Graphics. , 2011 .

[18]  Hiroshi Fujita,et al.  Quantitative depth analysis of optic nerve head using stereo retinal fundus image pair. , 2008, Journal of biomedical optics.

[19]  Bram van Ginneken,et al.  Automatic determination of the artery vein ratio in retinal images , 2010, Medical Imaging.