A. Feydy | H. Guérini | E. Pessis | R. Campagna | J. Sverzut | J. Drapé
[1] Francesco C Stingo,et al. An evaluation of three commercially available metal artifact reduction methods for CT imaging , 2015, Physics in medicine and biology.
[2] Yong Eun Chung,et al. Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility. , 2014, AJR. American journal of roentgenology.
[3] A. Blum,et al. Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures , 2014, Skeletal Radiology.
[4] Yang Wang,et al. Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis. , 2013, European journal of radiology.
[5] A. Feydy,et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT. , 2013, Radiographics : a review publication of the Radiological Society of North America, Inc.
[6] Shuai Leng,et al. Dual-energy CT-based monochromatic imaging. , 2012, AJR. American journal of roentgenology.
[7] Alexander Brook,et al. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers. , 2012, Radiology.
[8] Richard H Cohan,et al. Dual-energy CT with single- and dual-source scanners: current applications in evaluating the genitourinary tract. , 2012, Radiographics : a review publication of the Radiological Society of North America, Inc.
[9] Jin-Suck Suh,et al. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software , 2012, European Radiology.
[10] C. McCollough,et al. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. , 2011, Medical physics.
[11] Alvin C. Silva,et al. Dual-energy (spectral) CT: applications in abdominal imaging. , 2011, Radiographics : a review publication of the Radiological Society of North America, Inc.
[12] Jiang Hsieh,et al. Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching. , 2011, Medical physics.
[13] Sachio Kuribayashi,et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. , 2011, Radiology.
[14] Xinhua Li,et al. Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. , 2011, Medical physics.
[15] Konstantin Nikolaou,et al. Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.
[16] Robert G. Paden,et al. Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress , 2009, Skeletal Radiology.
[17] Yong-Min Huh,et al. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.
[18] Kenneth A Buckwalter,et al. Multichannel CT: evaluating the spine in postoperative patients with orthopedic hardware. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.
[19] Julia F. Barrett,et al. Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.
[20] P. Taourel,et al. Painful infection at the site of hip prosthesis: CT imaging. , 2002, Radiology.